The influence of wavelet compression on calculated dose distribution is investigated as regards to CT-based radiotherapy planning. Chest CT images for radiotherapy were compressed and a treatment plan was constructed to generate a dose distribution within the CT image. The compressed images were analyzed using dose volume histograms (DVH) and compared to DVHs generated for uncompressed images. The lossy wavelet compression irreversibly changes pixel values in the CT, giving rise to errors in the dose calculations performed by treatment planning systems that account for tissue inhomogeneities in the image.

Original languageEnglish (US)
Title of host publicationProceedings of SPIE - The International Society for Optical Engineering
PublisherSociety of Photo-Optical Instrumentation Engineers
Pages1147-1157
Number of pages11
Volume3661
EditionII
StatePublished - 1999
EventProceedings of the 1999 Medical Imaging - Image Processing - San Diego, CA, USA
Duration: Feb 22 1999Feb 25 1999

Other

OtherProceedings of the 1999 Medical Imaging - Image Processing
CitySan Diego, CA, USA
Period2/22/992/25/99

Fingerprint

Oncology
Radiotherapy
Image compression
planning
Radiation
Planning
radiation
dosage
Pixels
Tissue
radiation therapy
chest
histograms
inhomogeneity
pixels

ASJC Scopus subject areas

  • Electrical and Electronic Engineering
  • Condensed Matter Physics

Cite this

Smith, C. L., Chu, W. K., Wobig, R., Chao, H., & Enke, C. A. (1999). Results of wavelet image compression on CT-based clinical radiation oncology treatment planning. In Proceedings of SPIE - The International Society for Optical Engineering (II ed., Vol. 3661, pp. 1147-1157). Society of Photo-Optical Instrumentation Engineers.

Results of wavelet image compression on CT-based clinical radiation oncology treatment planning. / Smith, Charles L.; Chu, Wei Kom; Wobig, Randy; Chao, Hongyang; Enke, Charles Arthur.

Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3661 II. ed. Society of Photo-Optical Instrumentation Engineers, 1999. p. 1147-1157.

Research output: Chapter in Book/Report/Conference proceedingChapter

Smith, CL, Chu, WK, Wobig, R, Chao, H & Enke, CA 1999, Results of wavelet image compression on CT-based clinical radiation oncology treatment planning. in Proceedings of SPIE - The International Society for Optical Engineering. II edn, vol. 3661, Society of Photo-Optical Instrumentation Engineers, pp. 1147-1157, Proceedings of the 1999 Medical Imaging - Image Processing, San Diego, CA, USA, 2/22/99.
Smith CL, Chu WK, Wobig R, Chao H, Enke CA. Results of wavelet image compression on CT-based clinical radiation oncology treatment planning. In Proceedings of SPIE - The International Society for Optical Engineering. II ed. Vol. 3661. Society of Photo-Optical Instrumentation Engineers. 1999. p. 1147-1157
Smith, Charles L. ; Chu, Wei Kom ; Wobig, Randy ; Chao, Hongyang ; Enke, Charles Arthur. / Results of wavelet image compression on CT-based clinical radiation oncology treatment planning. Proceedings of SPIE - The International Society for Optical Engineering. Vol. 3661 II. ed. Society of Photo-Optical Instrumentation Engineers, 1999. pp. 1147-1157
@inbook{b408ddd428c7468188a38afb022aaf7a,
title = "Results of wavelet image compression on CT-based clinical radiation oncology treatment planning",
abstract = "The influence of wavelet compression on calculated dose distribution is investigated as regards to CT-based radiotherapy planning. Chest CT images for radiotherapy were compressed and a treatment plan was constructed to generate a dose distribution within the CT image. The compressed images were analyzed using dose volume histograms (DVH) and compared to DVHs generated for uncompressed images. The lossy wavelet compression irreversibly changes pixel values in the CT, giving rise to errors in the dose calculations performed by treatment planning systems that account for tissue inhomogeneities in the image.",
author = "Smith, {Charles L.} and Chu, {Wei Kom} and Randy Wobig and Hongyang Chao and Enke, {Charles Arthur}",
year = "1999",
language = "English (US)",
volume = "3661",
pages = "1147--1157",
booktitle = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "Society of Photo-Optical Instrumentation Engineers",
edition = "II",

}

TY - CHAP

T1 - Results of wavelet image compression on CT-based clinical radiation oncology treatment planning

AU - Smith, Charles L.

AU - Chu, Wei Kom

AU - Wobig, Randy

AU - Chao, Hongyang

AU - Enke, Charles Arthur

PY - 1999

Y1 - 1999

N2 - The influence of wavelet compression on calculated dose distribution is investigated as regards to CT-based radiotherapy planning. Chest CT images for radiotherapy were compressed and a treatment plan was constructed to generate a dose distribution within the CT image. The compressed images were analyzed using dose volume histograms (DVH) and compared to DVHs generated for uncompressed images. The lossy wavelet compression irreversibly changes pixel values in the CT, giving rise to errors in the dose calculations performed by treatment planning systems that account for tissue inhomogeneities in the image.

AB - The influence of wavelet compression on calculated dose distribution is investigated as regards to CT-based radiotherapy planning. Chest CT images for radiotherapy were compressed and a treatment plan was constructed to generate a dose distribution within the CT image. The compressed images were analyzed using dose volume histograms (DVH) and compared to DVHs generated for uncompressed images. The lossy wavelet compression irreversibly changes pixel values in the CT, giving rise to errors in the dose calculations performed by treatment planning systems that account for tissue inhomogeneities in the image.

UR - http://www.scopus.com/inward/record.url?scp=0032594159&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032594159&partnerID=8YFLogxK

M3 - Chapter

AN - SCOPUS:0032594159

VL - 3661

SP - 1147

EP - 1157

BT - Proceedings of SPIE - The International Society for Optical Engineering

PB - Society of Photo-Optical Instrumentation Engineers

ER -