Shielded radiography with a laser-driven MeV-energy X-ray source

Shouyuan Chen, Grigory Golovin, Cameron Miller, Daniel Haden, Sudeep Banerjee, Ping Zhang, Cheng Liu, Jun Zhang, Baozhen Zhao, Shaun Clarke, Sara Pozzi, Donald Umstadter

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 107 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ∼100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam's inherently low-divergence angle (∼mrad) is advantageous and effective for interrogation at standoff distance. These results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

Original languageEnglish (US)
Pages (from-to)217-223
Number of pages7
JournalNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
Volume366
DOIs
StatePublished - Jan 1 2016

Fingerprint

Radiography
radiography
X rays
Lasers
lasers
x rays
energy
Light sources
light sources
Compton scattering
dosage
simulation
interrogation
image contrast
Full width at half maximum
pulses
bremsstrahlung
Uranium
uranium
shot

Keywords

  • Inverse Compton
  • Laser
  • Monte Car
  • Radiography

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Cite this

Shielded radiography with a laser-driven MeV-energy X-ray source. / Chen, Shouyuan; Golovin, Grigory; Miller, Cameron; Haden, Daniel; Banerjee, Sudeep; Zhang, Ping; Liu, Cheng; Zhang, Jun; Zhao, Baozhen; Clarke, Shaun; Pozzi, Sara; Umstadter, Donald.

In: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, Vol. 366, 01.01.2016, p. 217-223.

Research output: Contribution to journalArticle

Chen, Shouyuan ; Golovin, Grigory ; Miller, Cameron ; Haden, Daniel ; Banerjee, Sudeep ; Zhang, Ping ; Liu, Cheng ; Zhang, Jun ; Zhao, Baozhen ; Clarke, Shaun ; Pozzi, Sara ; Umstadter, Donald. / Shielded radiography with a laser-driven MeV-energy X-ray source. In: Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms. 2016 ; Vol. 366. pp. 217-223.
@article{806d804cf26d434db25be8c2ca5b0bd1,
title = "Shielded radiography with a laser-driven MeV-energy X-ray source",
abstract = "We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45{\%} (FWHM) and 107 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ∼100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam's inherently low-divergence angle (∼mrad) is advantageous and effective for interrogation at standoff distance. These results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.",
keywords = "Inverse Compton, Laser, Monte Car, Radiography",
author = "Shouyuan Chen and Grigory Golovin and Cameron Miller and Daniel Haden and Sudeep Banerjee and Ping Zhang and Cheng Liu and Jun Zhang and Baozhen Zhao and Shaun Clarke and Sara Pozzi and Donald Umstadter",
year = "2016",
month = "1",
day = "1",
doi = "10.1016/j.nimb.2015.11.007",
language = "English (US)",
volume = "366",
pages = "217--223",
journal = "Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",
publisher = "Elsevier",

}

TY - JOUR

T1 - Shielded radiography with a laser-driven MeV-energy X-ray source

AU - Chen, Shouyuan

AU - Golovin, Grigory

AU - Miller, Cameron

AU - Haden, Daniel

AU - Banerjee, Sudeep

AU - Zhang, Ping

AU - Liu, Cheng

AU - Zhang, Jun

AU - Zhao, Baozhen

AU - Clarke, Shaun

AU - Pozzi, Sara

AU - Umstadter, Donald

PY - 2016/1/1

Y1 - 2016/1/1

N2 - We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 107 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ∼100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam's inherently low-divergence angle (∼mrad) is advantageous and effective for interrogation at standoff distance. These results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

AB - We report the results of experimental and numerical-simulation studies of shielded radiography using narrowband MeV-energy X-rays from a compact all-laser-driven inverse-Compton-scattering X-ray light source. This recently developed X-ray light source is based on a laser-wakefield accelerator with ultra-high-field gradient (GeV/cm). We demonstrate experimentally high-quality radiographic imaging (image contrast of 0.4 and signal-to-noise ratio of 2:1) of a target composed of 8-mm thick depleted uranium shielded by 80-mm thick steel, using a 6-MeV X-ray beam with a spread of 45% (FWHM) and 107 photons in a single shot. The corresponding dose of the X-ray pulse measured in front of the target is ∼100 nGy/pulse. Simulations performed using the Monte-Carlo code MCNPX accurately reproduce the experimental results. These simulations also demonstrate that the narrow bandwidth of the Compton X-ray source operating at 6 and 9 MeV leads to a reduction of deposited dose as compared to broadband bremsstrahlung sources with the same end-point energy. The X-ray beam's inherently low-divergence angle (∼mrad) is advantageous and effective for interrogation at standoff distance. These results demonstrate significant benefits of all-laser driven Compton X-rays for shielded radiography.

KW - Inverse Compton

KW - Laser

KW - Monte Car

KW - Radiography

UR - http://www.scopus.com/inward/record.url?scp=84947757517&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84947757517&partnerID=8YFLogxK

U2 - 10.1016/j.nimb.2015.11.007

DO - 10.1016/j.nimb.2015.11.007

M3 - Article

AN - SCOPUS:84947757517

VL - 366

SP - 217

EP - 223

JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

ER -