Precast/prestressed concrete sandwich panels for thermally efficient floor/roof applications

E. Henin, G. Morcous, M. K. Tadros

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Precast concrete floor systems represent a major component of the cost and weight of precast concrete buildings. Hollow-core (HC) planking is considered the most common precast concrete floor system for residential and commercial buildings because of their economy, light weight, structural capacity, and ease of production and erection. However, the high thermal conductivity of HC planks hinders their use in radiant heated floor and roof applications where thermal insulation is needed. This paper presents the development of a precast/prestressed concrete sandwich floor panel that consists of an internal wythe of insulation and two external wythes of concrete similar to those used in sandwich wall panels. The main difference between the sandwich floor and wall panels is the design of shear connectors between concrete wythes to achieve full composite action under ultimate loads while simultaneously having an adequate creep resistance under sustained loads and acceptable deflection under live loads. Truss-shaped glass fiber-reinforced polymer ties, known as NU ties, were used as shear connectors because of their structural and thermal efficiency. The proposed floor panels have comparable weight and capacity to HC planks while being more thermally efficient and can easily be fabricated in standard casting beds with typical equipment, thus eliminating the high initial investment required for HC production. This paper presents the design, detailing, production, and testing of three 7.9-m-long (26-ft-long), 1.22-m-wide (4-ft-wide), and 200-mm-thick (8-in.-thick) specimens with 50-mm-thick (2-in.-thick) composite topping. The three specimens represent two different panel designs. One specimen has solid concrete ends and was designed for a total superimposed service load of 9.6 kPa (200 psf), whereas two specimens are fully insulated and designed for a total superimposed service load of 4.8 kPa (100 psf). The performance of the three specimens under flexure and shear loadings indicated that the proposed sandwich floor panels can achieve full composite action and have satisfactory structural performance and acceptable deflection characteristics.

Original languageEnglish (US)
Article number04014013
JournalPractice Periodical on Structural Design and Construction
Volume19
Issue number3
DOIs
StatePublished - Aug 1 2014

Fingerprint

Precast concrete
Prestressed concrete
Roofs
Concretes
Loads (forces)
Composite materials
Concrete buildings
Creep resistance
Thermal insulation
Glass fibers
Insulation
Thermal conductivity
Casting
Connector
Deflection
Plank
Testing
Polymers
Costs

Keywords

  • Composite action
  • Floor system
  • Hollow core
  • Prestressed concrete
  • Sandwich panel
  • Shear connectors
  • Thermal efficiency

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Arts and Humanities (miscellaneous)

Cite this

Precast/prestressed concrete sandwich panels for thermally efficient floor/roof applications. / Henin, E.; Morcous, G.; Tadros, M. K.

In: Practice Periodical on Structural Design and Construction, Vol. 19, No. 3, 04014013, 01.08.2014.

Research output: Contribution to journalArticle

@article{63259894cbd941e6b479b7a422016c1d,
title = "Precast/prestressed concrete sandwich panels for thermally efficient floor/roof applications",
abstract = "Precast concrete floor systems represent a major component of the cost and weight of precast concrete buildings. Hollow-core (HC) planking is considered the most common precast concrete floor system for residential and commercial buildings because of their economy, light weight, structural capacity, and ease of production and erection. However, the high thermal conductivity of HC planks hinders their use in radiant heated floor and roof applications where thermal insulation is needed. This paper presents the development of a precast/prestressed concrete sandwich floor panel that consists of an internal wythe of insulation and two external wythes of concrete similar to those used in sandwich wall panels. The main difference between the sandwich floor and wall panels is the design of shear connectors between concrete wythes to achieve full composite action under ultimate loads while simultaneously having an adequate creep resistance under sustained loads and acceptable deflection under live loads. Truss-shaped glass fiber-reinforced polymer ties, known as NU ties, were used as shear connectors because of their structural and thermal efficiency. The proposed floor panels have comparable weight and capacity to HC planks while being more thermally efficient and can easily be fabricated in standard casting beds with typical equipment, thus eliminating the high initial investment required for HC production. This paper presents the design, detailing, production, and testing of three 7.9-m-long (26-ft-long), 1.22-m-wide (4-ft-wide), and 200-mm-thick (8-in.-thick) specimens with 50-mm-thick (2-in.-thick) composite topping. The three specimens represent two different panel designs. One specimen has solid concrete ends and was designed for a total superimposed service load of 9.6 kPa (200 psf), whereas two specimens are fully insulated and designed for a total superimposed service load of 4.8 kPa (100 psf). The performance of the three specimens under flexure and shear loadings indicated that the proposed sandwich floor panels can achieve full composite action and have satisfactory structural performance and acceptable deflection characteristics.",
keywords = "Composite action, Floor system, Hollow core, Prestressed concrete, Sandwich panel, Shear connectors, Thermal efficiency",
author = "E. Henin and G. Morcous and Tadros, {M. K.}",
year = "2014",
month = "8",
day = "1",
doi = "10.1061/(ASCE)SC.1943-5576.0000213",
language = "English (US)",
volume = "19",
journal = "Practice Periodical on Structural Design and Construction",
issn = "1084-0680",
publisher = "American Society of Civil Engineers (ASCE)",
number = "3",

}

TY - JOUR

T1 - Precast/prestressed concrete sandwich panels for thermally efficient floor/roof applications

AU - Henin, E.

