The nonstress test: The false negative test

Jeffrey P. Phelan, A. D. Cromartie, C. V. Smith

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

The nonstress test (NST) has been shown to be a reliable technique for the evaluation of fetal status. As a rule, a reactive NST, as opposed to a nonreactive NST, has been associated with a good pregnancy outcome. Nonetheless, fetal death has followed a reactive test. Because of the uncommon occurrence of a false negative NST, a retrospective investigation of the 2,226 patients who had undergone 4,500 NSTs was undertaken. Of these high-risk pregnancies, 1,564 women were delivered within 7 days of a reactive NST and there were four fetal deaths (0.026%). The presumed etiology for the four deaths was cord accident in three cases and abruptio placentae in one case. As with the false negative contraction stress test, the false negative NST appears to be associated with cord accidents, congenital anomalies, and abruptio placentae. Even though a reactive NST is associated with a low incidence of fetal death, close attention to the presence of fetal heart rate decelerations on the NST may be helpful in identifying those patients at risk for a cord accident and, theoretically, in reducing the incidence of fetal death. Even then, certain unavoidable situations can occur soon after a reactive NST, and, at present, no test of fetal well-being offers complete reassurance.

Original languageEnglish (US)
Pages (from-to)293-296
Number of pages4
JournalAmerican Journal of Obstetrics and Gynecology
Volume142
Issue number3
DOIs
StatePublished - Feb 1 1982

Fingerprint

Fetal Death
Accidents
Abruptio Placentae
High-Risk Pregnancy
Fetal Heart Rate
Deceleration
Incidence
Pregnancy Outcome
Exercise Test

ASJC Scopus subject areas

  • Obstetrics and Gynecology

Cite this

The nonstress test : The false negative test. / Phelan, Jeffrey P.; Cromartie, A. D.; Smith, C. V.

In: American Journal of Obstetrics and Gynecology, Vol. 142, No. 3, 01.02.1982, p. 293-296.

Research output: Contribution to journalArticle

Phelan, Jeffrey P. ; Cromartie, A. D. ; Smith, C. V. / The nonstress test : The false negative test. In: American Journal of Obstetrics and Gynecology. 1982 ; Vol. 142, No. 3. pp. 293-296.
@article{3f1650a5bef7463b9abf3412c58fbd49,
title = "The nonstress test: The false negative test",
abstract = "The nonstress test (NST) has been shown to be a reliable technique for the evaluation of fetal status. As a rule, a reactive NST, as opposed to a nonreactive NST, has been associated with a good pregnancy outcome. Nonetheless, fetal death has followed a reactive test. Because of the uncommon occurrence of a false negative NST, a retrospective investigation of the 2,226 patients who had undergone 4,500 NSTs was undertaken. Of these high-risk pregnancies, 1,564 women were delivered within 7 days of a reactive NST and there were four fetal deaths (0.026{\%}). The presumed etiology for the four deaths was cord accident in three cases and abruptio placentae in one case. As with the false negative contraction stress test, the false negative NST appears to be associated with cord accidents, congenital anomalies, and abruptio placentae. Even though a reactive NST is associated with a low incidence of fetal death, close attention to the presence of fetal heart rate decelerations on the NST may be helpful in identifying those patients at risk for a cord accident and, theoretically, in reducing the incidence of fetal death. Even then, certain unavoidable situations can occur soon after a reactive NST, and, at present, no test of fetal well-being offers complete reassurance.",
author = "Phelan, {Jeffrey P.} and Cromartie, {A. D.} and Smith, {C. V.}",
year = "1982",
month = "2",
day = "1",
doi = "10.1016/0002-9378(82)90733-5",
language = "English (US)",
volume = "142",
pages = "293--296",
journal = "American Journal of Obstetrics and Gynecology",
issn = "0002-9378",
publisher = "Mosby Inc.",
number = "3",

}

TY - JOUR

T1 - The nonstress test

T2 - The false negative test

AU - Phelan, Jeffrey P.

AU - Cromartie, A. D.

AU - Smith, C. V.

PY - 1982/2/1

Y1 - 1982/2/1

N2 - The nonstress test (NST) has been shown to be a reliable technique for the evaluation of fetal status. As a rule, a reactive NST, as opposed to a nonreactive NST, has been associated with a good pregnancy outcome. Nonetheless, fetal death has followed a reactive test. Because of the uncommon occurrence of a false negative NST, a retrospective investigation of the 2,226 patients who had undergone 4,500 NSTs was undertaken. Of these high-risk pregnancies, 1,564 women were delivered within 7 days of a reactive NST and there were four fetal deaths (0.026%). The presumed etiology for the four deaths was cord accident in three cases and abruptio placentae in one case. As with the false negative contraction stress test, the false negative NST appears to be associated with cord accidents, congenital anomalies, and abruptio placentae. Even though a reactive NST is associated with a low incidence of fetal death, close attention to the presence of fetal heart rate decelerations on the NST may be helpful in identifying those patients at risk for a cord accident and, theoretically, in reducing the incidence of fetal death. Even then, certain unavoidable situations can occur soon after a reactive NST, and, at present, no test of fetal well-being offers complete reassurance.

AB - The nonstress test (NST) has been shown to be a reliable technique for the evaluation of fetal status. As a rule, a reactive NST, as opposed to a nonreactive NST, has been associated with a good pregnancy outcome. Nonetheless, fetal death has followed a reactive test. Because of the uncommon occurrence of a false negative NST, a retrospective investigation of the 2,226 patients who had undergone 4,500 NSTs was undertaken. Of these high-risk pregnancies, 1,564 women were delivered within 7 days of a reactive NST and there were four fetal deaths (0.026%). The presumed etiology for the four deaths was cord accident in three cases and abruptio placentae in one case. As with the false negative contraction stress test, the false negative NST appears to be associated with cord accidents, congenital anomalies, and abruptio placentae. Even though a reactive NST is associated with a low incidence of fetal death, close attention to the presence of fetal heart rate decelerations on the NST may be helpful in identifying those patients at risk for a cord accident and, theoretically, in reducing the incidence of fetal death. Even then, certain unavoidable situations can occur soon after a reactive NST, and, at present, no test of fetal well-being offers complete reassurance.

UR - http://www.scopus.com/inward/record.url?scp=0020047458&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0020047458&partnerID=8YFLogxK

U2 - 10.1016/0002-9378(82)90733-5

DO - 10.1016/0002-9378(82)90733-5

M3 - Article

C2 - 7065018

AN - SCOPUS:0020047458

VL - 142

SP - 293

EP - 296

JO - American Journal of Obstetrics and Gynecology

JF - American Journal of Obstetrics and Gynecology

SN - 0002-9378

IS - 3

ER -