Proof-of-Concept Prototype for Noninvasive Intracranial Pressure Monitoring Using Ocular Hemodynamics Under Applied Force

Tyler Ketchem, Max Twedt, Darrin Lim, Greg Bashford, Jeff A. Hawks

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Studies have suggested that elevated cerebrospinal fluid (CSF) pressure can have a damaging effect on the optic nerve and visual acuity. There is need for a noninvasive CSF pressure measurement technique. A portable device for noninvasive intracranial pressure (ICP) monitoring would have a significant impact on clinical care. A proof-of-concept prototype is used to test the feasibility of a technique for monitoring ICP changes. The proposed methodology utilizes transcranial Doppler ultrasonography to monitor blood flow through the ophthalmic and central retinal arteries while forces are applied to the cornea by a controlled actuator. Control algorithms for the device were developed and tested using an integrated experimental platform. Preliminary results using tissue-mimicking materials show the ability to differentiate between materials of differing stiffness that simulates different levels of ICP. These experiments are an initial step toward a handheld noninvasive ICP monitoring device.

Original languageEnglish (US)
Pages (from-to)1-4
Number of pages4
JournalJournal of Medical Devices, Transactions of the ASME
Volume9
Issue number2
DOIs
StatePublished - Jun 1 2015

Fingerprint

Intracranial Pressure
Hemodynamics
Cerebrospinal Fluid Pressure
Monitoring
Cerebrospinal fluid
Equipment and Supplies
Retinal Artery
Doppler Transcranial Ultrasonography
Aptitude
Ultrasonography
Optic Nerve
Cornea
Visual Acuity
Pressure measurement
Optics
Blood
Actuators
Stiffness
Tissue
Experiments

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Biomedical Engineering

Cite this

Proof-of-Concept Prototype for Noninvasive Intracranial Pressure Monitoring Using Ocular Hemodynamics Under Applied Force. / Ketchem, Tyler; Twedt, Max; Lim, Darrin; Bashford, Greg; Hawks, Jeff A.

In: Journal of Medical Devices, Transactions of the ASME, Vol. 9, No. 2, 01.06.2015, p. 1-4.

Research output: Contribution to journalArticle

@article{58c8e1098e8e4b67a34965e26a35bfcc,
title = "Proof-of-Concept Prototype for Noninvasive Intracranial Pressure Monitoring Using Ocular Hemodynamics Under Applied Force",
abstract = "Studies have suggested that elevated cerebrospinal fluid (CSF) pressure can have a damaging effect on the optic nerve and visual acuity. There is need for a noninvasive CSF pressure measurement technique. A portable device for noninvasive intracranial pressure (ICP) monitoring would have a significant impact on clinical care. A proof-of-concept prototype is used to test the feasibility of a technique for monitoring ICP changes. The proposed methodology utilizes transcranial Doppler ultrasonography to monitor blood flow through the ophthalmic and central retinal arteries while forces are applied to the cornea by a controlled actuator. Control algorithms for the device were developed and tested using an integrated experimental platform. Preliminary results using tissue-mimicking materials show the ability to differentiate between materials of differing stiffness that simulates different levels of ICP. These experiments are an initial step toward a handheld noninvasive ICP monitoring device.",
author = "Tyler Ketchem and Max Twedt and Darrin Lim and Greg Bashford and Hawks, {Jeff A.}",
year = "2015",
month = "6",
day = "1",
doi = "10.1115/1.4029810",
language = "English (US)",
volume = "9",
pages = "1--4",
journal = "Journal of Medical Devices, Transactions of the ASME",
issn = "1932-6181",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "2",

}

TY - JOUR

T1 - Proof-of-Concept Prototype for Noninvasive Intracranial Pressure Monitoring Using Ocular Hemodynamics Under Applied Force

AU - Ketchem, Tyler

AU - Twedt, Max

AU - Lim, Darrin

AU - Bashford, Greg

AU - Hawks, Jeff A.

PY - 2015/6/1

Y1 - 2015/6/1

N2 - Studies have suggested that elevated cerebrospinal fluid (CSF) pressure can have a damaging effect on the optic nerve and visual acuity. There is need for a noninvasive CSF pressure measurement technique. A portable device for noninvasive intracranial pressure (ICP) monitoring would have a significant impact on clinical care. A proof-of-concept prototype is used to test the feasibility of a technique for monitoring ICP changes. The proposed methodology utilizes transcranial Doppler ultrasonography to monitor blood flow through the ophthalmic and central retinal arteries while forces are applied to the cornea by a controlled actuator. Control algorithms for the device were developed and tested using an integrated experimental platform. Preliminary results using tissue-mimicking materials show the ability to differentiate between materials of differing stiffness that simulates different levels of ICP. These experiments are an initial step toward a handheld noninvasive ICP monitoring device.

AB - Studies have suggested that elevated cerebrospinal fluid (CSF) pressure can have a damaging effect on the optic nerve and visual acuity. There is need for a noninvasive CSF pressure measurement technique. A portable device for noninvasive intracranial pressure (ICP) monitoring would have a significant impact on clinical care. A proof-of-concept prototype is used to test the feasibility of a technique for monitoring ICP changes. The proposed methodology utilizes transcranial Doppler ultrasonography to monitor blood flow through the ophthalmic and central retinal arteries while forces are applied to the cornea by a controlled actuator. Control algorithms for the device were developed and tested using an integrated experimental platform. Preliminary results using tissue-mimicking materials show the ability to differentiate between materials of differing stiffness that simulates different levels of ICP. These experiments are an initial step toward a handheld noninvasive ICP monitoring device.

UR - http://www.scopus.com/inward/record.url?scp=84929329966&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84929329966&partnerID=8YFLogxK

U2 - 10.1115/1.4029810

DO - 10.1115/1.4029810

M3 - Article

AN - SCOPUS:84929329966

VL - 9

SP - 1

EP - 4

JO - Journal of Medical Devices, Transactions of the ASME

JF - Journal of Medical Devices, Transactions of the ASME

SN - 1932-6181

IS - 2

ER -