Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks: An experimental study

M. Akbari, A. Tamayol, M. Bahrami

Research output: Contribution to conferencePaper

5 Citations (Scopus)

Abstract

This study presents an experimental stack-level thermal and hydrodynamic assessment of a model air-cooled PEM fuel cell. To mimic the heat generation inside the MEA, rubber heater films are used. Pressure drop along the stack channels and temperature distribution on the bipolar plate surface are measured for the channel Reynolds number range of 200-500 and the stack input power range of 100-250 W. Tests are performed with and without gas diffusion layers (GDL) to investigate the effect of GDL and its surface characteristics on the pressure drop and heat transfer. Our results indicate that, with the existing length of bipolar plates, a major part of plate minichannel is filled with the developing region. This leads to a higher heat transfer rates, thus more uniform stack temperature can be obtained with the penalty of higher fan power. The minimum measured temperature difference is about 10°C and the values become more pronounced when the Reynolds number decreases. The existence of the GDL is observed to have negligible effect on the pressure drop.

Original languageEnglish (US)
Pages1-11
Number of pages11
DOIs
StatePublished - Jan 1 2012
Event19th World Hydrogen Energy Conference, WHEC 2012 - Toronto, ON, Canada
Duration: Jun 3 2012Jun 7 2012

Other

Other19th World Hydrogen Energy Conference, WHEC 2012
CountryCanada
CityToronto, ON
Period6/3/126/7/12

Fingerprint

Diffusion in gases
Proton exchange membrane fuel cells (PEMFC)
Pressure drop
Heat transfer
Reynolds number
Air
Heat generation
Fans
Fuel cells
Rubber
Temperature distribution
Hydrodynamics
Temperature
Hot Temperature

Keywords

  • Air-cooled
  • Convective heat transfer
  • Gas diffusion layer
  • PEM fuel cells
  • Thermal management

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment

Cite this

Akbari, M., Tamayol, A., & Bahrami, M. (2012). Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks: An experimental study. 1-11. Paper presented at 19th World Hydrogen Energy Conference, WHEC 2012, Toronto, ON, Canada. https://doi.org/10.1016/j.egypro.2012.09.002

Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks : An experimental study. / Akbari, M.; Tamayol, A.; Bahrami, M.

2012. 1-11 Paper presented at 19th World Hydrogen Energy Conference, WHEC 2012, Toronto, ON, Canada.

Research output: Contribution to conferencePaper

Akbari, M, Tamayol, A & Bahrami, M 2012, 'Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks: An experimental study' Paper presented at 19th World Hydrogen Energy Conference, WHEC 2012, Toronto, ON, Canada, 6/3/12 - 6/7/12, pp. 1-11. https://doi.org/10.1016/j.egypro.2012.09.002
Akbari M, Tamayol A, Bahrami M. Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks: An experimental study. 2012. Paper presented at 19th World Hydrogen Energy Conference, WHEC 2012, Toronto, ON, Canada. https://doi.org/10.1016/j.egypro.2012.09.002
Akbari, M. ; Tamayol, A. ; Bahrami, M. / Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks : An experimental study. Paper presented at 19th World Hydrogen Energy Conference, WHEC 2012, Toronto, ON, Canada.11 p.
@conference{6c2f943aa7384d16964a3c2bb0879f8b,
title = "Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks: An experimental study",
abstract = "This study presents an experimental stack-level thermal and hydrodynamic assessment of a model air-cooled PEM fuel cell. To mimic the heat generation inside the MEA, rubber heater films are used. Pressure drop along the stack channels and temperature distribution on the bipolar plate surface are measured for the channel Reynolds number range of 200-500 and the stack input power range of 100-250 W. Tests are performed with and without gas diffusion layers (GDL) to investigate the effect of GDL and its surface characteristics on the pressure drop and heat transfer. Our results indicate that, with the existing length of bipolar plates, a major part of plate minichannel is filled with the developing region. This leads to a higher heat transfer rates, thus more uniform stack temperature can be obtained with the penalty of higher fan power. The minimum measured temperature difference is about 10°C and the values become more pronounced when the Reynolds number decreases. The existence of the GDL is observed to have negligible effect on the pressure drop.",
keywords = "Air-cooled, Convective heat transfer, Gas diffusion layer, PEM fuel cells, Thermal management",
author = "M. Akbari and A. Tamayol and M. Bahrami",
year = "2012",
month = "1",
day = "1",
doi = "10.1016/j.egypro.2012.09.002",
language = "English (US)",
pages = "1--11",
note = "19th World Hydrogen Energy Conference, WHEC 2012 ; Conference date: 03-06-2012 Through 07-06-2012",

}

TY - CONF

T1 - Thermal assessment of convective heat transfer in air- Cooled PEMFC stacks

T2 - An experimental study

AU - Akbari, M.

AU - Tamayol, A.

AU - Bahrami, M.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - This study presents an experimental stack-level thermal and hydrodynamic assessment of a model air-cooled PEM fuel cell. To mimic the heat generation inside the MEA, rubber heater films are used. Pressure drop along the stack channels and temperature distribution on the bipolar plate surface are measured for the channel Reynolds number range of 200-500 and the stack input power range of 100-250 W. Tests are performed with and without gas diffusion layers (GDL) to investigate the effect of GDL and its surface characteristics on the pressure drop and heat transfer. Our results indicate that, with the existing length of bipolar plates, a major part of plate minichannel is filled with the developing region. This leads to a higher heat transfer rates, thus more uniform stack temperature can be obtained with the penalty of higher fan power. The minimum measured temperature difference is about 10°C and the values become more pronounced when the Reynolds number decreases. The existence of the GDL is observed to have negligible effect on the pressure drop.

AB - This study presents an experimental stack-level thermal and hydrodynamic assessment of a model air-cooled PEM fuel cell. To mimic the heat generation inside the MEA, rubber heater films are used. Pressure drop along the stack channels and temperature distribution on the bipolar plate surface are measured for the channel Reynolds number range of 200-500 and the stack input power range of 100-250 W. Tests are performed with and without gas diffusion layers (GDL) to investigate the effect of GDL and its surface characteristics on the pressure drop and heat transfer. Our results indicate that, with the existing length of bipolar plates, a major part of plate minichannel is filled with the developing region. This leads to a higher heat transfer rates, thus more uniform stack temperature can be obtained with the penalty of higher fan power. The minimum measured temperature difference is about 10°C and the values become more pronounced when the Reynolds number decreases. The existence of the GDL is observed to have negligible effect on the pressure drop.

KW - Air-cooled

KW - Convective heat transfer

KW - Gas diffusion layer

KW - PEM fuel cells

KW - Thermal management

UR - http://www.scopus.com/inward/record.url?scp=84874677206&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874677206&partnerID=8YFLogxK

U2 - 10.1016/j.egypro.2012.09.002

DO - 10.1016/j.egypro.2012.09.002

M3 - Paper

AN - SCOPUS:84874677206

SP - 1

EP - 11

ER -