Reduction of nitro group on derivative of 1,8-napthalimide for quantitative detection of hydrogen sulfide

Angela Bamesberger, Gunwoo Kim, Jeeun Woo, Haishi Cao

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A fluorescence "turn-on" sensor (HSS) for detection of H2S was developed on the basis of NO2-NH2 reduction. HSS showed a high affinity and sensitivity to H2S over other reducing reagents, particularly for biothiols. Also, the short responding time and high linear dependence between fluorescence enhancement and H2S concentration had HSS behave as a rapid sensor for quantitatively detection of H2S in the biological level.

Original languageEnglish (US)
Pages (from-to)25-29
Number of pages5
JournalJournal of Fluorescence
Volume25
Issue number1
DOIs
StatePublished - Jan 2015

Fingerprint

Hydrogen Sulfide
Fluorescence
Derivatives
Sensors
Group
time

Keywords

  • 1 8-naphthalimide
  • HS sensor
  • Reduction

ASJC Scopus subject areas

  • Biochemistry
  • Clinical Psychology
  • Social Sciences (miscellaneous)
  • Sociology and Political Science
  • Spectroscopy
  • Clinical Biochemistry
  • Law

Cite this

Reduction of nitro group on derivative of 1,8-napthalimide for quantitative detection of hydrogen sulfide. / Bamesberger, Angela; Kim, Gunwoo; Woo, Jeeun; Cao, Haishi.

In: Journal of Fluorescence, Vol. 25, No. 1, 01.2015, p. 25-29.

Research output: Contribution to journalArticle

@article{9a3ca5b7a2844f4d877aade7156aa5b3,
title = "Reduction of nitro group on derivative of 1,8-napthalimide for quantitative detection of hydrogen sulfide",
abstract = "A fluorescence {"}turn-on{"} sensor (HSS) for detection of H2S was developed on the basis of NO2-NH2 reduction. HSS showed a high affinity and sensitivity to H2S over other reducing reagents, particularly for biothiols. Also, the short responding time and high linear dependence between fluorescence enhancement and H2S concentration had HSS behave as a rapid sensor for quantitatively detection of H2S in the biological level.",
keywords = "1 8-naphthalimide, HS sensor, Reduction",
author = "Angela Bamesberger and Gunwoo Kim and Jeeun Woo and Haishi Cao",
year = "2015",
month = "1",
doi = "10.1007/s10895-014-1494-9",
language = "English (US)",
volume = "25",
pages = "25--29",
journal = "Journal of Fluorescence",
issn = "1053-0509",
number = "1",

}

TY - JOUR

T1 - Reduction of nitro group on derivative of 1,8-napthalimide for quantitative detection of hydrogen sulfide

AU - Bamesberger, Angela

AU - Kim, Gunwoo

AU - Woo, Jeeun

AU - Cao, Haishi

PY - 2015/1

Y1 - 2015/1

N2 - A fluorescence "turn-on" sensor (HSS) for detection of H2S was developed on the basis of NO2-NH2 reduction. HSS showed a high affinity and sensitivity to H2S over other reducing reagents, particularly for biothiols. Also, the short responding time and high linear dependence between fluorescence enhancement and H2S concentration had HSS behave as a rapid sensor for quantitatively detection of H2S in the biological level.

AB - A fluorescence "turn-on" sensor (HSS) for detection of H2S was developed on the basis of NO2-NH2 reduction. HSS showed a high affinity and sensitivity to H2S over other reducing reagents, particularly for biothiols. Also, the short responding time and high linear dependence between fluorescence enhancement and H2S concentration had HSS behave as a rapid sensor for quantitatively detection of H2S in the biological level.

KW - 1 8-naphthalimide

KW - HS sensor

KW - Reduction

UR - http://www.scopus.com/inward/record.url?scp=84925461466&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84925461466&partnerID=8YFLogxK

U2 - 10.1007/s10895-014-1494-9

DO - 10.1007/s10895-014-1494-9

M3 - Article

C2 - 25501857

AN - SCOPUS:84925461466

VL - 25

SP - 25

EP - 29

JO - Journal of Fluorescence

JF - Journal of Fluorescence

SN - 1053-0509

IS - 1

ER -