Transthoracic Intracardiac Monitoring Lines in Pediatric Surgical Patients

A Ten-Year Experience

Jeffrey P Gold, Richard A. Jonas, Peter Lang, E. Marsha Elixson, John E. Mayer, Aldo R. Castaneda

Research output: Contribution to journalArticle

59 Citations (Scopus)

Abstract

A study of 6,690 transthoracic intracardiac monitoring (TIM) catheters in 5,666 pediatric patients undergoing cardiac surgical procedures during a 10-year period demonstrates the safety of this monitoring method. The utility of TIM catheters in patients undergoing a modified Fontan procedure, those undergoing repair of tetralogy of Fallot, and those with elevated or labile pulmonary resistance is stressed. Right atrial (RA) and left atrial (LA) catheters are particularly safe; they have a low incidence of bleeding complications (RA = 0%, LA = 0.13%) and retention complications (RA = 0.15%, LA = 0.63%). Pulmonary artery (PA) catheters that are introduced through the right ventricular infundibulum have higher complication rates (1.07%); unpredictable hemodynamic compromise occurs in approximately 0.5% of such patients. PA catheters placed through the wall of the atrium have a lower complication rate—approximately equal to that for RA and LA catheters. The benefits of TIM catheters far outweigh the associated risks if care is exercised in placing and removing them, and if complications are rapidly recognized and aggressively managed. The continued use of TIM catheters in pediatric cardiac surgical patients is therefore strongly recommended.

Original languageEnglish (US)
Pages (from-to)185-191
Number of pages7
JournalAnnals of Thoracic Surgery
Volume42
Issue number2
DOIs
StatePublished - Jan 1 1986

Fingerprint

Cardiac Catheters
Catheters
Pediatrics
Pulmonary Artery
Cardiac Surgical Procedures
Fontan Procedure
Tetralogy of Fallot
Pituitary Gland
Hemodynamics
Hemorrhage
Safety
Lung
Incidence

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Cite this

Transthoracic Intracardiac Monitoring Lines in Pediatric Surgical Patients : A Ten-Year Experience. / Gold, Jeffrey P; Jonas, Richard A.; Lang, Peter; Elixson, E. Marsha; Mayer, John E.; Castaneda, Aldo R.

In: Annals of Thoracic Surgery, Vol. 42, No. 2, 01.01.1986, p. 185-191.

Research output: Contribution to journalArticle

Gold, Jeffrey P ; Jonas, Richard A. ; Lang, Peter ; Elixson, E. Marsha ; Mayer, John E. ; Castaneda, Aldo R. / Transthoracic Intracardiac Monitoring Lines in Pediatric Surgical Patients : A Ten-Year Experience. In: Annals of Thoracic Surgery. 1986 ; Vol. 42, No. 2. pp. 185-191.
@article{30bb32904714447c9b7e133470288ac2,
title = "Transthoracic Intracardiac Monitoring Lines in Pediatric Surgical Patients: A Ten-Year Experience",
abstract = "A study of 6,690 transthoracic intracardiac monitoring (TIM) catheters in 5,666 pediatric patients undergoing cardiac surgical procedures during a 10-year period demonstrates the safety of this monitoring method. The utility of TIM catheters in patients undergoing a modified Fontan procedure, those undergoing repair of tetralogy of Fallot, and those with elevated or labile pulmonary resistance is stressed. Right atrial (RA) and left atrial (LA) catheters are particularly safe; they have a low incidence of bleeding complications (RA = 0{\%}, LA = 0.13{\%}) and retention complications (RA = 0.15{\%}, LA = 0.63{\%}). Pulmonary artery (PA) catheters that are introduced through the right ventricular infundibulum have higher complication rates (1.07{\%}); unpredictable hemodynamic compromise occurs in approximately 0.5{\%} of such patients. PA catheters placed through the wall of the atrium have a lower complication rate—approximately equal to that for RA and LA catheters. The benefits of TIM catheters far outweigh the associated risks if care is exercised in placing and removing them, and if complications are rapidly recognized and aggressively managed. The continued use of TIM catheters in pediatric cardiac surgical patients is therefore strongly recommended.",
author = "Gold, {Jeffrey P} and Jonas, {Richard A.} and Peter Lang and Elixson, {E. Marsha} and Mayer, {John E.} and Castaneda, {Aldo R.}",
year = "1986",
month = "1",
day = "1",
doi = "10.1016/S0003-4975(10)60515-2",
language = "English (US)",
volume = "42",
pages = "185--191",
journal = "Annals of Thoracic Surgery",
issn = "0003-4975",
publisher = "Elsevier USA",
number = "2",

}

TY - JOUR

T1 - Transthoracic Intracardiac Monitoring Lines in Pediatric Surgical Patients

T2 - A Ten-Year Experience

AU - Gold, Jeffrey P

AU - Jonas, Richard A.

AU - Lang, Peter

AU - Elixson, E. Marsha

AU - Mayer, John E.

AU - Castaneda, Aldo R.

PY - 1986/1/1

Y1 - 1986/1/1

N2 - A study of 6,690 transthoracic intracardiac monitoring (TIM) catheters in 5,666 pediatric patients undergoing cardiac surgical procedures during a 10-year period demonstrates the safety of this monitoring method. The utility of TIM catheters in patients undergoing a modified Fontan procedure, those undergoing repair of tetralogy of Fallot, and those with elevated or labile pulmonary resistance is stressed. Right atrial (RA) and left atrial (LA) catheters are particularly safe; they have a low incidence of bleeding complications (RA = 0%, LA = 0.13%) and retention complications (RA = 0.15%, LA = 0.63%). Pulmonary artery (PA) catheters that are introduced through the right ventricular infundibulum have higher complication rates (1.07%); unpredictable hemodynamic compromise occurs in approximately 0.5% of such patients. PA catheters placed through the wall of the atrium have a lower complication rate—approximately equal to that for RA and LA catheters. The benefits of TIM catheters far outweigh the associated risks if care is exercised in placing and removing them, and if complications are rapidly recognized and aggressively managed. The continued use of TIM catheters in pediatric cardiac surgical patients is therefore strongly recommended.

AB - A study of 6,690 transthoracic intracardiac monitoring (TIM) catheters in 5,666 pediatric patients undergoing cardiac surgical procedures during a 10-year period demonstrates the safety of this monitoring method. The utility of TIM catheters in patients undergoing a modified Fontan procedure, those undergoing repair of tetralogy of Fallot, and those with elevated or labile pulmonary resistance is stressed. Right atrial (RA) and left atrial (LA) catheters are particularly safe; they have a low incidence of bleeding complications (RA = 0%, LA = 0.13%) and retention complications (RA = 0.15%, LA = 0.63%). Pulmonary artery (PA) catheters that are introduced through the right ventricular infundibulum have higher complication rates (1.07%); unpredictable hemodynamic compromise occurs in approximately 0.5% of such patients. PA catheters placed through the wall of the atrium have a lower complication rate—approximately equal to that for RA and LA catheters. The benefits of TIM catheters far outweigh the associated risks if care is exercised in placing and removing them, and if complications are rapidly recognized and aggressively managed. The continued use of TIM catheters in pediatric cardiac surgical patients is therefore strongly recommended.

UR - http://www.scopus.com/inward/record.url?scp=0022449944&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022449944&partnerID=8YFLogxK

U2 - 10.1016/S0003-4975(10)60515-2

DO - 10.1016/S0003-4975(10)60515-2

M3 - Article

VL - 42

SP - 185

EP - 191

JO - Annals of Thoracic Surgery

JF - Annals of Thoracic Surgery

SN - 0003-4975

IS - 2

ER -