The authors evaluated a flexible vaginal localizer contrast tampon for radiation therapy simulation. In 51 patients, the degree of cervical or vaginal cuff displacement secondary to the contrast tampon was evaluated by comparing simulation radiographs (with tampon) and initial portal radiographs (without tampon). The same comparisons were made on the radiographs obtained in 25 control subjects who underwent simulation without a tampon. Mean displacement in the group who underwent simulation with a tampon was minimal (≤5 mm in each direction) and similar to that in the control group. This technique provides reliable cervical and vaginal cuff localization.

Original languageEnglish (US)
Pages (from-to)876-881
Number of pages6
JournalRadiology
Volume211
Issue number3
DOIs
StatePublished - Jun 1999

Fingerprint

Vagina
Cervix Uteri
Radiotherapy
Radiation
Control Groups
Neoplasms
Direction compound

Keywords

  • Pelvic organs, therapeutic radiology
  • Treatment planning

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Radiation field simulation of gynecologic malignancies : Localization of the cervix and vagina with a flexible vaginal localizer contrast tampon. / Weidner, Geoffrey J.; Mayr, Nina A.; Saw, Cheng B.; Zhen, Weining; Wen, B. Chen; Hussey, David H.

In: Radiology, Vol. 211, No. 3, 06.1999, p. 876-881.

Research output: Contribution to journalArticle

Weidner, Geoffrey J. ; Mayr, Nina A. ; Saw, Cheng B. ; Zhen, Weining ; Wen, B. Chen ; Hussey, David H. / Radiation field simulation of gynecologic malignancies : Localization of the cervix and vagina with a flexible vaginal localizer contrast tampon. In: Radiology. 1999 ; Vol. 211, No. 3. pp. 876-881.
@article{f0fb8710818d4e318896e13a9950104e,
title = "Radiation field simulation of gynecologic malignancies: Localization of the cervix and vagina with a flexible vaginal localizer contrast tampon",
abstract = "The authors evaluated a flexible vaginal localizer contrast tampon for radiation therapy simulation. In 51 patients, the degree of cervical or vaginal cuff displacement secondary to the contrast tampon was evaluated by comparing simulation radiographs (with tampon) and initial portal radiographs (without tampon). The same comparisons were made on the radiographs obtained in 25 control subjects who underwent simulation without a tampon. Mean displacement in the group who underwent simulation with a tampon was minimal (≤5 mm in each direction) and similar to that in the control group. This technique provides reliable cervical and vaginal cuff localization.",
keywords = "Pelvic organs, therapeutic radiology, Treatment planning",
author = "Weidner, {Geoffrey J.} and Mayr, {Nina A.} and Saw, {Cheng B.} and Weining Zhen and Wen, {B. Chen} and Hussey, {David H.}",
year = "1999",
month = "6",
doi = "10.1148/radiology.211.3.r99jn36876",
language = "English (US)",
volume = "211",
pages = "876--881",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "3",

}

TY - JOUR

T1 - Radiation field simulation of gynecologic malignancies

T2 - Localization of the cervix and vagina with a flexible vaginal localizer contrast tampon

AU - Weidner, Geoffrey J.

AU - Mayr, Nina A.

AU - Saw, Cheng B.

AU - Zhen, Weining

AU - Wen, B. Chen

AU - Hussey, David H.

PY - 1999/6

Y1 - 1999/6

N2 - The authors evaluated a flexible vaginal localizer contrast tampon for radiation therapy simulation. In 51 patients, the degree of cervical or vaginal cuff displacement secondary to the contrast tampon was evaluated by comparing simulation radiographs (with tampon) and initial portal radiographs (without tampon). The same comparisons were made on the radiographs obtained in 25 control subjects who underwent simulation without a tampon. Mean displacement in the group who underwent simulation with a tampon was minimal (≤5 mm in each direction) and similar to that in the control group. This technique provides reliable cervical and vaginal cuff localization.

AB - The authors evaluated a flexible vaginal localizer contrast tampon for radiation therapy simulation. In 51 patients, the degree of cervical or vaginal cuff displacement secondary to the contrast tampon was evaluated by comparing simulation radiographs (with tampon) and initial portal radiographs (without tampon). The same comparisons were made on the radiographs obtained in 25 control subjects who underwent simulation without a tampon. Mean displacement in the group who underwent simulation with a tampon was minimal (≤5 mm in each direction) and similar to that in the control group. This technique provides reliable cervical and vaginal cuff localization.

KW - Pelvic organs, therapeutic radiology

KW - Treatment planning

UR - http://www.scopus.com/inward/record.url?scp=0032967007&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032967007&partnerID=8YFLogxK

U2 - 10.1148/radiology.211.3.r99jn36876

DO - 10.1148/radiology.211.3.r99jn36876

M3 - Article

C2 - 10352619

AN - SCOPUS:0032967007

VL - 211

SP - 876

EP - 881

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 3

ER -