Sensitivity of flexural and torsional vibration modes of atomic force microscope cantilevers to surface stiffness variations

J. A. Turner, J. S. Wiehn

Research output: Contribution to journalConference article

144 Citations (Scopus)

Abstract

Dynamic modes of atomic-force microscopy offer new possibilities for imaging because of the availability of the various vibrational modes of the probes. However, each mode has a different sensitivity to variations in surface stiffness. This sensitivity directly controls the image contrast. Low-stiffness cantilevers have typically been unusable for imaging of stiff materials because of the lack of sensitivity of the first flexural mode. In this paper, the sensitivities of the flexural and torsional modes are derived. Closed-form expressions are obtained for cantilevers with constant cross sections. For cantilevers with other shapes, an approximate solution is developed using the method of Rayleigh-Ritz. The interaction of the cantilever with the surface is modelled by linear springs, which restricts the results to experiments involving low-amplitude excitations. Both flexural and torsional vibration modes are considered. For given nominal values of surface and AFM probe properties, the appropriate mode for highest contrast may be predicted.

Original languageEnglish (US)
Pages (from-to)322-330
Number of pages9
JournalNanotechnology
Volume12
Issue number3
DOIs
StatePublished - Sep 1 2001
Event8th Foresight Conference on Molecular Nanotechnology - Bethesda, MR, United States
Duration: Nov 2 2000Nov 5 2000

Fingerprint

torsional vibration
vibration mode
stiffness
Microscopes
microscopes
Stiffness
vibration
sensitivity
Imaging techniques
atomic force microscopy
Atomic force microscopy
Availability
probes
image contrast
availability
Experiments
cross sections
approximation
excitation
interactions

ASJC Scopus subject areas

  • Bioengineering
  • Chemistry(all)
  • Materials Science(all)
  • Mechanics of Materials
  • Mechanical Engineering
  • Electrical and Electronic Engineering

Cite this

Sensitivity of flexural and torsional vibration modes of atomic force microscope cantilevers to surface stiffness variations. / Turner, J. A.; Wiehn, J. S.

In: Nanotechnology, Vol. 12, No. 3, 01.09.2001, p. 322-330.

Research output: Contribution to journalConference article

@article{236955c8002b4d6a80b0945d654a10d4,
title = "Sensitivity of flexural and torsional vibration modes of atomic force microscope cantilevers to surface stiffness variations",
abstract = "Dynamic modes of atomic-force microscopy offer new possibilities for imaging because of the availability of the various vibrational modes of the probes. However, each mode has a different sensitivity to variations in surface stiffness. This sensitivity directly controls the image contrast. Low-stiffness cantilevers have typically been unusable for imaging of stiff materials because of the lack of sensitivity of the first flexural mode. In this paper, the sensitivities of the flexural and torsional modes are derived. Closed-form expressions are obtained for cantilevers with constant cross sections. For cantilevers with other shapes, an approximate solution is developed using the method of Rayleigh-Ritz. The interaction of the cantilever with the surface is modelled by linear springs, which restricts the results to experiments involving low-amplitude excitations. Both flexural and torsional vibration modes are considered. For given nominal values of surface and AFM probe properties, the appropriate mode for highest contrast may be predicted.",
author = "Turner, {J. A.} and Wiehn, {J. S.}",
year = "2001",
month = "9",
day = "1",
doi = "10.1088/0957-4484/12/3/321",
language = "English (US)",
volume = "12",
pages = "322--330",
journal = "Nanotechnology",
issn = "0957-4484",
publisher = "IOP Publishing Ltd.",
number = "3",

}

TY - JOUR

T1 - Sensitivity of flexural and torsional vibration modes of atomic force microscope cantilevers to surface stiffness variations

AU - Turner, J. A.

AU - Wiehn, J. S.

PY - 2001/9/1

Y1 - 2001/9/1

N2 - Dynamic modes of atomic-force microscopy offer new possibilities for imaging because of the availability of the various vibrational modes of the probes. However, each mode has a different sensitivity to variations in surface stiffness. This sensitivity directly controls the image contrast. Low-stiffness cantilevers have typically been unusable for imaging of stiff materials because of the lack of sensitivity of the first flexural mode. In this paper, the sensitivities of the flexural and torsional modes are derived. Closed-form expressions are obtained for cantilevers with constant cross sections. For cantilevers with other shapes, an approximate solution is developed using the method of Rayleigh-Ritz. The interaction of the cantilever with the surface is modelled by linear springs, which restricts the results to experiments involving low-amplitude excitations. Both flexural and torsional vibration modes are considered. For given nominal values of surface and AFM probe properties, the appropriate mode for highest contrast may be predicted.

AB - Dynamic modes of atomic-force microscopy offer new possibilities for imaging because of the availability of the various vibrational modes of the probes. However, each mode has a different sensitivity to variations in surface stiffness. This sensitivity directly controls the image contrast. Low-stiffness cantilevers have typically been unusable for imaging of stiff materials because of the lack of sensitivity of the first flexural mode. In this paper, the sensitivities of the flexural and torsional modes are derived. Closed-form expressions are obtained for cantilevers with constant cross sections. For cantilevers with other shapes, an approximate solution is developed using the method of Rayleigh-Ritz. The interaction of the cantilever with the surface is modelled by linear springs, which restricts the results to experiments involving low-amplitude excitations. Both flexural and torsional vibration modes are considered. For given nominal values of surface and AFM probe properties, the appropriate mode for highest contrast may be predicted.

UR - http://www.scopus.com/inward/record.url?scp=0035442763&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035442763&partnerID=8YFLogxK

U2 - 10.1088/0957-4484/12/3/321

DO - 10.1088/0957-4484/12/3/321

M3 - Conference article

AN - SCOPUS:0035442763

VL - 12

SP - 322

EP - 330

JO - Nanotechnology

JF - Nanotechnology

SN - 0957-4484

IS - 3

ER -