Abstract

Ingestible capsule endoscope technology has been a topic of research since the middle of the 20th century and has become a prominent area of study since the commercialization of capsule endoscopy in 2000. Ingestible telemetry capsules have been investigated by NASA in the last 20 years as a means for monitoring human body temperature during periods of physical exhaustion, but are limited in sensing time due to passage through the digestive system. In this work, we present a feasibility study on a sensor that attaches to the intestinal mucosa after being delivered to the bowel via ingestible capsule to be used on long distance space flights. This study included experiments conducted on NASA's Weightless Wonder aircraft and replicated in a laboratory setting on the ground. During these experiments, a capsule was activated, manually inserted into excised porcine small intestine, and then automatically implanted a sham sensor onto the mucosal lining. The purpose of the experiment was to determine if the automated implantation sequence is affected by microgravity. Eight trials conducted in each setting yielded successful implantation of four sham sensors in microgravity and three in earth gravity. Results suggest that automated implantation is feasible in both 1G and microgravity environments though design changes are necessary to significantly improve repeatability in both environments. Though improvements in reliability of the device are needed, this experiment is a benchmark for transferring capsule technology currently used only for visual screening of the bowel to health monitoring systems for space flights.

Original languageEnglish (US)
Title of host publicationBiomedical and Biotechnology Engineering
PublisherAmerican Society of Mechanical Engineers (ASME)
ISBN (Electronic)9780791850534
DOIs
StatePublished - Jan 1 2016
EventASME 2016 International Mechanical Engineering Congress and Exposition, IMECE 2016 - Phoenix, United States
Duration: Nov 11 2016Nov 17 2016

Publication series

NameASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)
Volume3

Other

OtherASME 2016 International Mechanical Engineering Congress and Exposition, IMECE 2016
CountryUnited States
CityPhoenix
Period11/11/1611/17/16

Fingerprint

Microgravity
Biosensors
Endoscopy
Space flight
NASA
Sensors
Digestive system
Experiments
Monitoring
Telemetering
Linings
Screening
Gravitation
Earth (planet)
Aircraft
Health
Temperature

ASJC Scopus subject areas

  • Mechanical Engineering

Cite this

Slawinski, P. R., Lewis, W. M., & Terry, B. S. (2016). Performance assessment of a noninvasive swallowable biosensor deployment system in microgravity. In Biomedical and Biotechnology Engineering [2602004] (ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE); Vol. 3). American Society of Mechanical Engineers (ASME). https://doi.org/10.1115/IMECE2016-65039

Performance assessment of a noninvasive swallowable biosensor deployment system in microgravity. / Slawinski, Piotr R.; Lewis, Weston M.; Terry, Benjamin S.

Biomedical and Biotechnology Engineering. American Society of Mechanical Engineers (ASME), 2016. 2602004 (ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE); Vol. 3).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Slawinski, PR, Lewis, WM & Terry, BS 2016, Performance assessment of a noninvasive swallowable biosensor deployment system in microgravity. in Biomedical and Biotechnology Engineering., 2602004, ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE), vol. 3, American Society of Mechanical Engineers (ASME), ASME 2016 International Mechanical Engineering Congress and Exposition, IMECE 2016, Phoenix, United States, 11/11/16. https://doi.org/10.1115/IMECE2016-65039
Slawinski PR, Lewis WM, Terry BS. Performance assessment of a noninvasive swallowable biosensor deployment system in microgravity. In Biomedical and Biotechnology Engineering. American Society of Mechanical Engineers (ASME). 2016. 2602004. (ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)). https://doi.org/10.1115/IMECE2016-65039
Slawinski, Piotr R. ; Lewis, Weston M. ; Terry, Benjamin S. / Performance assessment of a noninvasive swallowable biosensor deployment system in microgravity. Biomedical and Biotechnology Engineering. American Society of Mechanical Engineers (ASME), 2016. (ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)).
@inproceedings{f8d1417483454cc6863295b75a1f2924,
title = "Performance assessment of a noninvasive swallowable biosensor deployment system in microgravity",
abstract = "Ingestible capsule endoscope technology has been a topic of research since the middle of the 20th century and has become a prominent area of study since the commercialization of capsule endoscopy in 2000. Ingestible telemetry capsules have been investigated by NASA in the last 20 years as a means for monitoring human body temperature during periods of physical exhaustion, but are limited in sensing time due to passage through the digestive system. In this work, we present a feasibility study on a sensor that attaches to the intestinal mucosa after being delivered to the bowel via ingestible capsule to be used on long distance space flights. This study included experiments conducted on NASA's Weightless Wonder aircraft and replicated in a laboratory setting on the ground. During these experiments, a capsule was activated, manually inserted into excised porcine small intestine, and then automatically implanted a sham sensor onto the mucosal lining. The purpose of the experiment was to determine if the automated implantation sequence is affected by microgravity. Eight trials conducted in each setting yielded successful implantation of four sham sensors in microgravity and three in earth gravity. Results suggest that automated implantation is feasible in both 1G and microgravity environments though design changes are necessary to significantly improve repeatability in both environments. Though improvements in reliability of the device are needed, this experiment is a benchmark for transferring capsule technology currently used only for visual screening of the bowel to health monitoring systems for space flights.",
author = "Slawinski, {Piotr R.} and Lewis, {Weston M.} and Terry, {Benjamin S.}",
year = "2016",
month = "1",
day = "1",
doi = "10.1115/IMECE2016-65039",
language = "English (US)",
series = "ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)",
publisher = "American Society of Mechanical Engineers (ASME)",
booktitle = "Biomedical and Biotechnology Engineering",

