Vibroacoustic stimulation for risk assessment

Research output: Contribution to journalReview article

7 Citations (Scopus)

Abstract

VAS of the human fetus produces a profound alteration of fetal behavior and FHR. Many authors have reported on the success of the technique in improving the efficiency of antepartum FHR testing without altering the predictive reliability of the tests. VAS has other potential advantages in the antepartum assessment of fetal well-being and provocation of fetal activity to improve ultrasonographic anatomic visualization. Experimentally, VAS offers a unique opportunity to assess how the fetus responds to its external environment. The information currently available suggests that exposure of the fetus to VAS is safe in its present clinical applications. Additional investigation is needed to characterize the best frequency, duration, intensity, and choice of stimulus to provide the most consistent responses. The literature to date presents a confusing array of studies that have used different methodologies, making comparisons of studies difficult. It is the opinion of the author that VAS is a safe clinical technique as currently employed.

Original languageEnglish (US)
Pages (from-to)797-808
Number of pages12
JournalClinics in Perinatology
Volume21
Issue number4
StatePublished - Dec 1 1994

Fingerprint

Fetus
Fetal Movement

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health

Cite this

Vibroacoustic stimulation for risk assessment. / Smith, Carl Vernon.

In: Clinics in Perinatology, Vol. 21, No. 4, 01.12.1994, p. 797-808.

Research output: Contribution to journalReview article

@article{747b5d0eb1294a05b9ecaa08097ed5f3,
title = "Vibroacoustic stimulation for risk assessment",
abstract = "VAS of the human fetus produces a profound alteration of fetal behavior and FHR. Many authors have reported on the success of the technique in improving the efficiency of antepartum FHR testing without altering the predictive reliability of the tests. VAS has other potential advantages in the antepartum assessment of fetal well-being and provocation of fetal activity to improve ultrasonographic anatomic visualization. Experimentally, VAS offers a unique opportunity to assess how the fetus responds to its external environment. The information currently available suggests that exposure of the fetus to VAS is safe in its present clinical applications. Additional investigation is needed to characterize the best frequency, duration, intensity, and choice of stimulus to provide the most consistent responses. The literature to date presents a confusing array of studies that have used different methodologies, making comparisons of studies difficult. It is the opinion of the author that VAS is a safe clinical technique as currently employed.",
author = "Smith, {Carl Vernon}",
year = "1994",
month = "12",
day = "1",
language = "English (US)",
volume = "21",
pages = "797--808",
journal = "Clinics in Perinatology",
issn = "0095-5108",
publisher = "W.B. Saunders Ltd",
number = "4",

}

TY - JOUR

T1 - Vibroacoustic stimulation for risk assessment

AU - Smith, Carl Vernon

PY - 1994/12/1

Y1 - 1994/12/1

N2 - VAS of the human fetus produces a profound alteration of fetal behavior and FHR. Many authors have reported on the success of the technique in improving the efficiency of antepartum FHR testing without altering the predictive reliability of the tests. VAS has other potential advantages in the antepartum assessment of fetal well-being and provocation of fetal activity to improve ultrasonographic anatomic visualization. Experimentally, VAS offers a unique opportunity to assess how the fetus responds to its external environment. The information currently available suggests that exposure of the fetus to VAS is safe in its present clinical applications. Additional investigation is needed to characterize the best frequency, duration, intensity, and choice of stimulus to provide the most consistent responses. The literature to date presents a confusing array of studies that have used different methodologies, making comparisons of studies difficult. It is the opinion of the author that VAS is a safe clinical technique as currently employed.

AB - VAS of the human fetus produces a profound alteration of fetal behavior and FHR. Many authors have reported on the success of the technique in improving the efficiency of antepartum FHR testing without altering the predictive reliability of the tests. VAS has other potential advantages in the antepartum assessment of fetal well-being and provocation of fetal activity to improve ultrasonographic anatomic visualization. Experimentally, VAS offers a unique opportunity to assess how the fetus responds to its external environment. The information currently available suggests that exposure of the fetus to VAS is safe in its present clinical applications. Additional investigation is needed to characterize the best frequency, duration, intensity, and choice of stimulus to provide the most consistent responses. The literature to date presents a confusing array of studies that have used different methodologies, making comparisons of studies difficult. It is the opinion of the author that VAS is a safe clinical technique as currently employed.

UR - http://www.scopus.com/inward/record.url?scp=0028630736&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028630736&partnerID=8YFLogxK

M3 - Review article

C2 - 7882644

AN - SCOPUS:0028630736

VL - 21

SP - 797

EP - 808

JO - Clinics in Perinatology

JF - Clinics in Perinatology

SN - 0095-5108

IS - 4

ER -