Specific method for the determination of genomic DNA methylation by liquid chromatography-electrospray ionization tandem mass spectrometry

Liguo Song, Smitha R. James, Latif Kazim, Adam R Karpf

Research output: Contribution to journalArticle

160 Citations (Scopus)

Abstract

Herein we report a novel method for determining genomic DNA methylation that utilizes liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to measure 5-methyl-2′-deoxycytidine levels following enzymatic hydrolysis of genomic DNA. LC separation of 5-methyl-2′-deoxycytidine from the four deoxyribonucleosides, the four ribonucleosides, and 5-methyl-2′-cytidine, a RNA methylation product, has been achieved within 15 min. In combination with ESI-MS/MS detection, the reported method is highly specific and extremely sensitive with a limit of detection (LOD) of 0.2 fmol and a quantification linearity range from 1 fmol to 20 pmol. Genomic DNA methylation was expressed as the ratio of 5-methyl-2′-deoxycytidine to 2′-deoxyguanosine and was determined directly using 2′-deoxyguanosine as the internal standard. Because deoxycytidine methylation typically ranges from 2 to 6% in mammalian genomes, and pharmacological or genetic manipulations have not achieved levels lower than 0.1%, we validated the assay for methylation levels ranging from 0.05 to 10%. Importantly, both RNA contamination and incomplete DNA hydrolysis had no appreciable effect on 5-methyl-2′-deoxycytidine quantification. LOD studies indicate that only 4 ng of DNA is required for this assay. This LOD should permit the use of this method for applications having limiting amounts of DNA that were not previously candidates for global genomic DNA methylation analysis, e.g., clinical trial samples, or cells collected by laser capture microdissection.

Original languageEnglish (US)
Pages (from-to)504-510
Number of pages7
JournalAnalytical Chemistry
Volume77
Issue number2
DOIs
StatePublished - Jan 15 2005

Fingerprint

5-methyldeoxycytidine
Electrospray ionization
Liquid chromatography
Methylation
Mass spectrometry
Deoxyguanosine
DNA
Assays
Microdissection
RNA
Deoxyribonucleosides
Ribonucleosides
Cytidine
Deoxycytidine
Enzymatic hydrolysis
Hydrolysis
Contamination
Genes
DNA Methylation
Lasers

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Specific method for the determination of genomic DNA methylation by liquid chromatography-electrospray ionization tandem mass spectrometry. / Song, Liguo; James, Smitha R.; Kazim, Latif; Karpf, Adam R.

In: Analytical Chemistry, Vol. 77, No. 2, 15.01.2005, p. 504-510.

Research output: Contribution to journalArticle

@article{5a62c45feeb647d1b90efaa3f84181e2,
title = "Specific method for the determination of genomic DNA methylation by liquid chromatography-electrospray ionization tandem mass spectrometry",
abstract = "Herein we report a novel method for determining genomic DNA methylation that utilizes liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to measure 5-methyl-2′-deoxycytidine levels following enzymatic hydrolysis of genomic DNA. LC separation of 5-methyl-2′-deoxycytidine from the four deoxyribonucleosides, the four ribonucleosides, and 5-methyl-2′-cytidine, a RNA methylation product, has been achieved within 15 min. In combination with ESI-MS/MS detection, the reported method is highly specific and extremely sensitive with a limit of detection (LOD) of 0.2 fmol and a quantification linearity range from 1 fmol to 20 pmol. Genomic DNA methylation was expressed as the ratio of 5-methyl-2′-deoxycytidine to 2′-deoxyguanosine and was determined directly using 2′-deoxyguanosine as the internal standard. Because deoxycytidine methylation typically ranges from 2 to 6{\%} in mammalian genomes, and pharmacological or genetic manipulations have not achieved levels lower than 0.1{\%}, we validated the assay for methylation levels ranging from 0.05 to 10{\%}. Importantly, both RNA contamination and incomplete DNA hydrolysis had no appreciable effect on 5-methyl-2′-deoxycytidine quantification. LOD studies indicate that only 4 ng of DNA is required for this assay. This LOD should permit the use of this method for applications having limiting amounts of DNA that were not previously candidates for global genomic DNA methylation analysis, e.g., clinical trial samples, or cells collected by laser capture microdissection.",
author = "Liguo Song and James, {Smitha R.} and Latif Kazim and Karpf, {Adam R}",
year = "2005",
month = "1",
day = "15",
doi = "10.1021/ac0489420",
language = "English (US)",
volume = "77",
pages = "504--510",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "2",

