The effect of tibial tuberosity realignment procedures on the patellofemoral pressure distribution

Archana Saranathan, Marcus S Kirkpatrick, Saandeep Mani, Laura G. Smith, Andrew J. Cosgarea, Juay Seng Tan, John J. Elias

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

Purpose: The study was performed to characterize the influence of tibial tuberosity realignment on the pressure applied to cartilage on the patella in the intact condition and with lesions on the lateral and medial facets. Methods: Ten knees were loaded in vitro through the quadriceps (586 N) and hamstrings (200 N) at 40°, 60°, and 80° of flexion while measuring patellofemoral contact pressures with a pressure sensor. The tibial tuberosity was positioned 5 mm lateral of the normal position to represent lateral malalignment, 5 mm medial of the normal position to represent tuberosity medialization, and 10 mm anterior of the medial position to represent tuberosity anteromedialization. The knees were tested with intact cartilage, with a 12-mm-diameter lesion created within the lateral patellar cartilage, and with the lateral lesion repaired with silicone combined with a medial lesion. A repeated measures ANOVA and post hoc tests were used to identify significant (P < 0. 05) differences in the maximum lateral and medial pressure between the tuberosity positions. Results: Tuberosity medialization and anteromedialization significantly decreased the maximum lateral pressure by approximately 15% at 60° and 80° for intact cartilage and cartilage with a lateral lesion. Tuberosity medialization significantly increased the maximum medial pressure for intact cartilage at 80°, but the maximum medial pressure did not exceed the maximum lateral pressure for any testing condition. Conclusions: The results indicate that medializing the tibial tuberosity by 10 mm reduces the pressure applied to lateral patellar cartilage for intact cartilage and cartilage with lateral lesions, but does not overload medial cartilage.

Original languageEnglish (US)
Pages (from-to)2054-2061
Number of pages8
JournalKnee Surgery, Sports Traumatology, Arthroscopy
Volume20
Issue number10
DOIs
StatePublished - Jan 1 2012

Fingerprint

Cartilage
Pressure
Knee
Patella
Silicones
Analysis of Variance

Keywords

  • Kinematics
  • Lesions
  • Malalignment
  • Patellofemoral
  • Pressure
  • Tuberosity realignment

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Cite this

Saranathan, A., Kirkpatrick, M. S., Mani, S., Smith, L. G., Cosgarea, A. J., Tan, J. S., & Elias, J. J. (2012). The effect of tibial tuberosity realignment procedures on the patellofemoral pressure distribution. Knee Surgery, Sports Traumatology, Arthroscopy, 20(10), 2054-2061. https://doi.org/10.1007/s00167-011-1802-8

The effect of tibial tuberosity realignment procedures on the patellofemoral pressure distribution. / Saranathan, Archana; Kirkpatrick, Marcus S; Mani, Saandeep; Smith, Laura G.; Cosgarea, Andrew J.; Tan, Juay Seng; Elias, John J.

In: Knee Surgery, Sports Traumatology, Arthroscopy, Vol. 20, No. 10, 01.01.2012, p. 2054-2061.

Research output: Contribution to journalArticle

Saranathan, A, Kirkpatrick, MS, Mani, S, Smith, LG, Cosgarea, AJ, Tan, JS & Elias, JJ 2012, 'The effect of tibial tuberosity realignment procedures on the patellofemoral pressure distribution', Knee Surgery, Sports Traumatology, Arthroscopy, vol. 20, no. 10, pp. 2054-2061. https://doi.org/10.1007/s00167-011-1802-8
Saranathan, Archana ; Kirkpatrick, Marcus S ; Mani, Saandeep ; Smith, Laura G. ; Cosgarea, Andrew J. ; Tan, Juay Seng ; Elias, John J. / The effect of tibial tuberosity realignment procedures on the patellofemoral pressure distribution. In: Knee Surgery, Sports Traumatology, Arthroscopy. 2012 ; Vol. 20, No. 10. pp. 2054-2061.
@article{ce6660eab1dc4cdeb1e00401d98989eb,
title = "The effect of tibial tuberosity realignment procedures on the patellofemoral pressure distribution",
abstract = "Purpose: The study was performed to characterize the influence of tibial tuberosity realignment on the pressure applied to cartilage on the patella in the intact condition and with lesions on the lateral and medial facets. Methods: Ten knees were loaded in vitro through the quadriceps (586 N) and hamstrings (200 N) at 40°, 60°, and 80° of flexion while measuring patellofemoral contact pressures with a pressure sensor. The tibial tuberosity was positioned 5 mm lateral of the normal position to represent lateral malalignment, 5 mm medial of the normal position to represent tuberosity medialization, and 10 mm anterior of the medial position to represent tuberosity anteromedialization. The knees were tested with intact cartilage, with a 12-mm-diameter lesion created within the lateral patellar cartilage, and with the lateral lesion repaired with silicone combined with a medial lesion. A repeated measures ANOVA and post hoc tests were used to identify significant (P < 0. 05) differences in the maximum lateral and medial pressure between the tuberosity positions. Results: Tuberosity medialization and anteromedialization significantly decreased the maximum lateral pressure by approximately 15{\%} at 60° and 80° for intact cartilage and cartilage with a lateral lesion. Tuberosity medialization significantly increased the maximum medial pressure for intact cartilage at 80°, but the maximum medial pressure did not exceed the maximum lateral pressure for any testing condition. Conclusions: The results indicate that medializing the tibial tuberosity by 10 mm reduces the pressure applied to lateral patellar cartilage for intact cartilage and cartilage with lateral lesions, but does not overload medial cartilage.",
keywords = "Kinematics, Lesions, Malalignment, Patellofemoral, Pressure, Tuberosity realignment",
author = "Archana Saranathan and Kirkpatrick, {Marcus S} and Saandeep Mani and Smith, {Laura G.} and Cosgarea, {Andrew J.} and Tan, {Juay Seng} and Elias, {John J.}",
year = "2012",
month = "1",
day = "1",
doi = "10.1007/s00167-011-1802-8",
language = "English (US)",
volume = "20",
pages = "2054--2061",
journal = "Knee Surgery, Sports Traumatology, Arthroscopy",
issn = "0942-2056",
publisher = "Springer Verlag",
number = "10",

