Renal blood flow and intrarenal distribution of blood flow after decapsulation in the postischemic kidney

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Previous reports suggest the value of renal decapsulation in the prevention of renal failure after acute ischemia. It has been suggested that this response is due to a release of 'compartmental' pressure resulting in increased blood flow to the decapsulated kidney. Ten dogs were evaluated following 90 minutes of renal ischemia created by occlusion of the suprarenal aorta. Each animal underwent random unilateral decapsulation, with the contralateral kidney acting as control. Labeled 15 micron microspheres (Se85 and Ce141) were injected into the left ventricle at 15 minutes and one hour following decapsulation in six dogs. In the remaining animals the injection was carried out at 15 minutes and 48 hours. No difference in renal blood flow was found between decapsulated and control kidneys in either group. Similarly, using sectioned kidneys no difference in intrarenal distribution of blood flow was found. These data suggest that the effects caused by decapsulation are not due to hemodynamic alterations.

Original languageEnglish (US)
Pages (from-to)456-459
Number of pages4
JournalAnnals of surgery
Volume191
Issue number4
DOIs
StatePublished - Jan 1 1980

Fingerprint

Renal Circulation
Kidney
Ischemia
Dogs
Microspheres
Acute Kidney Injury
Heart Ventricles
Aorta
Hemodynamics
Pressure
Injections

ASJC Scopus subject areas

  • Surgery

Cite this

Renal blood flow and intrarenal distribution of blood flow after decapsulation in the postischemic kidney. / Stothert, J. C.

In: Annals of surgery, Vol. 191, No. 4, 01.01.1980, p. 456-459.

Research output: Contribution to journalArticle

@article{a8ebe268c91f412b92559dd42c51502b,
title = "Renal blood flow and intrarenal distribution of blood flow after decapsulation in the postischemic kidney",
abstract = "Previous reports suggest the value of renal decapsulation in the prevention of renal failure after acute ischemia. It has been suggested that this response is due to a release of 'compartmental' pressure resulting in increased blood flow to the decapsulated kidney. Ten dogs were evaluated following 90 minutes of renal ischemia created by occlusion of the suprarenal aorta. Each animal underwent random unilateral decapsulation, with the contralateral kidney acting as control. Labeled 15 micron microspheres (Se85 and Ce141) were injected into the left ventricle at 15 minutes and one hour following decapsulation in six dogs. In the remaining animals the injection was carried out at 15 minutes and 48 hours. No difference in renal blood flow was found between decapsulated and control kidneys in either group. Similarly, using sectioned kidneys no difference in intrarenal distribution of blood flow was found. These data suggest that the effects caused by decapsulation are not due to hemodynamic alterations.",
author = "Stothert, {J. C.}",
year = "1980",
month = "1",
day = "1",
doi = "10.1097/00000658-198004000-00011",
language = "English (US)",
volume = "191",
pages = "456--459",
journal = "Annals of Surgery",
issn = "0003-4932",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Renal blood flow and intrarenal distribution of blood flow after decapsulation in the postischemic kidney

AU - Stothert, J. C.

PY - 1980/1/1

Y1 - 1980/1/1

N2 - Previous reports suggest the value of renal decapsulation in the prevention of renal failure after acute ischemia. It has been suggested that this response is due to a release of 'compartmental' pressure resulting in increased blood flow to the decapsulated kidney. Ten dogs were evaluated following 90 minutes of renal ischemia created by occlusion of the suprarenal aorta. Each animal underwent random unilateral decapsulation, with the contralateral kidney acting as control. Labeled 15 micron microspheres (Se85 and Ce141) were injected into the left ventricle at 15 minutes and one hour following decapsulation in six dogs. In the remaining animals the injection was carried out at 15 minutes and 48 hours. No difference in renal blood flow was found between decapsulated and control kidneys in either group. Similarly, using sectioned kidneys no difference in intrarenal distribution of blood flow was found. These data suggest that the effects caused by decapsulation are not due to hemodynamic alterations.

AB - Previous reports suggest the value of renal decapsulation in the prevention of renal failure after acute ischemia. It has been suggested that this response is due to a release of 'compartmental' pressure resulting in increased blood flow to the decapsulated kidney. Ten dogs were evaluated following 90 minutes of renal ischemia created by occlusion of the suprarenal aorta. Each animal underwent random unilateral decapsulation, with the contralateral kidney acting as control. Labeled 15 micron microspheres (Se85 and Ce141) were injected into the left ventricle at 15 minutes and one hour following decapsulation in six dogs. In the remaining animals the injection was carried out at 15 minutes and 48 hours. No difference in renal blood flow was found between decapsulated and control kidneys in either group. Similarly, using sectioned kidneys no difference in intrarenal distribution of blood flow was found. These data suggest that the effects caused by decapsulation are not due to hemodynamic alterations.

UR - http://www.scopus.com/inward/record.url?scp=0018906997&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018906997&partnerID=8YFLogxK

U2 - 10.1097/00000658-198004000-00011

DO - 10.1097/00000658-198004000-00011

M3 - Article

C2 - 7369810

AN - SCOPUS:0018906997

VL - 191

SP - 456

EP - 459

JO - Annals of Surgery

JF - Annals of Surgery

SN - 0003-4932

IS - 4

ER -