Validation of use of annular once-punched filter paper bloodspot samples for repeat lead testing

Dana F. El-Hajjar, Katherine H. Swanson, James D. Landmark, Douglas F. Stickle

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Background: Lack of a second sample often precludes the ability to perform repeat lead measurements on filter paper bloodspot samples. We investigated whether annular specimens remaining from once-punched filter paper bloodspot specimens could provide accurate Pb measurements when measurements were scaled for the remainder area relative to the original punch area. Methods: 50 μl bloodspot specimens were prepared using Pb-spiked EDTA whole blood. After removal of 6 mm punches, bitmap images of the remainder specimens were obtained using a scanner. Image analysis was used to determine the bloodspot area of the remainder sample relative to the area of the original punch. Measurement of Pb for punches and for remainder specimens was performed by ICP-MS. Results: Area-corrected Pb measurements for remainder samples were significantly higher than for the punches, by an average factor of 1.52 ± 0.12 (p < 0.05, n = 28). The difference was due to a discontinuity (an increase) in the per-area Pb at the bloodspot perimeter. Area-corrected results for annular specimens that excluded the perimeter were identical to those of the punch. Conclusion: Area-corrected Pb measurement using annular once-punched bloodspot remainder specimens can accurately reproduce lead measurements obtained from the original punch when the bloodspot perimeter area is excluded.

Original languageEnglish (US)
Pages (from-to)179-184
Number of pages6
JournalClinica Chimica Acta
Volume377
Issue number1-2
DOIs
StatePublished - Feb 2 2007

Fingerprint

Testing
Edetic Acid
Lead
Image analysis
Blood

Keywords

  • Bloodspot
  • Filter paper
  • ICP-MS
  • Lead

ASJC Scopus subject areas

  • Biochemistry
  • Clinical Biochemistry
  • Biochemistry, medical

Cite this

Validation of use of annular once-punched filter paper bloodspot samples for repeat lead testing. / El-Hajjar, Dana F.; Swanson, Katherine H.; Landmark, James D.; Stickle, Douglas F.

In: Clinica Chimica Acta, Vol. 377, No. 1-2, 02.02.2007, p. 179-184.

Research output: Contribution to journalArticle

El-Hajjar, Dana F. ; Swanson, Katherine H. ; Landmark, James D. ; Stickle, Douglas F. / Validation of use of annular once-punched filter paper bloodspot samples for repeat lead testing. In: Clinica Chimica Acta. 2007 ; Vol. 377, No. 1-2. pp. 179-184.
@article{c8a7111e456c4a35b0591f2e13db1747,
title = "Validation of use of annular once-punched filter paper bloodspot samples for repeat lead testing",
abstract = "Background: Lack of a second sample often precludes the ability to perform repeat lead measurements on filter paper bloodspot samples. We investigated whether annular specimens remaining from once-punched filter paper bloodspot specimens could provide accurate Pb measurements when measurements were scaled for the remainder area relative to the original punch area. Methods: 50 μl bloodspot specimens were prepared using Pb-spiked EDTA whole blood. After removal of 6 mm punches, bitmap images of the remainder specimens were obtained using a scanner. Image analysis was used to determine the bloodspot area of the remainder sample relative to the area of the original punch. Measurement of Pb for punches and for remainder specimens was performed by ICP-MS. Results: Area-corrected Pb measurements for remainder samples were significantly higher than for the punches, by an average factor of 1.52 ± 0.12 (p < 0.05, n = 28). The difference was due to a discontinuity (an increase) in the per-area Pb at the bloodspot perimeter. Area-corrected results for annular specimens that excluded the perimeter were identical to those of the punch. Conclusion: Area-corrected Pb measurement using annular once-punched bloodspot remainder specimens can accurately reproduce lead measurements obtained from the original punch when the bloodspot perimeter area is excluded.",
keywords = "Bloodspot, Filter paper, ICP-MS, Lead",
author = "El-Hajjar, {Dana F.} and Swanson, {Katherine H.} and Landmark, {James D.} and Stickle, {Douglas F.}",
year = "2007",
month = "2",
day = "2",
doi = "10.1016/j.cca.2006.09.020",
language = "English (US)",
volume = "377",
pages = "179--184",
journal = "Clinica Chimica Acta",
issn = "0009-8981",
publisher = "Elsevier",
number = "1-2",

}

TY - JOUR

T1 - Validation of use of annular once-punched filter paper bloodspot samples for repeat lead testing

AU - El-Hajjar, Dana F.

AU - Swanson, Katherine H.

AU - Landmark, James D.

AU - Stickle, Douglas F.

PY - 2007/2/2

Y1 - 2007/2/2

N2 - Background: Lack of a second sample often precludes the ability to perform repeat lead measurements on filter paper bloodspot samples. We investigated whether annular specimens remaining from once-punched filter paper bloodspot specimens could provide accurate Pb measurements when measurements were scaled for the remainder area relative to the original punch area. Methods: 50 μl bloodspot specimens were prepared using Pb-spiked EDTA whole blood. After removal of 6 mm punches, bitmap images of the remainder specimens were obtained using a scanner. Image analysis was used to determine the bloodspot area of the remainder sample relative to the area of the original punch. Measurement of Pb for punches and for remainder specimens was performed by ICP-MS. Results: Area-corrected Pb measurements for remainder samples were significantly higher than for the punches, by an average factor of 1.52 ± 0.12 (p < 0.05, n = 28). The difference was due to a discontinuity (an increase) in the per-area Pb at the bloodspot perimeter. Area-corrected results for annular specimens that excluded the perimeter were identical to those of the punch. Conclusion: Area-corrected Pb measurement using annular once-punched bloodspot remainder specimens can accurately reproduce lead measurements obtained from the original punch when the bloodspot perimeter area is excluded.

AB - Background: Lack of a second sample often precludes the ability to perform repeat lead measurements on filter paper bloodspot samples. We investigated whether annular specimens remaining from once-punched filter paper bloodspot specimens could provide accurate Pb measurements when measurements were scaled for the remainder area relative to the original punch area. Methods: 50 μl bloodspot specimens were prepared using Pb-spiked EDTA whole blood. After removal of 6 mm punches, bitmap images of the remainder specimens were obtained using a scanner. Image analysis was used to determine the bloodspot area of the remainder sample relative to the area of the original punch. Measurement of Pb for punches and for remainder specimens was performed by ICP-MS. Results: Area-corrected Pb measurements for remainder samples were significantly higher than for the punches, by an average factor of 1.52 ± 0.12 (p < 0.05, n = 28). The difference was due to a discontinuity (an increase) in the per-area Pb at the bloodspot perimeter. Area-corrected results for annular specimens that excluded the perimeter were identical to those of the punch. Conclusion: Area-corrected Pb measurement using annular once-punched bloodspot remainder specimens can accurately reproduce lead measurements obtained from the original punch when the bloodspot perimeter area is excluded.

KW - Bloodspot

KW - Filter paper

KW - ICP-MS

KW - Lead

UR - http://www.scopus.com/inward/record.url?scp=33845496764&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845496764&partnerID=8YFLogxK

U2 - 10.1016/j.cca.2006.09.020

DO - 10.1016/j.cca.2006.09.020

M3 - Article

C2 - 17078940

AN - SCOPUS:33845496764

VL - 377

SP - 179

EP - 184

JO - Clinica Chimica Acta

JF - Clinica Chimica Acta

SN - 0009-8981

IS - 1-2

ER -