SU‐FF‐T‐316: Modifications to the “three‐Source Model” for the Calculation of Head Scatter Factors for Small Field Sizes

K. Ayyangar, D. Djajaputra, R. Nehru, P. Sourivong, Y. fu, Charles Arthur Enke

Research output: Contribution to journalArticle

Abstract

Purpose: The three‐source model proposed by Yang et al.1 when applied to Siemens PRIMUS 6 MV beam over‐estimated head scatter by 10–200% for field sizes less than 2 cm × 2 cm and elongated narrow beams. This necessitated the development of a modified approach Method and Materials: The complete theoretical background for the three‐source model can be found in the published literature1 in which the total energy fluence at the point of calculation can be divided into three components. The primary component Cp has been chosen around 90% in the model. A modified approach is proposed to the three‐source model with the primary source component Cp having growth function that grows exponentially with radius of the beam in the Sp plane. The primary source function was integrated in the Sp plane using the formula, [formula omitted]; rs < r3 where Cp2, Cp3 and r3 are fitting coefficients. Results: The measured head scatter factors for smaller field sizes including the rectangular fields where the exchanged collimator jaw positions have been compared with both three‐source model and modified three‐source model for Siemens PRIMUS 6 MV beam. It was observed that the accuracy of the modified model is improved and is within 10% of the measurements for small field sizes. Conclusion: In routine IMRT treatments, about 10–15% of the segmented fields use small or elongated fields. The modified approach to the three‐source model improves the accuracy of the head scatter factors calculation significantly for field sizes below 2 cm × 2cm.

Original languageEnglish (US)
Number of pages1
JournalMedical physics
Volume32
Issue number6
DOIs
StatePublished - Jun 2005

Fingerprint

Hepatocyte Growth Factor
Head
Jaw
Growth

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐FF‐T‐316 : Modifications to the “three‐Source Model” for the Calculation of Head Scatter Factors for Small Field Sizes. / Ayyangar, K.; Djajaputra, D.; Nehru, R.; Sourivong, P.; fu, Y.; Enke, Charles Arthur.

In: Medical physics, Vol. 32, No. 6, 06.2005.

Research output: Contribution to journalArticle

@article{5826ce6ff95c4b78949011fdb42400f8,
title = "SU‐FF‐T‐316: Modifications to the “three‐Source Model” for the Calculation of Head Scatter Factors for Small Field Sizes",
abstract = "Purpose: The three‐source model proposed by Yang et al.1 when applied to Siemens PRIMUS 6 MV beam over‐estimated head scatter by 10–200{\%} for field sizes less than 2 cm × 2 cm and elongated narrow beams. This necessitated the development of a modified approach Method and Materials: The complete theoretical background for the three‐source model can be found in the published literature1 in which the total energy fluence at the point of calculation can be divided into three components. The primary component Cp has been chosen around 90{\%} in the model. A modified approach is proposed to the three‐source model with the primary source component Cp having growth function that grows exponentially with radius of the beam in the Sp plane. The primary source function was integrated in the Sp plane using the formula, [formula omitted]; rs < r3 where Cp2, Cp3 and r3 are fitting coefficients. Results: The measured head scatter factors for smaller field sizes including the rectangular fields where the exchanged collimator jaw positions have been compared with both three‐source model and modified three‐source model for Siemens PRIMUS 6 MV beam. It was observed that the accuracy of the modified model is improved and is within 10{\%} of the measurements for small field sizes. Conclusion: In routine IMRT treatments, about 10–15{\%} of the segmented fields use small or elongated fields. The modified approach to the three‐source model improves the accuracy of the head scatter factors calculation significantly for field sizes below 2 cm × 2cm.",
author = "K. Ayyangar and D. Djajaputra and R. Nehru and P. Sourivong and Y. fu and Enke, {Charles Arthur}",
year = "2005",
month = "6",
doi = "10.1118/1.1998045",
language = "English (US)",
volume = "32",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐FF‐T‐316

T2 - Modifications to the “three‐Source Model” for the Calculation of Head Scatter Factors for Small Field Sizes

AU - Ayyangar, K.

AU - Djajaputra, D.

AU - Nehru, R.

AU - Sourivong, P.

AU - fu, Y.

AU - Enke, Charles Arthur

PY - 2005/6

Y1 - 2005/6

N2 - Purpose: The three‐source model proposed by Yang et al.1 when applied to Siemens PRIMUS 6 MV beam over‐estimated head scatter by 10–200% for field sizes less than 2 cm × 2 cm and elongated narrow beams. This necessitated the development of a modified approach Method and Materials: The complete theoretical background for the three‐source model can be found in the published literature1 in which the total energy fluence at the point of calculation can be divided into three components. The primary component Cp has been chosen around 90% in the model. A modified approach is proposed to the three‐source model with the primary source component Cp having growth function that grows exponentially with radius of the beam in the Sp plane. The primary source function was integrated in the Sp plane using the formula, [formula omitted]; rs < r3 where Cp2, Cp3 and r3 are fitting coefficients. Results: The measured head scatter factors for smaller field sizes including the rectangular fields where the exchanged collimator jaw positions have been compared with both three‐source model and modified three‐source model for Siemens PRIMUS 6 MV beam. It was observed that the accuracy of the modified model is improved and is within 10% of the measurements for small field sizes. Conclusion: In routine IMRT treatments, about 10–15% of the segmented fields use small or elongated fields. The modified approach to the three‐source model improves the accuracy of the head scatter factors calculation significantly for field sizes below 2 cm × 2cm.

AB - Purpose: The three‐source model proposed by Yang et al.1 when applied to Siemens PRIMUS 6 MV beam over‐estimated head scatter by 10–200% for field sizes less than 2 cm × 2 cm and elongated narrow beams. This necessitated the development of a modified approach Method and Materials: The complete theoretical background for the three‐source model can be found in the published literature1 in which the total energy fluence at the point of calculation can be divided into three components. The primary component Cp has been chosen around 90% in the model. A modified approach is proposed to the three‐source model with the primary source component Cp having growth function that grows exponentially with radius of the beam in the Sp plane. The primary source function was integrated in the Sp plane using the formula, [formula omitted]; rs < r3 where Cp2, Cp3 and r3 are fitting coefficients. Results: The measured head scatter factors for smaller field sizes including the rectangular fields where the exchanged collimator jaw positions have been compared with both three‐source model and modified three‐source model for Siemens PRIMUS 6 MV beam. It was observed that the accuracy of the modified model is improved and is within 10% of the measurements for small field sizes. Conclusion: In routine IMRT treatments, about 10–15% of the segmented fields use small or elongated fields. The modified approach to the three‐source model improves the accuracy of the head scatter factors calculation significantly for field sizes below 2 cm × 2cm.

UR - http://www.scopus.com/inward/record.url?scp=85024800464&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024800464&partnerID=8YFLogxK

U2 - 10.1118/1.1998045

DO - 10.1118/1.1998045

M3 - Article

AN - SCOPUS:85024800464

VL - 32

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -