Thrombolytic enhancement with perfluorocarbon-exposed sonicated dextrose albumin microbubbles

Thomas Richard Porter, Robert F. LeVeen, Randy Fox, Alan Kricsfeld, Feng Xie

Research output: Contribution to journalArticle

132 Citations (Scopus)

Abstract

Whereas low-intensity, high-frequency ultrasound (US) alone appears to cause minimal thrombolysis, US combined with air-filled microbubbles does increase the amount of urokinase (UK)-mediated clot lysis (CL). Because this phenomenon may be mediated by cavitation-induced streaming, we hypothesized that perfluorocarbon-exposed sonicated dextrose albumin (PESDA) microbubbles, which are more stable than air-filled microbubbles, may also enhance US- induced thrombolysis. We measured the percentage CL of equally sized thrombi (1.0 ± 0.1 mg) made from freshly drawn blood incubated for 2 hours and then exposed to 20 kHz US (0.846 MPa peak negative pressure). The thrombi were bathed in 4 ml of saline solution, UK alone (20,000 U), PESDA alone, or a combination of PESDA with UK. The percentage CL achieved with PESDA and therapeutic US was also compared with the percentage CL achieved with room air-filled sonicated dextrose albumin (RASDA) microbubbles. When compared with US alone (24% ± 13% CL) or UK alone (17% ± 3% CL), PESDA plus US produced significantly better CL (43% ± 17%; p < 0.05). PESDA combined with US also produced significantly greater CL than RASDA combined with US (28% ± 9%; p < 0.05). The optimal CL was achieved with a combination of PESDA with UK with US (60% ± 14% CL). We conclude that PESDA microbubbles alone may be capable of inducing thrombolysis when insonified with a low-frequency transducer.

Original languageEnglish (US)
Pages (from-to)964-968
Number of pages5
JournalAmerican Heart Journal
Volume132
Issue number5
DOIs
StatePublished - Jan 1 1996

Fingerprint

Fluorocarbons
Microbubbles
Albumins
Glucose
Urokinase-Type Plasminogen Activator
Air
Thrombosis
Transducers
Sodium Chloride

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Thrombolytic enhancement with perfluorocarbon-exposed sonicated dextrose albumin microbubbles. / Porter, Thomas Richard; LeVeen, Robert F.; Fox, Randy; Kricsfeld, Alan; Xie, Feng.

In: American Heart Journal, Vol. 132, No. 5, 01.01.1996, p. 964-968.

Research output: Contribution to journalArticle

@article{bb071e8ec35a4e26898df71ffbd251e1,
title = "Thrombolytic enhancement with perfluorocarbon-exposed sonicated dextrose albumin microbubbles",
abstract = "Whereas low-intensity, high-frequency ultrasound (US) alone appears to cause minimal thrombolysis, US combined with air-filled microbubbles does increase the amount of urokinase (UK)-mediated clot lysis (CL). Because this phenomenon may be mediated by cavitation-induced streaming, we hypothesized that perfluorocarbon-exposed sonicated dextrose albumin (PESDA) microbubbles, which are more stable than air-filled microbubbles, may also enhance US- induced thrombolysis. We measured the percentage CL of equally sized thrombi (1.0 ± 0.1 mg) made from freshly drawn blood incubated for 2 hours and then exposed to 20 kHz US (0.846 MPa peak negative pressure). The thrombi were bathed in 4 ml of saline solution, UK alone (20,000 U), PESDA alone, or a combination of PESDA with UK. The percentage CL achieved with PESDA and therapeutic US was also compared with the percentage CL achieved with room air-filled sonicated dextrose albumin (RASDA) microbubbles. When compared with US alone (24{\%} ± 13{\%} CL) or UK alone (17{\%} ± 3{\%} CL), PESDA plus US produced significantly better CL (43{\%} ± 17{\%}; p < 0.05). PESDA combined with US also produced significantly greater CL than RASDA combined with US (28{\%} ± 9{\%}; p < 0.05). The optimal CL was achieved with a combination of PESDA with UK with US (60{\%} ± 14{\%} CL). We conclude that PESDA microbubbles alone may be capable of inducing thrombolysis when insonified with a low-frequency transducer.",
author = "Porter, {Thomas Richard} and LeVeen, {Robert F.} and Randy Fox and Alan Kricsfeld and Feng Xie",
year = "1996",
month = "1",
day = "1",
doi = "10.1016/S0002-8703(96)90006-X",
language = "English (US)",
volume = "132",
pages = "964--968",
journal = "American Heart Journal",
issn = "0002-8703",
publisher = "Mosby Inc.",
number = "5",

