The influence of electrode orientation on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis

Clayton Camic, Terry Housh, Jorge M Zuniga, Russell Hendrix, Michelle Mielke, Glen Johnson, Richard Schmidt

Research output: Contribution to journalArticle

Abstract

Camic CL, Housh TJ, Zuniga JM, Hendrix CR, Mielke M, Johnson GO, Schmidt RJ. The Influence of Electrode Orientation on the Electromyographic Amplitude and Mean Power Frequency Versus Isometric Torque Relationships for the Vastus Lateralis. JEPonline 2010;13(1):10-20. The purposes of this study were to compare parallel versus perpendicular electrode orientations during isometric muscle actions for: 1) the torque-related patterns of responses for electromyographic (EMG) amplitude and mean power frequency (MPF); 2) the mean absolute EMG amplitude and MPF values; and 3) the mean normalized EMG amplitude and MPF values. Eleven adults (mean ± SD age = 23.9 ± 3.0) performed isometric muscle actions at 10 - 100% MVC on a Cybex II dynamometer. Two bipolar EMG electrode arrangements were placed approximately parallel and perpendicular to the muscle fibers over the vastus lateralis. Twenty-seven percent of the subjects exhibited different torque-related patterns of responses between electrode orientations for EMG amplitude and 55% exhibited different patterns for MPF. The mean absolute EMG amplitude and MPF values were greater for the parallel than the perpendicular electrode orientation for 10 and 9 of the torque levels, respectively. For the normalized EMG amplitude and MPF values, however, the parallel electrode orientation was greater than the perpendicular for only 2 and 1 torque level, respectively. These findings indicated that normalization reduced, but did not eliminate, the influence of electrode orientation and emphasized the importance of standardizing electrode orientation to compare EMG values.

Original languageEnglish (US)
Pages (from-to)10-20
Number of pages11
JournalJournal of Exercise Physiology Online
Volume13
Issue number1
StatePublished - Feb 1 2010

Fingerprint

Quadriceps Muscle
Torque
Electrodes
Muscles

Keywords

  • Normalization
  • Parallel
  • Perpendicular

ASJC Scopus subject areas

  • Physiology (medical)

Cite this

The influence of electrode orientation on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis. / Camic, Clayton; Housh, Terry; Zuniga, Jorge M; Hendrix, Russell; Mielke, Michelle; Johnson, Glen; Schmidt, Richard.

In: Journal of Exercise Physiology Online, Vol. 13, No. 1, 01.02.2010, p. 10-20.

Research output: Contribution to journalArticle

Camic, Clayton ; Housh, Terry ; Zuniga, Jorge M ; Hendrix, Russell ; Mielke, Michelle ; Johnson, Glen ; Schmidt, Richard. / The influence of electrode orientation on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis. In: Journal of Exercise Physiology Online. 2010 ; Vol. 13, No. 1. pp. 10-20.
@article{e69a24338bb0414d8ac98703bcd8aa16,
title = "The influence of electrode orientation on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis",
abstract = "Camic CL, Housh TJ, Zuniga JM, Hendrix CR, Mielke M, Johnson GO, Schmidt RJ. The Influence of Electrode Orientation on the Electromyographic Amplitude and Mean Power Frequency Versus Isometric Torque Relationships for the Vastus Lateralis. JEPonline 2010;13(1):10-20. The purposes of this study were to compare parallel versus perpendicular electrode orientations during isometric muscle actions for: 1) the torque-related patterns of responses for electromyographic (EMG) amplitude and mean power frequency (MPF); 2) the mean absolute EMG amplitude and MPF values; and 3) the mean normalized EMG amplitude and MPF values. Eleven adults (mean ± SD age = 23.9 ± 3.0) performed isometric muscle actions at 10 - 100{\%} MVC on a Cybex II dynamometer. Two bipolar EMG electrode arrangements were placed approximately parallel and perpendicular to the muscle fibers over the vastus lateralis. Twenty-seven percent of the subjects exhibited different torque-related patterns of responses between electrode orientations for EMG amplitude and 55{\%} exhibited different patterns for MPF. The mean absolute EMG amplitude and MPF values were greater for the parallel than the perpendicular electrode orientation for 10 and 9 of the torque levels, respectively. For the normalized EMG amplitude and MPF values, however, the parallel electrode orientation was greater than the perpendicular for only 2 and 1 torque level, respectively. These findings indicated that normalization reduced, but did not eliminate, the influence of electrode orientation and emphasized the importance of standardizing electrode orientation to compare EMG values.",
keywords = "Normalization, Parallel, Perpendicular",
author = "Clayton Camic and Terry Housh and Zuniga, {Jorge M} and Russell Hendrix and Michelle Mielke and Glen Johnson and Richard Schmidt",
year = "2010",
month = "2",
day = "1",
language = "English (US)",
volume = "13",
pages = "10--20",
journal = "Journal of Exercise Physiology Online",
issn = "1097-9751",
publisher = "American Society of Exercise Physiologists",
number = "1",

