Steep central islands after myopic photorefractive keratectomy

W. Forster, S. Clemens, S. Bruning, T. Magnago, C. Elsner, Ronald R Krueger

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

Purpose: To investigate the formation of steep central islands and their reduction under modified experimental conditions. Setting: University Eye Hospital Munster and Schwind Co., Kleinostheim, Germany. Methods: Corneas of enucleated intact bovine eyes were treated with the Schwind Keratom. All experimental conditions were repeated six times in six different corneas. Eight experimental groups were looked at. Fluence was 180 to 200 mJ/cm2. Ablation mode (phototherapeutic keratectomy [PTK] and standard myopic photorefractive keratectomy [PRK]), internal repetition rate (3 to 30 Hz), and ablation diameter (5 to 8 mm) and depth (4 to 15 diopters [D] in PRK) were varied. Modifications to reduce or avoid steep central islands included blowing nitrogen gas and aerosol over the cornea, cleaning the cornea of fluid, and using an anti-central-island software program. Results: In PTK, an increase in the internal repetition rate resulted in a decrease in the height of the steep central island. In standard PRK, increasing refractive correction up to -8.0 D and increasing the ablation diameter resulted in an increase in steep central island power. The anti-central-island program, blowing aerosol, and cleaning the cornea reduced the formation of steep central islands and blowing nitrogen gas eliminated them. Conclusion: Steep central islands are created by a wide-field ablation process and are probably caused by many factors. Both software and hardware modifications can be used to reduce their formation.

Original languageEnglish (US)
Pages (from-to)899-904
Number of pages6
JournalJournal of cataract and refractive surgery
Volume24
Issue number7
DOIs
StatePublished - Jan 1 1998

Fingerprint

Photorefractive Keratectomy
Islands
Cornea
Aerosols
Nitrogen
Software
Gases
Germany

ASJC Scopus subject areas

  • Surgery
  • Ophthalmology
  • Sensory Systems

Cite this

Steep central islands after myopic photorefractive keratectomy. / Forster, W.; Clemens, S.; Bruning, S.; Magnago, T.; Elsner, C.; Krueger, Ronald R.

In: Journal of cataract and refractive surgery, Vol. 24, No. 7, 01.01.1998, p. 899-904.

Research output: Contribution to journalArticle

Forster, W. ; Clemens, S. ; Bruning, S. ; Magnago, T. ; Elsner, C. ; Krueger, Ronald R. / Steep central islands after myopic photorefractive keratectomy. In: Journal of cataract and refractive surgery. 1998 ; Vol. 24, No. 7. pp. 899-904.
@article{1b2b83a093e847ad93c74907773b8858,
title = "Steep central islands after myopic photorefractive keratectomy",
abstract = "Purpose: To investigate the formation of steep central islands and their reduction under modified experimental conditions. Setting: University Eye Hospital Munster and Schwind Co., Kleinostheim, Germany. Methods: Corneas of enucleated intact bovine eyes were treated with the Schwind Keratom. All experimental conditions were repeated six times in six different corneas. Eight experimental groups were looked at. Fluence was 180 to 200 mJ/cm2. Ablation mode (phototherapeutic keratectomy [PTK] and standard myopic photorefractive keratectomy [PRK]), internal repetition rate (3 to 30 Hz), and ablation diameter (5 to 8 mm) and depth (4 to 15 diopters [D] in PRK) were varied. Modifications to reduce or avoid steep central islands included blowing nitrogen gas and aerosol over the cornea, cleaning the cornea of fluid, and using an anti-central-island software program. Results: In PTK, an increase in the internal repetition rate resulted in a decrease in the height of the steep central island. In standard PRK, increasing refractive correction up to -8.0 D and increasing the ablation diameter resulted in an increase in steep central island power. The anti-central-island program, blowing aerosol, and cleaning the cornea reduced the formation of steep central islands and blowing nitrogen gas eliminated them. Conclusion: Steep central islands are created by a wide-field ablation process and are probably caused by many factors. Both software and hardware modifications can be used to reduce their formation.",
author = "W. Forster and S. Clemens and S. Bruning and T. Magnago and C. Elsner and Krueger, {Ronald R}",
year = "1998",
month = "1",
day = "1",
doi = "10.1016/S0886-3350(98)80040-0",
language = "English (US)",
volume = "24",
pages = "899--904",
journal = "Journal of Cataract and Refractive Surgery",
issn = "0886-3350",
publisher = "Elsevier Inc.",
number = "7",