}

TY - JOUR

T1 - Specific method for the determination of genomic DNA methylation by liquid chromatography-electrospray ionization tandem mass spectrometry

AU - Song, Liguo

AU - James, Smitha R.

AU - Kazim, Latif

AU - Karpf, Adam R

PY - 2005/1/15

Y1 - 2005/1/15

N2 - Herein we report a novel method for determining genomic DNA methylation that utilizes liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to measure 5-methyl-2′-deoxycytidine levels following enzymatic hydrolysis of genomic DNA. LC separation of 5-methyl-2′-deoxycytidine from the four deoxyribonucleosides, the four ribonucleosides, and 5-methyl-2′-cytidine, a RNA methylation product, has been achieved within 15 min. In combination with ESI-MS/MS detection, the reported method is highly specific and extremely sensitive with a limit of detection (LOD) of 0.2 fmol and a quantification linearity range from 1 fmol to 20 pmol. Genomic DNA methylation was expressed as the ratio of 5-methyl-2′-deoxycytidine to 2′-deoxyguanosine and was determined directly using 2′-deoxyguanosine as the internal standard. Because deoxycytidine methylation typically ranges from 2 to 6% in mammalian genomes, and pharmacological or genetic manipulations have not achieved levels lower than 0.1%, we validated the assay for methylation levels ranging from 0.05 to 10%. Importantly, both RNA contamination and incomplete DNA hydrolysis had no appreciable effect on 5-methyl-2′-deoxycytidine quantification. LOD studies indicate that only 4 ng of DNA is required for this assay. This LOD should permit the use of this method for applications having limiting amounts of DNA that were not previously candidates for global genomic DNA methylation analysis, e.g., clinical trial samples, or cells collected by laser capture microdissection.

AB - Herein we report a novel method for determining genomic DNA methylation that utilizes liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) to measure 5-methyl-2′-deoxycytidine levels following enzymatic hydrolysis of genomic DNA. LC separation of 5-methyl-2′-deoxycytidine from the four deoxyribonucleosides, the four ribonucleosides, and 5-methyl-2′-cytidine, a RNA methylation product, has been achieved within 15 min. In combination with ESI-MS/MS detection, the reported method is highly specific and extremely sensitive with a limit of detection (LOD) of 0.2 fmol and a quantification linearity range from 1 fmol to 20 pmol. Genomic DNA methylation was expressed as the ratio of 5-methyl-2′-deoxycytidine to 2′-deoxyguanosine and was determined directly using 2′-deoxyguanosine as the internal standard. Because deoxycytidine methylation typically ranges from 2 to 6% in mammalian genomes, and pharmacological or genetic manipulations have not achieved levels lower than 0.1%, we validated the assay for methylation levels ranging from 0.05 to 10%. Importantly, both RNA contamination and incomplete DNA hydrolysis had no appreciable effect on 5-methyl-2′-deoxycytidine quantification. LOD studies indicate that only 4 ng of DNA is required for this assay. This LOD should permit the use of this method for applications having limiting amounts of DNA that were not previously candidates for global genomic DNA methylation analysis, e.g., clinical trial samples, or cells collected by laser capture microdissection.

UR - http://www.scopus.com/inward/record.url?scp=12244279345&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=12244279345&partnerID=8YFLogxK

U2 - 10.1021/ac0489420

DO - 10.1021/ac0489420

M3 - Article

VL - 77

SP - 504

EP - 510

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 2

ER -