Towards understanding the limits of distortion product otoacoustic emission measurements

Michael P Gorga, Stephen T Neely, B. M. Bergman, K. L. Beauchaine, J. R. Kaminski, Z. Liu

Research output: Contribution to journalArticle

46 Citations (Scopus)

Abstract

Distortion product otoacoustic emission (DPOAE) data were obtained with a custom-designed system from 20 subjects with normal hearing. Cavity measurements, using this system and an Etymotic ER-10B lownoise microphone system, resulted in estimates of recording system distortion of 20 dB SPL for f2 frequencies ranging from 500 to 8000 Hz, and primary levels ranging from 20 to 75 dB SPL (L2=L1 10 dB). Using this system it was possible to automatically adjust averaging time in order to obtain the same residual noise levels across frequencies. In all subjects with normal hearing, DPOAEs were measurable over a wide range of primary levels for octave f2 frequencies from 1000 to 8000 Hz, but not at 500 Hz. At 500 Hz, only half of the normalhearing subjects produced DPOAEs that were above the noise floor. When they did, DPOAE amplitude was less than that observed at higher f2 frequencies. While the cause for response absence in some normal ears may have been due to residual noise, the reduced amplitude suggests that the other factors influence the measurement of DPOAEs at low frequencies. This result may be due to reduced cochlear production of DPOAEs at lower frequencies or reduced transmission through the middle ear.

Original languageEnglish (US)
Pages (from-to)1494-1500
Number of pages7
JournalJournal of the Acoustical Society of America
Volume96
Issue number3
DOIs
StatePublished - Sep 1994

Fingerprint

hearing
products
middle ear
low frequencies
octaves
ear
microphones
recording
cavities
causes
estimates
Hearing

ASJC Scopus subject areas

  • Arts and Humanities (miscellaneous)
  • Acoustics and Ultrasonics

Cite this

Towards understanding the limits of distortion product otoacoustic emission measurements. / Gorga, Michael P; Neely, Stephen T; Bergman, B. M.; Beauchaine, K. L.; Kaminski, J. R.; Liu, Z.

In: Journal of the Acoustical Society of America, Vol. 96, No. 3, 09.1994, p. 1494-1500.

Research output: Contribution to journalArticle

Gorga, Michael P ; Neely, Stephen T ; Bergman, B. M. ; Beauchaine, K. L. ; Kaminski, J. R. ; Liu, Z. / Towards understanding the limits of distortion product otoacoustic emission measurements. In: Journal of the Acoustical Society of America. 1994 ; Vol. 96, No. 3. pp. 1494-1500.
@article{35a822c05b0442f08b20f8428f77a0b5,
title = "Towards understanding the limits of distortion product otoacoustic emission measurements",
abstract = "Distortion product otoacoustic emission (DPOAE) data were obtained with a custom-designed system from 20 subjects with normal hearing. Cavity measurements, using this system and an Etymotic ER-10B lownoise microphone system, resulted in estimates of recording system distortion of 20 dB SPL for f2 frequencies ranging from 500 to 8000 Hz, and primary levels ranging from 20 to 75 dB SPL (L2=L1 10 dB). Using this system it was possible to automatically adjust averaging time in order to obtain the same residual noise levels across frequencies. In all subjects with normal hearing, DPOAEs were measurable over a wide range of primary levels for octave f2 frequencies from 1000 to 8000 Hz, but not at 500 Hz. At 500 Hz, only half of the normalhearing subjects produced DPOAEs that were above the noise floor. When they did, DPOAE amplitude was less than that observed at higher f2 frequencies. While the cause for response absence in some normal ears may have been due to residual noise, the reduced amplitude suggests that the other factors influence the measurement of DPOAEs at low frequencies. This result may be due to reduced cochlear production of DPOAEs at lower frequencies or reduced transmission through the middle ear.",
author = "Gorga, {Michael P} and Neely, {Stephen T} and Bergman, {B. M.} and Beauchaine, {K. L.} and Kaminski, {J. R.} and Z. Liu",
year = "1994",
month = "9",
doi = "10.1121/1.410227",
language = "English (US)",
volume = "96",
pages = "1494--1500",
journal = "Journal of the Acoustical Society of America",
issn = "0001-4966",
publisher = "Acoustical Society of America",
number = "3",

}

TY - JOUR

T1 - Towards understanding the limits of distortion product otoacoustic emission measurements

AU - Gorga, Michael P

AU - Neely, Stephen T

AU - Bergman, B. M.

AU - Beauchaine, K. L.

AU - Kaminski, J. R.

AU - Liu, Z.

PY - 1994/9

Y1 - 1994/9

N2 - Distortion product otoacoustic emission (DPOAE) data were obtained with a custom-designed system from 20 subjects with normal hearing. Cavity measurements, using this system and an Etymotic ER-10B lownoise microphone system, resulted in estimates of recording system distortion of 20 dB SPL for f2 frequencies ranging from 500 to 8000 Hz, and primary levels ranging from 20 to 75 dB SPL (L2=L1 10 dB). Using this system it was possible to automatically adjust averaging time in order to obtain the same residual noise levels across frequencies. In all subjects with normal hearing, DPOAEs were measurable over a wide range of primary levels for octave f2 frequencies from 1000 to 8000 Hz, but not at 500 Hz. At 500 Hz, only half of the normalhearing subjects produced DPOAEs that were above the noise floor. When they did, DPOAE amplitude was less than that observed at higher f2 frequencies. While the cause for response absence in some normal ears may have been due to residual noise, the reduced amplitude suggests that the other factors influence the measurement of DPOAEs at low frequencies. This result may be due to reduced cochlear production of DPOAEs at lower frequencies or reduced transmission through the middle ear.

AB - Distortion product otoacoustic emission (DPOAE) data were obtained with a custom-designed system from 20 subjects with normal hearing. Cavity measurements, using this system and an Etymotic ER-10B lownoise microphone system, resulted in estimates of recording system distortion of 20 dB SPL for f2 frequencies ranging from 500 to 8000 Hz, and primary levels ranging from 20 to 75 dB SPL (L2=L1 10 dB). Using this system it was possible to automatically adjust averaging time in order to obtain the same residual noise levels across frequencies. In all subjects with normal hearing, DPOAEs were measurable over a wide range of primary levels for octave f2 frequencies from 1000 to 8000 Hz, but not at 500 Hz. At 500 Hz, only half of the normalhearing subjects produced DPOAEs that were above the noise floor. When they did, DPOAE amplitude was less than that observed at higher f2 frequencies. While the cause for response absence in some normal ears may have been due to residual noise, the reduced amplitude suggests that the other factors influence the measurement of DPOAEs at low frequencies. This result may be due to reduced cochlear production of DPOAEs at lower frequencies or reduced transmission through the middle ear.

UR - http://www.scopus.com/inward/record.url?scp=0027932774&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027932774&partnerID=8YFLogxK

U2 - 10.1121/1.410227

DO - 10.1121/1.410227

M3 - Article

C2 - 7963014

AN - SCOPUS:0027932774

VL - 96

SP - 1494

EP - 1500

JO - Journal of the Acoustical Society of America

JF - Journal of the Acoustical Society of America

SN - 0001-4966

IS - 3

ER -