Survey of recent advances in analytical applications of immunoaffinity chromatography

Research output: Contribution to journalReview article

131 Citations (Scopus)

Abstract

Methods that use immunoaffinity chromatography (IAC) for sample preparation or detection are becoming increasingly popular as tools in the analysis of biological and nonbiological compounds. This paper presents an overview of immunoaffinity chromatography and examines some recent developments of this technique in analytical applications. The emphasis is placed on HPLC-based IAC methods or those that combine IAC with other instrumental techniques; however, novel approaches that employ low-performance IAC columns for chemical quantitation are also considered. Particular applications that are examined include (1) the use of IAC in the direct detection of analytes, (2) the extraction of samples by IAC prior to on- or off-line detection by other methods, (3) the use of IAC in chromatographic-based immunoassays, and (4) the development of postcolumn reactors based on IAC for the detection of analytes as they elute from other types of chromatographic columns. The advantages and limitations for each approach are considered. In addition, a summary is provided of reports in the literature that have used IAC for these various formats. Copyright (C) 1998 Elsevier Science B.V.

Original languageEnglish (US)
Pages (from-to)3-28
Number of pages26
JournalJournal of Chromatography B: Biomedical Applications
Volume715
Issue number1
DOIs
StatePublished - Sep 11 1998

Fingerprint

Chromatography
Column chromatography

Keywords

  • Antibodies
  • Immunoaffinity chromatography
  • Reviews

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Survey of recent advances in analytical applications of immunoaffinity chromatography. / Hage, David S.

In: Journal of Chromatography B: Biomedical Applications, Vol. 715, No. 1, 11.09.1998, p. 3-28.

Research output: Contribution to journalReview article

@article{4be319ab369342f5b3a7d5c10f13faeb,
title = "Survey of recent advances in analytical applications of immunoaffinity chromatography",
abstract = "Methods that use immunoaffinity chromatography (IAC) for sample preparation or detection are becoming increasingly popular as tools in the analysis of biological and nonbiological compounds. This paper presents an overview of immunoaffinity chromatography and examines some recent developments of this technique in analytical applications. The emphasis is placed on HPLC-based IAC methods or those that combine IAC with other instrumental techniques; however, novel approaches that employ low-performance IAC columns for chemical quantitation are also considered. Particular applications that are examined include (1) the use of IAC in the direct detection of analytes, (2) the extraction of samples by IAC prior to on- or off-line detection by other methods, (3) the use of IAC in chromatographic-based immunoassays, and (4) the development of postcolumn reactors based on IAC for the detection of analytes as they elute from other types of chromatographic columns. The advantages and limitations for each approach are considered. In addition, a summary is provided of reports in the literature that have used IAC for these various formats. Copyright (C) 1998 Elsevier Science B.V.",
keywords = "Antibodies, Immunoaffinity chromatography, Reviews",
author = "Hage, {David S.}",
year = "1998",
month = "9",
day = "11",
doi = "10.1016/S0378-4347(97)00621-X",
language = "English (US)",
volume = "715",
pages = "3--28",
journal = "Journal of Chromatography B: Biomedical Sciences and Applications",
issn = "0378-4347",
publisher = "Elsevier BV",
number = "1",

}

TY - JOUR

T1 - Survey of recent advances in analytical applications of immunoaffinity chromatography

AU - Hage, David S.

PY - 1998/9/11

Y1 - 1998/9/11

N2 - Methods that use immunoaffinity chromatography (IAC) for sample preparation or detection are becoming increasingly popular as tools in the analysis of biological and nonbiological compounds. This paper presents an overview of immunoaffinity chromatography and examines some recent developments of this technique in analytical applications. The emphasis is placed on HPLC-based IAC methods or those that combine IAC with other instrumental techniques; however, novel approaches that employ low-performance IAC columns for chemical quantitation are also considered. Particular applications that are examined include (1) the use of IAC in the direct detection of analytes, (2) the extraction of samples by IAC prior to on- or off-line detection by other methods, (3) the use of IAC in chromatographic-based immunoassays, and (4) the development of postcolumn reactors based on IAC for the detection of analytes as they elute from other types of chromatographic columns. The advantages and limitations for each approach are considered. In addition, a summary is provided of reports in the literature that have used IAC for these various formats. Copyright (C) 1998 Elsevier Science B.V.

AB - Methods that use immunoaffinity chromatography (IAC) for sample preparation or detection are becoming increasingly popular as tools in the analysis of biological and nonbiological compounds. This paper presents an overview of immunoaffinity chromatography and examines some recent developments of this technique in analytical applications. The emphasis is placed on HPLC-based IAC methods or those that combine IAC with other instrumental techniques; however, novel approaches that employ low-performance IAC columns for chemical quantitation are also considered. Particular applications that are examined include (1) the use of IAC in the direct detection of analytes, (2) the extraction of samples by IAC prior to on- or off-line detection by other methods, (3) the use of IAC in chromatographic-based immunoassays, and (4) the development of postcolumn reactors based on IAC for the detection of analytes as they elute from other types of chromatographic columns. The advantages and limitations for each approach are considered. In addition, a summary is provided of reports in the literature that have used IAC for these various formats. Copyright (C) 1998 Elsevier Science B.V.

KW - Antibodies

KW - Immunoaffinity chromatography

KW - Reviews

UR - http://www.scopus.com/inward/record.url?scp=0032508563&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032508563&partnerID=8YFLogxK

U2 - 10.1016/S0378-4347(97)00621-X

DO - 10.1016/S0378-4347(97)00621-X

M3 - Review article

C2 - 9792495

AN - SCOPUS:0032508563

VL - 715

SP - 3

EP - 28

JO - Journal of Chromatography B: Biomedical Sciences and Applications

JF - Journal of Chromatography B: Biomedical Sciences and Applications

SN - 0378-4347

IS - 1

ER -