Single-voxel proton MRS of the human brain at 1.5T and 3.0T

Peter B. Barker, David O. Hearshen, Michael D Boska

Research output: Contribution to journalArticle

178 Citations (Scopus)

Abstract

Single-voxel proton spectra of the human brain were recorded in five subjects at both 1.5T and 3.0T using the STEAM pulse sequence. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the centrum semiovale and in phantoms. Spectra were compared in terms of resolution and signal-to-noise ratio (SNR), and transverse relaxation times (T2) were estimated at both field strengths. Spectra at 3T demonstrated a 20% improvement in sensitivity compared to 1.5T at short echo times (TE = 20 msec), which was lower than the theoretical 100% improvement. Spectra at long echo times (TE = 272 msec) exhibited similar SNR at both field strengths. T2 relaxation times were almost twofold shorter at the higher field strength. Spectra in phantoms demonstrated significantly improved resolution at 3T compared to 1.5T, but resolution improvements in in vivo spectra were almost completely offset by increased linewidths at higher field.

Original languageEnglish (US)
Pages (from-to)765-769
Number of pages5
JournalMagnetic Resonance in Medicine
Volume45
Issue number5
DOIs
StatePublished - May 15 2001

Fingerprint

Protons
Brain
Signal-To-Noise Ratio

Keywords

  • 3T
  • Brain
  • Magnetic resonance
  • Proton
  • Spectroscopy

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Single-voxel proton MRS of the human brain at 1.5T and 3.0T. / Barker, Peter B.; Hearshen, David O.; Boska, Michael D.

In: Magnetic Resonance in Medicine, Vol. 45, No. 5, 15.05.2001, p. 765-769.

Research output: Contribution to journalArticle

Barker, Peter B. ; Hearshen, David O. ; Boska, Michael D. / Single-voxel proton MRS of the human brain at 1.5T and 3.0T. In: Magnetic Resonance in Medicine. 2001 ; Vol. 45, No. 5. pp. 765-769.
@article{563da3b7d41a49118745be420ca7f00b,
title = "Single-voxel proton MRS of the human brain at 1.5T and 3.0T",
abstract = "Single-voxel proton spectra of the human brain were recorded in five subjects at both 1.5T and 3.0T using the STEAM pulse sequence. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the centrum semiovale and in phantoms. Spectra were compared in terms of resolution and signal-to-noise ratio (SNR), and transverse relaxation times (T2) were estimated at both field strengths. Spectra at 3T demonstrated a 20{\%} improvement in sensitivity compared to 1.5T at short echo times (TE = 20 msec), which was lower than the theoretical 100{\%} improvement. Spectra at long echo times (TE = 272 msec) exhibited similar SNR at both field strengths. T2 relaxation times were almost twofold shorter at the higher field strength. Spectra in phantoms demonstrated significantly improved resolution at 3T compared to 1.5T, but resolution improvements in in vivo spectra were almost completely offset by increased linewidths at higher field.",
keywords = "3T, Brain, Magnetic resonance, Proton, Spectroscopy",
author = "Barker, {Peter B.} and Hearshen, {David O.} and Boska, {Michael D}",
year = "2001",
month = "5",
day = "15",
doi = "10.1002/mrm.1104",
language = "English (US)",
volume = "45",
pages = "765--769",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

TY - JOUR

T1 - Single-voxel proton MRS of the human brain at 1.5T and 3.0T

AU - Barker, Peter B.

AU - Hearshen, David O.

AU - Boska, Michael D

PY - 2001/5/15

Y1 - 2001/5/15

N2 - Single-voxel proton spectra of the human brain were recorded in five subjects at both 1.5T and 3.0T using the STEAM pulse sequence. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the centrum semiovale and in phantoms. Spectra were compared in terms of resolution and signal-to-noise ratio (SNR), and transverse relaxation times (T2) were estimated at both field strengths. Spectra at 3T demonstrated a 20% improvement in sensitivity compared to 1.5T at short echo times (TE = 20 msec), which was lower than the theoretical 100% improvement. Spectra at long echo times (TE = 272 msec) exhibited similar SNR at both field strengths. T2 relaxation times were almost twofold shorter at the higher field strength. Spectra in phantoms demonstrated significantly improved resolution at 3T compared to 1.5T, but resolution improvements in in vivo spectra were almost completely offset by increased linewidths at higher field.

AB - Single-voxel proton spectra of the human brain were recorded in five subjects at both 1.5T and 3.0T using the STEAM pulse sequence. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the centrum semiovale and in phantoms. Spectra were compared in terms of resolution and signal-to-noise ratio (SNR), and transverse relaxation times (T2) were estimated at both field strengths. Spectra at 3T demonstrated a 20% improvement in sensitivity compared to 1.5T at short echo times (TE = 20 msec), which was lower than the theoretical 100% improvement. Spectra at long echo times (TE = 272 msec) exhibited similar SNR at both field strengths. T2 relaxation times were almost twofold shorter at the higher field strength. Spectra in phantoms demonstrated significantly improved resolution at 3T compared to 1.5T, but resolution improvements in in vivo spectra were almost completely offset by increased linewidths at higher field.

KW - 3T

KW - Brain

KW - Magnetic resonance

KW - Proton

KW - Spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=0035033720&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035033720&partnerID=8YFLogxK

U2 - 10.1002/mrm.1104

DO - 10.1002/mrm.1104

M3 - Article

VL - 45

SP - 765

EP - 769

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -