Red cell damage in flexible leaflet heart valves

Yutong Liu, S. Aluri, W. Richenbacher, K. B. Chandran

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A pyrolyric carbon (rigid) bileaflet mechanical valve and an ultra high molecular weight polyethylene (UHMPE - flexible) tilting disc valves were used in the study in an in vitro pulsatile flow loop. Fresh bovine blood was used as the blood analog fluid and plasma free hemoglobin (PFHg: a measure of hemolysis) measured at 15 min. intervals, normalized to magnitude at the start of the experiment, was used as an index for blood damage. The negative pressure transients in the atrial side of the chamber were also measured. The mean and standard deviations of eight valves in each category were computed. The blood losses as well as the negative pressure transients with the flexible leaflet valve were significantly lower compared to the rigid leaflet valve. The flexibility of the leaflet, and the reduction in water hammer effect at the instant of valve closure results in reduced damage to blood cells and may be an important factor in mechanical valve design.

Original languageEnglish (US)
Title of host publicationAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
PublisherIEEE
Number of pages1
ISBN (Print)0780356756
StatePublished - Dec 1 1999
EventProceedings of the 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Fall Meeting of the Biomedical Engineering Society (1st Joint BMES / EMBS) - Atlanta, GA, USA
Duration: Oct 13 1999Oct 16 1999

Publication series

NameAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
Volume2
ISSN (Print)0589-1019

Other

OtherProceedings of the 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Fall Meeting of the Biomedical Engineering Society (1st Joint BMES / EMBS)
CityAtlanta, GA, USA
Period10/13/9910/16/99

Fingerprint

Blood
Cells
Water hammer
Pulsatile flow
Ultrahigh molecular weight polyethylenes
Hemoglobin
Hemoglobins
Carbon
Plasmas
Fluids
Experiments

ASJC Scopus subject areas

  • Signal Processing
  • Biomedical Engineering
  • Computer Vision and Pattern Recognition
  • Health Informatics

Cite this

Liu, Y., Aluri, S., Richenbacher, W., & Chandran, K. B. (1999). Red cell damage in flexible leaflet heart valves. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings; Vol. 2). IEEE.

Red cell damage in flexible leaflet heart valves. / Liu, Yutong; Aluri, S.; Richenbacher, W.; Chandran, K. B.

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. IEEE, 1999. (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings; Vol. 2).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Liu, Y, Aluri, S, Richenbacher, W & Chandran, KB 1999, Red cell damage in flexible leaflet heart valves. in Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, vol. 2, IEEE, Proceedings of the 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Fall Meeting of the Biomedical Engineering Society (1st Joint BMES / EMBS), Atlanta, GA, USA, 10/13/99.
Liu Y, Aluri S, Richenbacher W, Chandran KB. Red cell damage in flexible leaflet heart valves. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. IEEE. 1999. (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings).
Liu, Yutong ; Aluri, S. ; Richenbacher, W. ; Chandran, K. B. / Red cell damage in flexible leaflet heart valves. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. IEEE, 1999. (Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings).
@inproceedings{6fe065ca026d4ecc8725e8568e5b40be,
title = "Red cell damage in flexible leaflet heart valves",
abstract = "A pyrolyric carbon (rigid) bileaflet mechanical valve and an ultra high molecular weight polyethylene (UHMPE - flexible) tilting disc valves were used in the study in an in vitro pulsatile flow loop. Fresh bovine blood was used as the blood analog fluid and plasma free hemoglobin (PFHg: a measure of hemolysis) measured at 15 min. intervals, normalized to magnitude at the start of the experiment, was used as an index for blood damage. The negative pressure transients in the atrial side of the chamber were also measured. The mean and standard deviations of eight valves in each category were computed. The blood losses as well as the negative pressure transients with the flexible leaflet valve were significantly lower compared to the rigid leaflet valve. The flexibility of the leaflet, and the reduction in water hammer effect at the instant of valve closure results in reduced damage to blood cells and may be an important factor in mechanical valve design.",
author = "Yutong Liu and S. Aluri and W. Richenbacher and Chandran, {K. B.}",
year = "1999",
month = "12",
day = "1",
language = "English (US)",
isbn = "0780356756",
series = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",
publisher = "IEEE",
booktitle = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",

}

TY - GEN

T1 - Red cell damage in flexible leaflet heart valves

AU - Liu, Yutong

AU - Aluri, S.

AU - Richenbacher, W.

AU - Chandran, K. B.

PY - 1999/12/1

Y1 - 1999/12/1

N2 - A pyrolyric carbon (rigid) bileaflet mechanical valve and an ultra high molecular weight polyethylene (UHMPE - flexible) tilting disc valves were used in the study in an in vitro pulsatile flow loop. Fresh bovine blood was used as the blood analog fluid and plasma free hemoglobin (PFHg: a measure of hemolysis) measured at 15 min. intervals, normalized to magnitude at the start of the experiment, was used as an index for blood damage. The negative pressure transients in the atrial side of the chamber were also measured. The mean and standard deviations of eight valves in each category were computed. The blood losses as well as the negative pressure transients with the flexible leaflet valve were significantly lower compared to the rigid leaflet valve. The flexibility of the leaflet, and the reduction in water hammer effect at the instant of valve closure results in reduced damage to blood cells and may be an important factor in mechanical valve design.

AB - A pyrolyric carbon (rigid) bileaflet mechanical valve and an ultra high molecular weight polyethylene (UHMPE - flexible) tilting disc valves were used in the study in an in vitro pulsatile flow loop. Fresh bovine blood was used as the blood analog fluid and plasma free hemoglobin (PFHg: a measure of hemolysis) measured at 15 min. intervals, normalized to magnitude at the start of the experiment, was used as an index for blood damage. The negative pressure transients in the atrial side of the chamber were also measured. The mean and standard deviations of eight valves in each category were computed. The blood losses as well as the negative pressure transients with the flexible leaflet valve were significantly lower compared to the rigid leaflet valve. The flexibility of the leaflet, and the reduction in water hammer effect at the instant of valve closure results in reduced damage to blood cells and may be an important factor in mechanical valve design.

UR - http://www.scopus.com/inward/record.url?scp=0033310678&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033310678&partnerID=8YFLogxK

M3 - Conference contribution

SN - 0780356756

T3 - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

BT - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

PB - IEEE

ER -