Single-unit artificial intervertebral disc

Russell Alberts, Arun-Angelo Patil, Dongxue Zhou

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Object. The authors describe a new type of artificial disc called a single-unit artificial disc (SUAD). It is a single-unit disc without components, and there is no fixation system with which to maintain it in the disc space. It is theorized that its shape, hardness, and surface consistency, together with the compressive force exerted by the body's axial load, should be adequate to maintain the position of the disc in the disc space. In this paper the authors present their results of the kinematic tests in which the stability and integrity of the SUADs was tested. Methods. Panorobot was used for kinematic test fixture for fatigue testing for different types of SUAD. The test was performed after placing the disc between the C-5 and C-6 vertebral bodies (VBs) obtained from a cadaver. Eight pounds of weight was placed on the top of the container housing the C-5 VB to account for the weight of the head. The robot performed the following movements: 1) flexion-extension, 4.7° each; 2) lateral left-right bending, ± 2.1°; and 3) coupled rotation, ± 3.8°. Two flat discs (FDs) of 85 durometer (D), four 30D FD, two recess-edged discs (REDs) of 85D, and four custom-designed discs (CDDs) (custom molded to the disc space) of 30D were tested. None of the discs showed cracks or breakage at the end of the study. After 1 million cycles of excursions all 85D and 30D FD, and both 85D REDs showed weight loss. The 30D CDDs showed minimal weight gain at 1 million cycles. One of the CDDs, tested up to 5 million cycles, did lose weight at 5 million cycles. One 85D FD was extruded after 0.2 million cycles and one 85D RED rotated within the disc space. All other discs maintained their position in the disc space. Dimensional changes were minimal. Scanning electron microscopy of particles collected from one 30D CDD sample after 1 million cycles showed rough irregular granular particles 1 to 600 μm in diameter. Conclusions. These findings show that a 30D SUAD can maintain its position in the disc space without any anchoring device. Furthermore, at 1 million cycles of testing of 30 D SUAD, FDs did as well as the CDDs. This may be because softer discs mold to changes in dimension of the disc space. In addition the softer discs tend to wear less than the harder ones. Further fatigue study of 10 million cycles is needed to determine long-term efficacy, and the effects of wear on particles surrounding the joints need to be studied.

Original languageEnglish (US)
Pages (from-to)95-100
Number of pages6
JournalJournal of neurosurgery
Volume101
Issue number1 SUPPL.
StatePublished - Jul 1 2004

Fingerprint

Intervertebral Disc
Biomechanical Phenomena
Weights and Measures
Fatigue
Hardness
Cadaver
Electron Scanning Microscopy
Weight Gain
Weight Loss
Fungi
Joints
Head
Equipment and Supplies

Keywords

  • Artificial disc
  • Fatigue test
  • Silicone
  • Vertebral body

ASJC Scopus subject areas

  • Surgery
  • Clinical Neurology

Cite this

Alberts, R., Patil, A-A., & Zhou, D. (2004). Single-unit artificial intervertebral disc. Journal of neurosurgery, 101(1 SUPPL.), 95-100.

Single-unit artificial intervertebral disc. / Alberts, Russell; Patil, Arun-Angelo; Zhou, Dongxue.

In: Journal of neurosurgery, Vol. 101, No. 1 SUPPL., 01.07.2004, p. 95-100.

Research output: Contribution to journalArticle

Alberts, R, Patil, A-A & Zhou, D 2004, 'Single-unit artificial intervertebral disc', Journal of neurosurgery, vol. 101, no. 1 SUPPL., pp. 95-100.
Alberts R, Patil A-A, Zhou D. Single-unit artificial intervertebral disc. Journal of neurosurgery. 2004 Jul 1;101(1 SUPPL.):95-100.
Alberts, Russell ; Patil, Arun-Angelo ; Zhou, Dongxue. / Single-unit artificial intervertebral disc. In: Journal of neurosurgery. 2004 ; Vol. 101, No. 1 SUPPL. pp. 95-100.
@article{51e724316afe43c58bf9c20916b24ac1,
title = "Single-unit artificial intervertebral disc",
abstract = "Object. The authors describe a new type of artificial disc called a single-unit artificial disc (SUAD). It is a single-unit disc without components, and there is no fixation system with which to maintain it in the disc space. It is theorized that its shape, hardness, and surface consistency, together with the compressive force exerted by the body's axial load, should be adequate to maintain the position of the disc in the disc space. In this paper the authors present their results of the kinematic tests in which the stability and integrity of the SUADs was tested. Methods. Panorobot was used for kinematic test fixture for fatigue testing for different types of SUAD. The test was performed after placing the disc between the C-5 and C-6 vertebral bodies (VBs) obtained from a cadaver. Eight pounds of weight was placed on the top of the container housing the C-5 VB to account for the weight of the head. The robot performed the following movements: 1) flexion-extension, 4.7° each; 2) lateral left-right bending, ± 2.1°; and 3) coupled rotation, ± 3.8°. Two flat discs (FDs) of 85 durometer (D), four 30D FD, two recess-edged discs (REDs) of 85D, and four custom-designed discs (CDDs) (custom molded to the disc space) of 30D were tested. None of the discs showed cracks or breakage at the end of the study. After 1 million cycles of excursions all 85D and 30D FD, and both 85D REDs showed weight loss. The 30D CDDs showed minimal weight gain at 1 million cycles. One of the CDDs, tested up to 5 million cycles, did lose weight at 5 million cycles. One 85D FD was extruded after 0.2 million cycles and one 85D RED rotated within the disc space. All other discs maintained their position in the disc space. Dimensional changes were minimal. Scanning electron microscopy of particles collected from one 30D CDD sample after 1 million cycles showed rough irregular granular particles 1 to 600 μm in diameter. Conclusions. These findings show that a 30D SUAD can maintain its position in the disc space without any anchoring device. Furthermore, at 1 million cycles of testing of 30 D SUAD, FDs did as well as the CDDs. This may be because softer discs mold to changes in dimension of the disc space. In addition the softer discs tend to wear less than the harder ones. Further fatigue study of 10 million cycles is needed to determine long-term efficacy, and the effects of wear on particles surrounding the joints need to be studied.",
keywords = "Artificial disc, Fatigue test, Silicone, Vertebral body",
author = "Russell Alberts and Arun-Angelo Patil and Dongxue Zhou",
year = "2004",
month = "7",
day = "1",
language = "English (US)",
volume = "101",
pages = "95--100",
journal = "Journal of Neurosurgery",
issn = "0022-3085",
publisher = "American Association of Neurological Surgeons",
number = "1 SUPPL.",

