The reliability of auditory thresholds in the 8- to 20-kHz range using a prototype audiometer

P. G. Stelmachowicz, K. A. Beauchaine, A. Kalberer, T. Langer, Walt Jesteadt

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

This study was designed to evaluate both intra- and intertester reliability of auditory thresholds in the 8- to 20-kHz range using a recently developed high-frequency audiometer [Stevens et al, J. Acoust. Soc. Am. 81, 470-484 (1987)]. With this device, signals from a high-frequency transducer are introduced into the ear canal via a plastic tube. A calibration function is calculated for each ear and used to estimate the sound-pressure level (SPL) at the tympanic membrane. Twenty normal-hearing listeners were tested four times, twice by each of two examiners. In the higher frequencies, accurate calibration functions could not be obtained for many subjects; in these cases, values extrapolated from lower frequencies were used to estimate SPL. Findings reveal that the standard error of measurement for both intra- and intertester measures increases as a function of frequency. Intertester variability was only slightly higher than intratester variability. In most cases, variability of threshold estimates in dB SPL was higher than that observed for the uncorrected attenuator settings. Exclusion of extrapolated values improved reliability substantially. PACS numbers: 43.66.Sr, 43.66.Yw.

Original languageEnglish (US)
Pages (from-to)1528-1535
Number of pages8
JournalJournal of the Acoustical Society of America
Volume83
Issue number4
DOIs
StatePublished - Apr 1988

Fingerprint

sound pressure
prototypes
ear
thresholds
estimates
canals
attenuators
hearing
exclusion
transducers
plastics
tubes
membranes
low frequencies
Prototype
Hearing
Sound
Ear
Calibration

ASJC Scopus subject areas

  • Arts and Humanities (miscellaneous)
  • Acoustics and Ultrasonics

Cite this

The reliability of auditory thresholds in the 8- to 20-kHz range using a prototype audiometer. / Stelmachowicz, P. G.; Beauchaine, K. A.; Kalberer, A.; Langer, T.; Jesteadt, Walt.

In: Journal of the Acoustical Society of America, Vol. 83, No. 4, 04.1988, p. 1528-1535.

Research output: Contribution to journalArticle

Stelmachowicz, P. G. ; Beauchaine, K. A. ; Kalberer, A. ; Langer, T. ; Jesteadt, Walt. / The reliability of auditory thresholds in the 8- to 20-kHz range using a prototype audiometer. In: Journal of the Acoustical Society of America. 1988 ; Vol. 83, No. 4. pp. 1528-1535.
@article{b73221aae9cf4b1fa47919589baf965e,
title = "The reliability of auditory thresholds in the 8- to 20-kHz range using a prototype audiometer",
abstract = "This study was designed to evaluate both intra- and intertester reliability of auditory thresholds in the 8- to 20-kHz range using a recently developed high-frequency audiometer [Stevens et al, J. Acoust. Soc. Am. 81, 470-484 (1987)]. With this device, signals from a high-frequency transducer are introduced into the ear canal via a plastic tube. A calibration function is calculated for each ear and used to estimate the sound-pressure level (SPL) at the tympanic membrane. Twenty normal-hearing listeners were tested four times, twice by each of two examiners. In the higher frequencies, accurate calibration functions could not be obtained for many subjects; in these cases, values extrapolated from lower frequencies were used to estimate SPL. Findings reveal that the standard error of measurement for both intra- and intertester measures increases as a function of frequency. Intertester variability was only slightly higher than intratester variability. In most cases, variability of threshold estimates in dB SPL was higher than that observed for the uncorrected attenuator settings. Exclusion of extrapolated values improved reliability substantially. PACS numbers: 43.66.Sr, 43.66.Yw.",
author = "Stelmachowicz, {P. G.} and Beauchaine, {K. A.} and A. Kalberer and T. Langer and Walt Jesteadt",
year = "1988",
month = "4",
doi = "10.1121/1.395909",
language = "English (US)",
volume = "83",
pages = "1528--1535",
journal = "Journal of the Acoustical Society of America",
issn = "0001-4966",
publisher = "Acoustical Society of America",
number = "4",

}

TY - JOUR

T1 - The reliability of auditory thresholds in the 8- to 20-kHz range using a prototype audiometer

AU - Stelmachowicz, P. G.

AU - Beauchaine, K. A.

AU - Kalberer, A.

AU - Langer, T.

AU - Jesteadt, Walt

PY - 1988/4

Y1 - 1988/4

N2 - This study was designed to evaluate both intra- and intertester reliability of auditory thresholds in the 8- to 20-kHz range using a recently developed high-frequency audiometer [Stevens et al, J. Acoust. Soc. Am. 81, 470-484 (1987)]. With this device, signals from a high-frequency transducer are introduced into the ear canal via a plastic tube. A calibration function is calculated for each ear and used to estimate the sound-pressure level (SPL) at the tympanic membrane. Twenty normal-hearing listeners were tested four times, twice by each of two examiners. In the higher frequencies, accurate calibration functions could not be obtained for many subjects; in these cases, values extrapolated from lower frequencies were used to estimate SPL. Findings reveal that the standard error of measurement for both intra- and intertester measures increases as a function of frequency. Intertester variability was only slightly higher than intratester variability. In most cases, variability of threshold estimates in dB SPL was higher than that observed for the uncorrected attenuator settings. Exclusion of extrapolated values improved reliability substantially. PACS numbers: 43.66.Sr, 43.66.Yw.

AB - This study was designed to evaluate both intra- and intertester reliability of auditory thresholds in the 8- to 20-kHz range using a recently developed high-frequency audiometer [Stevens et al, J. Acoust. Soc. Am. 81, 470-484 (1987)]. With this device, signals from a high-frequency transducer are introduced into the ear canal via a plastic tube. A calibration function is calculated for each ear and used to estimate the sound-pressure level (SPL) at the tympanic membrane. Twenty normal-hearing listeners were tested four times, twice by each of two examiners. In the higher frequencies, accurate calibration functions could not be obtained for many subjects; in these cases, values extrapolated from lower frequencies were used to estimate SPL. Findings reveal that the standard error of measurement for both intra- and intertester measures increases as a function of frequency. Intertester variability was only slightly higher than intratester variability. In most cases, variability of threshold estimates in dB SPL was higher than that observed for the uncorrected attenuator settings. Exclusion of extrapolated values improved reliability substantially. PACS numbers: 43.66.Sr, 43.66.Yw.

UR - http://www.scopus.com/inward/record.url?scp=0023929682&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023929682&partnerID=8YFLogxK

U2 - 10.1121/1.395909

DO - 10.1121/1.395909

M3 - Article

C2 - 3372868

AN - SCOPUS:0023929682

VL - 83

SP - 1528

EP - 1535

JO - Journal of the Acoustical Society of America

JF - Journal of the Acoustical Society of America

SN - 0001-4966

IS - 4

ER -