A simple flow-injection system, suitable for solution flow rates at microliters-per-minute, has been combined with fast-scan voltammetry for selective determination of methylmercury. A thin Hg film was formed at a Pt microelectrode prior to the measurement. Detection of methylmercury is carried out by measuring the oxidation of methylmercury radicals that have been generated at the Hg microelectrode. At slow scan rates, the electrogenerated methylmercury radicals undergo a follow-up dimerization reaction to form dimethyldimercury (ErC2i mechanism). At fast scan rates, it was found that methylmercury radicals can be quantitatively reoxidized (reversible electron-transfer). Optimization of the experimental conditions of the system was performed based on studies of the relationship between the scan rate and the dimerization rate of the methylmercury radical. Under optimized conditions, detection level of subnanomole was obtained with a sample consumption of less than 10 μL and the concentration detection limit for methylmercury at 50 V/s was estimated to be about 0.56 μM. To demonstrate the applicability of this method to automatic analyses, repetitive fast-scan cyclic voltammetry was conducted in conjunction with multiple sample injections. Determination of methylmercury in the presence of excess inorganic mercury was also conducted. This new approach to methylmercury determination was successfully applied to the analysis of elevated dogfish muscle samples.

Original languageEnglish (US)
Pages (from-to)926-930
Number of pages5
JournalElectroanalysis
Volume10
Issue number13
DOIs
StatePublished - Jan 1 1998
Externally publishedYes

Fingerprint

Dimerization
Microelectrodes
Voltammetry
Mercury
Cyclic voltammetry
Muscle
Flow rate
Thin films
Oxidation
Electrons

Keywords

  • Fast-scan voltammetry
  • Flow-injection analysis
  • Methylmercury
  • Platinum-based mercury microelectrodes

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Cite this

Selective Determination of Methylmercury by Flow-Injection Fast-Scan Voltammetry. / Lai, Rebecca; Huang, Eva L.; Zhou, Feimeng; Wipf, David O.

In: Electroanalysis, Vol. 10, No. 13, 01.01.1998, p. 926-930.

Research output: Contribution to journalArticle

Lai, Rebecca ; Huang, Eva L. ; Zhou, Feimeng ; Wipf, David O. / Selective Determination of Methylmercury by Flow-Injection Fast-Scan Voltammetry. In: Electroanalysis. 1998 ; Vol. 10, No. 13. pp. 926-930.
@article{b1639da441ec4187a1573dc62d1205a6,
title = "Selective Determination of Methylmercury by Flow-Injection Fast-Scan Voltammetry",
abstract = "A simple flow-injection system, suitable for solution flow rates at microliters-per-minute, has been combined with fast-scan voltammetry for selective determination of methylmercury. A thin Hg film was formed at a Pt microelectrode prior to the measurement. Detection of methylmercury is carried out by measuring the oxidation of methylmercury radicals that have been generated at the Hg microelectrode. At slow scan rates, the electrogenerated methylmercury radicals undergo a follow-up dimerization reaction to form dimethyldimercury (ErC2i mechanism). At fast scan rates, it was found that methylmercury radicals can be quantitatively reoxidized (reversible electron-transfer). Optimization of the experimental conditions of the system was performed based on studies of the relationship between the scan rate and the dimerization rate of the methylmercury radical. Under optimized conditions, detection level of subnanomole was obtained with a sample consumption of less than 10 μL and the concentration detection limit for methylmercury at 50 V/s was estimated to be about 0.56 μM. To demonstrate the applicability of this method to automatic analyses, repetitive fast-scan cyclic voltammetry was conducted in conjunction with multiple sample injections. Determination of methylmercury in the presence of excess inorganic mercury was also conducted. This new approach to methylmercury determination was successfully applied to the analysis of elevated dogfish muscle samples.",
keywords = "Fast-scan voltammetry, Flow-injection analysis, Methylmercury, Platinum-based mercury microelectrodes",
author = "Rebecca Lai and Huang, {Eva L.} and Feimeng Zhou and Wipf, {David O.}",
year = "1998",
month = "1",
day = "1",
doi = "10.1002/(SICI)1521-4109(199810)10:13<926::AID-ELAN926>3.0.CO;2-L",
language = "English (US)",
volume = "10",
pages = "926--930",
journal = "Electroanalysis",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "13",

}

TY - JOUR

T1 - Selective Determination of Methylmercury by Flow-Injection Fast-Scan Voltammetry

AU - Lai, Rebecca

AU - Huang, Eva L.

AU - Zhou, Feimeng

AU - Wipf, David O.

PY - 1998/1/1

Y1 - 1998/1/1

N2 - A simple flow-injection system, suitable for solution flow rates at microliters-per-minute, has been combined with fast-scan voltammetry for selective determination of methylmercury. A thin Hg film was formed at a Pt microelectrode prior to the measurement. Detection of methylmercury is carried out by measuring the oxidation of methylmercury radicals that have been generated at the Hg microelectrode. At slow scan rates, the electrogenerated methylmercury radicals undergo a follow-up dimerization reaction to form dimethyldimercury (ErC2i mechanism). At fast scan rates, it was found that methylmercury radicals can be quantitatively reoxidized (reversible electron-transfer). Optimization of the experimental conditions of the system was performed based on studies of the relationship between the scan rate and the dimerization rate of the methylmercury radical. Under optimized conditions, detection level of subnanomole was obtained with a sample consumption of less than 10 μL and the concentration detection limit for methylmercury at 50 V/s was estimated to be about 0.56 μM. To demonstrate the applicability of this method to automatic analyses, repetitive fast-scan cyclic voltammetry was conducted in conjunction with multiple sample injections. Determination of methylmercury in the presence of excess inorganic mercury was also conducted. This new approach to methylmercury determination was successfully applied to the analysis of elevated dogfish muscle samples.

AB - A simple flow-injection system, suitable for solution flow rates at microliters-per-minute, has been combined with fast-scan voltammetry for selective determination of methylmercury. A thin Hg film was formed at a Pt microelectrode prior to the measurement. Detection of methylmercury is carried out by measuring the oxidation of methylmercury radicals that have been generated at the Hg microelectrode. At slow scan rates, the electrogenerated methylmercury radicals undergo a follow-up dimerization reaction to form dimethyldimercury (ErC2i mechanism). At fast scan rates, it was found that methylmercury radicals can be quantitatively reoxidized (reversible electron-transfer). Optimization of the experimental conditions of the system was performed based on studies of the relationship between the scan rate and the dimerization rate of the methylmercury radical. Under optimized conditions, detection level of subnanomole was obtained with a sample consumption of less than 10 μL and the concentration detection limit for methylmercury at 50 V/s was estimated to be about 0.56 μM. To demonstrate the applicability of this method to automatic analyses, repetitive fast-scan cyclic voltammetry was conducted in conjunction with multiple sample injections. Determination of methylmercury in the presence of excess inorganic mercury was also conducted. This new approach to methylmercury determination was successfully applied to the analysis of elevated dogfish muscle samples.

KW - Fast-scan voltammetry

KW - Flow-injection analysis

KW - Methylmercury

KW - Platinum-based mercury microelectrodes

UR - http://www.scopus.com/inward/record.url?scp=0001396586&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0001396586&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1521-4109(199810)10:13<926::AID-ELAN926>3.0.CO;2-L

DO - 10.1002/(SICI)1521-4109(199810)10:13<926::AID-ELAN926>3.0.CO;2-L

M3 - Article

AN - SCOPUS:0001396586

VL - 10

SP - 926

EP - 930

JO - Electroanalysis

JF - Electroanalysis

SN - 1040-0397

IS - 13

ER -