}

TY - JOUR

T1 - Single-unit artificial intervertebral disc

AU - Alberts, Russell

AU - Patil, Arun-Angelo

AU - Zhou, Dongxue

PY - 2004/7/1

Y1 - 2004/7/1

N2 - Object. The authors describe a new type of artificial disc called a single-unit artificial disc (SUAD). It is a single-unit disc without components, and there is no fixation system with which to maintain it in the disc space. It is theorized that its shape, hardness, and surface consistency, together with the compressive force exerted by the body's axial load, should be adequate to maintain the position of the disc in the disc space. In this paper the authors present their results of the kinematic tests in which the stability and integrity of the SUADs was tested. Methods. Panorobot was used for kinematic test fixture for fatigue testing for different types of SUAD. The test was performed after placing the disc between the C-5 and C-6 vertebral bodies (VBs) obtained from a cadaver. Eight pounds of weight was placed on the top of the container housing the C-5 VB to account for the weight of the head. The robot performed the following movements: 1) flexion-extension, 4.7° each; 2) lateral left-right bending, ± 2.1°; and 3) coupled rotation, ± 3.8°. Two flat discs (FDs) of 85 durometer (D), four 30D FD, two recess-edged discs (REDs) of 85D, and four custom-designed discs (CDDs) (custom molded to the disc space) of 30D were tested. None of the discs showed cracks or breakage at the end of the study. After 1 million cycles of excursions all 85D and 30D FD, and both 85D REDs showed weight loss. The 30D CDDs showed minimal weight gain at 1 million cycles. One of the CDDs, tested up to 5 million cycles, did lose weight at 5 million cycles. One 85D FD was extruded after 0.2 million cycles and one 85D RED rotated within the disc space. All other discs maintained their position in the disc space. Dimensional changes were minimal. Scanning electron microscopy of particles collected from one 30D CDD sample after 1 million cycles showed rough irregular granular particles 1 to 600 μm in diameter. Conclusions. These findings show that a 30D SUAD can maintain its position in the disc space without any anchoring device. Furthermore, at 1 million cycles of testing of 30 D SUAD, FDs did as well as the CDDs. This may be because softer discs mold to changes in dimension of the disc space. In addition the softer discs tend to wear less than the harder ones. Further fatigue study of 10 million cycles is needed to determine long-term efficacy, and the effects of wear on particles surrounding the joints need to be studied.

AB - Object. The authors describe a new type of artificial disc called a single-unit artificial disc (SUAD). It is a single-unit disc without components, and there is no fixation system with which to maintain it in the disc space. It is theorized that its shape, hardness, and surface consistency, together with the compressive force exerted by the body's axial load, should be adequate to maintain the position of the disc in the disc space. In this paper the authors present their results of the kinematic tests in which the stability and integrity of the SUADs was tested. Methods. Panorobot was used for kinematic test fixture for fatigue testing for different types of SUAD. The test was performed after placing the disc between the C-5 and C-6 vertebral bodies (VBs) obtained from a cadaver. Eight pounds of weight was placed on the top of the container housing the C-5 VB to account for the weight of the head. The robot performed the following movements: 1) flexion-extension, 4.7° each; 2) lateral left-right bending, ± 2.1°; and 3) coupled rotation, ± 3.8°. Two flat discs (FDs) of 85 durometer (D), four 30D FD, two recess-edged discs (REDs) of 85D, and four custom-designed discs (CDDs) (custom molded to the disc space) of 30D were tested. None of the discs showed cracks or breakage at the end of the study. After 1 million cycles of excursions all 85D and 30D FD, and both 85D REDs showed weight loss. The 30D CDDs showed minimal weight gain at 1 million cycles. One of the CDDs, tested up to 5 million cycles, did lose weight at 5 million cycles. One 85D FD was extruded after 0.2 million cycles and one 85D RED rotated within the disc space. All other discs maintained their position in the disc space. Dimensional changes were minimal. Scanning electron microscopy of particles collected from one 30D CDD sample after 1 million cycles showed rough irregular granular particles 1 to 600 μm in diameter. Conclusions. These findings show that a 30D SUAD can maintain its position in the disc space without any anchoring device. Furthermore, at 1 million cycles of testing of 30 D SUAD, FDs did as well as the CDDs. This may be because softer discs mold to changes in dimension of the disc space. In addition the softer discs tend to wear less than the harder ones. Further fatigue study of 10 million cycles is needed to determine long-term efficacy, and the effects of wear on particles surrounding the joints need to be studied.

KW - Artificial disc

KW - Fatigue test

KW - Silicone

KW - Vertebral body

UR - http://www.scopus.com/inward/record.url?scp=3042637382&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=3042637382&partnerID=8YFLogxK

M3 - Article

VL - 101

SP - 95

EP - 100

JO - Journal of Neurosurgery

JF - Journal of Neurosurgery

SN - 0022-3085

IS - 1 SUPPL.

ER -