Quantification in comprehensive two-dimensional liquid chromatography

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

This correspondence corrects the description in a recent paper by Mondello et al., "Quantification in Comprehensive Two-Dimensional Liquid Chromatography" [Mondello, L.; Herrero, M.; Kumm, T.; Dugo, P.; Cortes, H.; Dugo, G. Anal. Chem., 2008, 80, 5418-5424], of previous research on peak integration. This correspondence also shows that the peak integration method proposed in that paper is equivalent to, but is less efficient than, simply summing the data values.

Original languageEnglish (US)
Pages (from-to)5099-5101
Number of pages3
JournalAnalytical Chemistry
Volume81
Issue number12
DOIs
StatePublished - Jun 15 2009

Fingerprint

Liquid chromatography

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Quantification in comprehensive two-dimensional liquid chromatography. / Reichenbach, Stephen E.

In: Analytical Chemistry, Vol. 81, No. 12, 15.06.2009, p. 5099-5101.

Research output: Contribution to journalArticle

@article{3eedcb6af767488eaecb7cc17bbed91d,
title = "Quantification in comprehensive two-dimensional liquid chromatography",
abstract = "This correspondence corrects the description in a recent paper by Mondello et al., {"}Quantification in Comprehensive Two-Dimensional Liquid Chromatography{"} [Mondello, L.; Herrero, M.; Kumm, T.; Dugo, P.; Cortes, H.; Dugo, G. Anal. Chem., 2008, 80, 5418-5424], of previous research on peak integration. This correspondence also shows that the peak integration method proposed in that paper is equivalent to, but is less efficient than, simply summing the data values.",
author = "Reichenbach, {Stephen E}",
year = "2009",
month = "6",
day = "15",
doi = "10.1021/ac900047z",
language = "English (US)",
volume = "81",
pages = "5099--5101",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "12",

}

TY - JOUR

T1 - Quantification in comprehensive two-dimensional liquid chromatography

AU - Reichenbach, Stephen E

PY - 2009/6/15

Y1 - 2009/6/15

N2 - This correspondence corrects the description in a recent paper by Mondello et al., "Quantification in Comprehensive Two-Dimensional Liquid Chromatography" [Mondello, L.; Herrero, M.; Kumm, T.; Dugo, P.; Cortes, H.; Dugo, G. Anal. Chem., 2008, 80, 5418-5424], of previous research on peak integration. This correspondence also shows that the peak integration method proposed in that paper is equivalent to, but is less efficient than, simply summing the data values.

AB - This correspondence corrects the description in a recent paper by Mondello et al., "Quantification in Comprehensive Two-Dimensional Liquid Chromatography" [Mondello, L.; Herrero, M.; Kumm, T.; Dugo, P.; Cortes, H.; Dugo, G. Anal. Chem., 2008, 80, 5418-5424], of previous research on peak integration. This correspondence also shows that the peak integration method proposed in that paper is equivalent to, but is less efficient than, simply summing the data values.

UR - http://www.scopus.com/inward/record.url?scp=67249117438&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67249117438&partnerID=8YFLogxK

U2 - 10.1021/ac900047z

DO - 10.1021/ac900047z

M3 - Article

VL - 81

SP - 5099

EP - 5101

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 12

ER -