}

TY - JOUR

T1 - Thrombolytic enhancement with perfluorocarbon-exposed sonicated dextrose albumin microbubbles

AU - Porter, Thomas Richard

AU - LeVeen, Robert F.

AU - Fox, Randy

AU - Kricsfeld, Alan

AU - Xie, Feng

PY - 1996/1/1

Y1 - 1996/1/1

N2 - Whereas low-intensity, high-frequency ultrasound (US) alone appears to cause minimal thrombolysis, US combined with air-filled microbubbles does increase the amount of urokinase (UK)-mediated clot lysis (CL). Because this phenomenon may be mediated by cavitation-induced streaming, we hypothesized that perfluorocarbon-exposed sonicated dextrose albumin (PESDA) microbubbles, which are more stable than air-filled microbubbles, may also enhance US- induced thrombolysis. We measured the percentage CL of equally sized thrombi (1.0 ± 0.1 mg) made from freshly drawn blood incubated for 2 hours and then exposed to 20 kHz US (0.846 MPa peak negative pressure). The thrombi were bathed in 4 ml of saline solution, UK alone (20,000 U), PESDA alone, or a combination of PESDA with UK. The percentage CL achieved with PESDA and therapeutic US was also compared with the percentage CL achieved with room air-filled sonicated dextrose albumin (RASDA) microbubbles. When compared with US alone (24% ± 13% CL) or UK alone (17% ± 3% CL), PESDA plus US produced significantly better CL (43% ± 17%; p < 0.05). PESDA combined with US also produced significantly greater CL than RASDA combined with US (28% ± 9%; p < 0.05). The optimal CL was achieved with a combination of PESDA with UK with US (60% ± 14% CL). We conclude that PESDA microbubbles alone may be capable of inducing thrombolysis when insonified with a low-frequency transducer.

AB - Whereas low-intensity, high-frequency ultrasound (US) alone appears to cause minimal thrombolysis, US combined with air-filled microbubbles does increase the amount of urokinase (UK)-mediated clot lysis (CL). Because this phenomenon may be mediated by cavitation-induced streaming, we hypothesized that perfluorocarbon-exposed sonicated dextrose albumin (PESDA) microbubbles, which are more stable than air-filled microbubbles, may also enhance US- induced thrombolysis. We measured the percentage CL of equally sized thrombi (1.0 ± 0.1 mg) made from freshly drawn blood incubated for 2 hours and then exposed to 20 kHz US (0.846 MPa peak negative pressure). The thrombi were bathed in 4 ml of saline solution, UK alone (20,000 U), PESDA alone, or a combination of PESDA with UK. The percentage CL achieved with PESDA and therapeutic US was also compared with the percentage CL achieved with room air-filled sonicated dextrose albumin (RASDA) microbubbles. When compared with US alone (24% ± 13% CL) or UK alone (17% ± 3% CL), PESDA plus US produced significantly better CL (43% ± 17%; p < 0.05). PESDA combined with US also produced significantly greater CL than RASDA combined with US (28% ± 9%; p < 0.05). The optimal CL was achieved with a combination of PESDA with UK with US (60% ± 14% CL). We conclude that PESDA microbubbles alone may be capable of inducing thrombolysis when insonified with a low-frequency transducer.

UR - http://www.scopus.com/inward/record.url?scp=0029807006&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029807006&partnerID=8YFLogxK

U2 - 10.1016/S0002-8703(96)90006-X

DO - 10.1016/S0002-8703(96)90006-X

M3 - Article

C2 - 8892768

AN - SCOPUS:0029807006

VL - 132

SP - 964

EP - 968

JO - American Heart Journal

JF - American Heart Journal

SN - 0002-8703

IS - 5

ER -