AU - Morcous, G.

AU - Tadros, M. K.

PY - 2014/8/1

Y1 - 2014/8/1

N2 - Precast concrete floor systems represent a major component of the cost and weight of precast concrete buildings. Hollow-core (HC) planking is considered the most common precast concrete floor system for residential and commercial buildings because of their economy, light weight, structural capacity, and ease of production and erection. However, the high thermal conductivity of HC planks hinders their use in radiant heated floor and roof applications where thermal insulation is needed. This paper presents the development of a precast/prestressed concrete sandwich floor panel that consists of an internal wythe of insulation and two external wythes of concrete similar to those used in sandwich wall panels. The main difference between the sandwich floor and wall panels is the design of shear connectors between concrete wythes to achieve full composite action under ultimate loads while simultaneously having an adequate creep resistance under sustained loads and acceptable deflection under live loads. Truss-shaped glass fiber-reinforced polymer ties, known as NU ties, were used as shear connectors because of their structural and thermal efficiency. The proposed floor panels have comparable weight and capacity to HC planks while being more thermally efficient and can easily be fabricated in standard casting beds with typical equipment, thus eliminating the high initial investment required for HC production. This paper presents the design, detailing, production, and testing of three 7.9-m-long (26-ft-long), 1.22-m-wide (4-ft-wide), and 200-mm-thick (8-in.-thick) specimens with 50-mm-thick (2-in.-thick) composite topping. The three specimens represent two different panel designs. One specimen has solid concrete ends and was designed for a total superimposed service load of 9.6 kPa (200 psf), whereas two specimens are fully insulated and designed for a total superimposed service load of 4.8 kPa (100 psf). The performance of the three specimens under flexure and shear loadings indicated that the proposed sandwich floor panels can achieve full composite action and have satisfactory structural performance and acceptable deflection characteristics.

AB - Precast concrete floor systems represent a major component of the cost and weight of precast concrete buildings. Hollow-core (HC) planking is considered the most common precast concrete floor system for residential and commercial buildings because of their economy, light weight, structural capacity, and ease of production and erection. However, the high thermal conductivity of HC planks hinders their use in radiant heated floor and roof applications where thermal insulation is needed. This paper presents the development of a precast/prestressed concrete sandwich floor panel that consists of an internal wythe of insulation and two external wythes of concrete similar to those used in sandwich wall panels. The main difference between the sandwich floor and wall panels is the design of shear connectors between concrete wythes to achieve full composite action under ultimate loads while simultaneously having an adequate creep resistance under sustained loads and acceptable deflection under live loads. Truss-shaped glass fiber-reinforced polymer ties, known as NU ties, were used as shear connectors because of their structural and thermal efficiency. The proposed floor panels have comparable weight and capacity to HC planks while being more thermally efficient and can easily be fabricated in standard casting beds with typical equipment, thus eliminating the high initial investment required for HC production. This paper presents the design, detailing, production, and testing of three 7.9-m-long (26-ft-long), 1.22-m-wide (4-ft-wide), and 200-mm-thick (8-in.-thick) specimens with 50-mm-thick (2-in.-thick) composite topping. The three specimens represent two different panel designs. One specimen has solid concrete ends and was designed for a total superimposed service load of 9.6 kPa (200 psf), whereas two specimens are fully insulated and designed for a total superimposed service load of 4.8 kPa (100 psf). The performance of the three specimens under flexure and shear loadings indicated that the proposed sandwich floor panels can achieve full composite action and have satisfactory structural performance and acceptable deflection characteristics.

KW - Composite action

KW - Floor system

KW - Hollow core

KW - Prestressed concrete

KW - Sandwich panel

KW - Shear connectors

KW - Thermal efficiency

UR - http://www.scopus.com/inward/record.url?scp=84904463671&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904463671&partnerID=8YFLogxK

U2 - 10.1061/(ASCE)SC.1943-5576.0000213

DO - 10.1061/(ASCE)SC.1943-5576.0000213

M3 - Article

AN - SCOPUS:84904463671

VL - 19

JO - Practice Periodical on Structural Design and Construction

JF - Practice Periodical on Structural Design and Construction

SN - 1084-0680

IS - 3

M1 - 04014013

ER -