}

TY - JOUR

T1 - Steep central islands after myopic photorefractive keratectomy

AU - Forster, W.

AU - Clemens, S.

AU - Bruning, S.

AU - Magnago, T.

AU - Elsner, C.

AU - Krueger, Ronald R

PY - 1998/1/1

Y1 - 1998/1/1

N2 - Purpose: To investigate the formation of steep central islands and their reduction under modified experimental conditions. Setting: University Eye Hospital Munster and Schwind Co., Kleinostheim, Germany. Methods: Corneas of enucleated intact bovine eyes were treated with the Schwind Keratom. All experimental conditions were repeated six times in six different corneas. Eight experimental groups were looked at. Fluence was 180 to 200 mJ/cm2. Ablation mode (phototherapeutic keratectomy [PTK] and standard myopic photorefractive keratectomy [PRK]), internal repetition rate (3 to 30 Hz), and ablation diameter (5 to 8 mm) and depth (4 to 15 diopters [D] in PRK) were varied. Modifications to reduce or avoid steep central islands included blowing nitrogen gas and aerosol over the cornea, cleaning the cornea of fluid, and using an anti-central-island software program. Results: In PTK, an increase in the internal repetition rate resulted in a decrease in the height of the steep central island. In standard PRK, increasing refractive correction up to -8.0 D and increasing the ablation diameter resulted in an increase in steep central island power. The anti-central-island program, blowing aerosol, and cleaning the cornea reduced the formation of steep central islands and blowing nitrogen gas eliminated them. Conclusion: Steep central islands are created by a wide-field ablation process and are probably caused by many factors. Both software and hardware modifications can be used to reduce their formation.

AB - Purpose: To investigate the formation of steep central islands and their reduction under modified experimental conditions. Setting: University Eye Hospital Munster and Schwind Co., Kleinostheim, Germany. Methods: Corneas of enucleated intact bovine eyes were treated with the Schwind Keratom. All experimental conditions were repeated six times in six different corneas. Eight experimental groups were looked at. Fluence was 180 to 200 mJ/cm2. Ablation mode (phototherapeutic keratectomy [PTK] and standard myopic photorefractive keratectomy [PRK]), internal repetition rate (3 to 30 Hz), and ablation diameter (5 to 8 mm) and depth (4 to 15 diopters [D] in PRK) were varied. Modifications to reduce or avoid steep central islands included blowing nitrogen gas and aerosol over the cornea, cleaning the cornea of fluid, and using an anti-central-island software program. Results: In PTK, an increase in the internal repetition rate resulted in a decrease in the height of the steep central island. In standard PRK, increasing refractive correction up to -8.0 D and increasing the ablation diameter resulted in an increase in steep central island power. The anti-central-island program, blowing aerosol, and cleaning the cornea reduced the formation of steep central islands and blowing nitrogen gas eliminated them. Conclusion: Steep central islands are created by a wide-field ablation process and are probably caused by many factors. Both software and hardware modifications can be used to reduce their formation.

UR - http://www.scopus.com/inward/record.url?scp=0031812628&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031812628&partnerID=8YFLogxK

U2 - 10.1016/S0886-3350(98)80040-0

DO - 10.1016/S0886-3350(98)80040-0

M3 - Article

VL - 24

SP - 899

EP - 904

JO - Journal of Cataract and Refractive Surgery

JF - Journal of Cataract and Refractive Surgery

SN - 0886-3350

IS - 7

ER -