}

TY - GEN

T1 - Performance assessment of a noninvasive swallowable biosensor deployment system in microgravity

AU - Slawinski, Piotr R.

AU - Lewis, Weston M.

AU - Terry, Benjamin S.

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Ingestible capsule endoscope technology has been a topic of research since the middle of the 20th century and has become a prominent area of study since the commercialization of capsule endoscopy in 2000. Ingestible telemetry capsules have been investigated by NASA in the last 20 years as a means for monitoring human body temperature during periods of physical exhaustion, but are limited in sensing time due to passage through the digestive system. In this work, we present a feasibility study on a sensor that attaches to the intestinal mucosa after being delivered to the bowel via ingestible capsule to be used on long distance space flights. This study included experiments conducted on NASA's Weightless Wonder aircraft and replicated in a laboratory setting on the ground. During these experiments, a capsule was activated, manually inserted into excised porcine small intestine, and then automatically implanted a sham sensor onto the mucosal lining. The purpose of the experiment was to determine if the automated implantation sequence is affected by microgravity. Eight trials conducted in each setting yielded successful implantation of four sham sensors in microgravity and three in earth gravity. Results suggest that automated implantation is feasible in both 1G and microgravity environments though design changes are necessary to significantly improve repeatability in both environments. Though improvements in reliability of the device are needed, this experiment is a benchmark for transferring capsule technology currently used only for visual screening of the bowel to health monitoring systems for space flights.

AB - Ingestible capsule endoscope technology has been a topic of research since the middle of the 20th century and has become a prominent area of study since the commercialization of capsule endoscopy in 2000. Ingestible telemetry capsules have been investigated by NASA in the last 20 years as a means for monitoring human body temperature during periods of physical exhaustion, but are limited in sensing time due to passage through the digestive system. In this work, we present a feasibility study on a sensor that attaches to the intestinal mucosa after being delivered to the bowel via ingestible capsule to be used on long distance space flights. This study included experiments conducted on NASA's Weightless Wonder aircraft and replicated in a laboratory setting on the ground. During these experiments, a capsule was activated, manually inserted into excised porcine small intestine, and then automatically implanted a sham sensor onto the mucosal lining. The purpose of the experiment was to determine if the automated implantation sequence is affected by microgravity. Eight trials conducted in each setting yielded successful implantation of four sham sensors in microgravity and three in earth gravity. Results suggest that automated implantation is feasible in both 1G and microgravity environments though design changes are necessary to significantly improve repeatability in both environments. Though improvements in reliability of the device are needed, this experiment is a benchmark for transferring capsule technology currently used only for visual screening of the bowel to health monitoring systems for space flights.

UR - http://www.scopus.com/inward/record.url?scp=85021692281&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85021692281&partnerID=8YFLogxK

U2 - 10.1115/IMECE2016-65039

DO - 10.1115/IMECE2016-65039

M3 - Conference contribution

AN - SCOPUS:85021692281

T3 - ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE)

BT - Biomedical and Biotechnology Engineering

PB - American Society of Mechanical Engineers (ASME)

ER -