}

TY - JOUR

T1 - The effect of tibial tuberosity realignment procedures on the patellofemoral pressure distribution

AU - Saranathan, Archana

AU - Kirkpatrick, Marcus S

AU - Mani, Saandeep

AU - Smith, Laura G.

AU - Cosgarea, Andrew J.

AU - Tan, Juay Seng

AU - Elias, John J.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - Purpose: The study was performed to characterize the influence of tibial tuberosity realignment on the pressure applied to cartilage on the patella in the intact condition and with lesions on the lateral and medial facets. Methods: Ten knees were loaded in vitro through the quadriceps (586 N) and hamstrings (200 N) at 40°, 60°, and 80° of flexion while measuring patellofemoral contact pressures with a pressure sensor. The tibial tuberosity was positioned 5 mm lateral of the normal position to represent lateral malalignment, 5 mm medial of the normal position to represent tuberosity medialization, and 10 mm anterior of the medial position to represent tuberosity anteromedialization. The knees were tested with intact cartilage, with a 12-mm-diameter lesion created within the lateral patellar cartilage, and with the lateral lesion repaired with silicone combined with a medial lesion. A repeated measures ANOVA and post hoc tests were used to identify significant (P < 0. 05) differences in the maximum lateral and medial pressure between the tuberosity positions. Results: Tuberosity medialization and anteromedialization significantly decreased the maximum lateral pressure by approximately 15% at 60° and 80° for intact cartilage and cartilage with a lateral lesion. Tuberosity medialization significantly increased the maximum medial pressure for intact cartilage at 80°, but the maximum medial pressure did not exceed the maximum lateral pressure for any testing condition. Conclusions: The results indicate that medializing the tibial tuberosity by 10 mm reduces the pressure applied to lateral patellar cartilage for intact cartilage and cartilage with lateral lesions, but does not overload medial cartilage.

AB - Purpose: The study was performed to characterize the influence of tibial tuberosity realignment on the pressure applied to cartilage on the patella in the intact condition and with lesions on the lateral and medial facets. Methods: Ten knees were loaded in vitro through the quadriceps (586 N) and hamstrings (200 N) at 40°, 60°, and 80° of flexion while measuring patellofemoral contact pressures with a pressure sensor. The tibial tuberosity was positioned 5 mm lateral of the normal position to represent lateral malalignment, 5 mm medial of the normal position to represent tuberosity medialization, and 10 mm anterior of the medial position to represent tuberosity anteromedialization. The knees were tested with intact cartilage, with a 12-mm-diameter lesion created within the lateral patellar cartilage, and with the lateral lesion repaired with silicone combined with a medial lesion. A repeated measures ANOVA and post hoc tests were used to identify significant (P < 0. 05) differences in the maximum lateral and medial pressure between the tuberosity positions. Results: Tuberosity medialization and anteromedialization significantly decreased the maximum lateral pressure by approximately 15% at 60° and 80° for intact cartilage and cartilage with a lateral lesion. Tuberosity medialization significantly increased the maximum medial pressure for intact cartilage at 80°, but the maximum medial pressure did not exceed the maximum lateral pressure for any testing condition. Conclusions: The results indicate that medializing the tibial tuberosity by 10 mm reduces the pressure applied to lateral patellar cartilage for intact cartilage and cartilage with lateral lesions, but does not overload medial cartilage.

KW - Kinematics

KW - Lesions

KW - Malalignment

KW - Patellofemoral

KW - Pressure

KW - Tuberosity realignment

UR - http://www.scopus.com/inward/record.url?scp=84866933229&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84866933229&partnerID=8YFLogxK

U2 - 10.1007/s00167-011-1802-8

DO - 10.1007/s00167-011-1802-8

M3 - Article

VL - 20

SP - 2054

EP - 2061

JO - Knee Surgery, Sports Traumatology, Arthroscopy

JF - Knee Surgery, Sports Traumatology, Arthroscopy

SN - 0942-2056

IS - 10

ER -