}

TY - JOUR

T1 - The influence of electrode orientation on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus lateralis

AU - Camic, Clayton

AU - Housh, Terry

AU - Zuniga, Jorge M

AU - Hendrix, Russell

AU - Mielke, Michelle

AU - Johnson, Glen

AU - Schmidt, Richard

PY - 2010/2/1

Y1 - 2010/2/1

N2 - Camic CL, Housh TJ, Zuniga JM, Hendrix CR, Mielke M, Johnson GO, Schmidt RJ. The Influence of Electrode Orientation on the Electromyographic Amplitude and Mean Power Frequency Versus Isometric Torque Relationships for the Vastus Lateralis. JEPonline 2010;13(1):10-20. The purposes of this study were to compare parallel versus perpendicular electrode orientations during isometric muscle actions for: 1) the torque-related patterns of responses for electromyographic (EMG) amplitude and mean power frequency (MPF); 2) the mean absolute EMG amplitude and MPF values; and 3) the mean normalized EMG amplitude and MPF values. Eleven adults (mean ± SD age = 23.9 ± 3.0) performed isometric muscle actions at 10 - 100% MVC on a Cybex II dynamometer. Two bipolar EMG electrode arrangements were placed approximately parallel and perpendicular to the muscle fibers over the vastus lateralis. Twenty-seven percent of the subjects exhibited different torque-related patterns of responses between electrode orientations for EMG amplitude and 55% exhibited different patterns for MPF. The mean absolute EMG amplitude and MPF values were greater for the parallel than the perpendicular electrode orientation for 10 and 9 of the torque levels, respectively. For the normalized EMG amplitude and MPF values, however, the parallel electrode orientation was greater than the perpendicular for only 2 and 1 torque level, respectively. These findings indicated that normalization reduced, but did not eliminate, the influence of electrode orientation and emphasized the importance of standardizing electrode orientation to compare EMG values.

AB - Camic CL, Housh TJ, Zuniga JM, Hendrix CR, Mielke M, Johnson GO, Schmidt RJ. The Influence of Electrode Orientation on the Electromyographic Amplitude and Mean Power Frequency Versus Isometric Torque Relationships for the Vastus Lateralis. JEPonline 2010;13(1):10-20. The purposes of this study were to compare parallel versus perpendicular electrode orientations during isometric muscle actions for: 1) the torque-related patterns of responses for electromyographic (EMG) amplitude and mean power frequency (MPF); 2) the mean absolute EMG amplitude and MPF values; and 3) the mean normalized EMG amplitude and MPF values. Eleven adults (mean ± SD age = 23.9 ± 3.0) performed isometric muscle actions at 10 - 100% MVC on a Cybex II dynamometer. Two bipolar EMG electrode arrangements were placed approximately parallel and perpendicular to the muscle fibers over the vastus lateralis. Twenty-seven percent of the subjects exhibited different torque-related patterns of responses between electrode orientations for EMG amplitude and 55% exhibited different patterns for MPF. The mean absolute EMG amplitude and MPF values were greater for the parallel than the perpendicular electrode orientation for 10 and 9 of the torque levels, respectively. For the normalized EMG amplitude and MPF values, however, the parallel electrode orientation was greater than the perpendicular for only 2 and 1 torque level, respectively. These findings indicated that normalization reduced, but did not eliminate, the influence of electrode orientation and emphasized the importance of standardizing electrode orientation to compare EMG values.

KW - Normalization

KW - Parallel

KW - Perpendicular

UR - http://www.scopus.com/inward/record.url?scp=77955840327&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77955840327&partnerID=8YFLogxK

M3 - Article

VL - 13

SP - 10

EP - 20

JO - Journal of Exercise Physiology Online

JF - Journal of Exercise Physiology Online

SN - 1097-9751

IS - 1