Paraesophageal hernias and Nissen fundoplication

Dmitry Oleynikov, Ajay Ranade, Jeremy Parcells, Nathan Bills

Research output: Chapter in Book/Report/Conference proceedingChapter

3 Citations (Scopus)

Abstract

A paraesophageal hernia is a common diagnosis with surgery as the mainstay oftreatment. A minimally invasive approach facilitates increased visualization whiledecreasing the morbidity of an open procedure. The key steps in paraesophageal herniarepair are reduction of the hernia sac, complete dissection of both crura and thegastroesophageal junction, tension free reapproximation of the hiatus, and esophageallengthening to achieve at least 3 cm of intra-abdominal esophagus. This chapter examinesthe surgical approach to paraesophageal hernias with special reference to the evolutionand practicality of using a robotic approach. Appropriate positioning and set-up as well ashaving a team experienced with use of the robot are the keystones to a successfuloperation. The robot is typically docked over the head of the bed with the trocarsseparated by 10cm to avoid robotic arm collision while keeping them superior enough tofacilitate mediastinal dissection if that becomes necessary. Improved visualization andmobility with the use of the robot can aid in the mediastinal dissection and subsequentlyprovide better esophageal lengthening.

Original languageEnglish (US)
Title of host publicationRobotic Surgery for the General Surgeon
PublisherNova Science Publishers, Inc.
Pages65-74
Number of pages10
ISBN (Print)9781629489575, 9781629489551
StatePublished - Jan 1 2014

Fingerprint

Fundoplication
Hiatal Hernia
Dissection
Robotics
Hernia
Esophagus
Morbidity

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Oleynikov, D., Ranade, A., Parcells, J., & Bills, N. (2014). Paraesophageal hernias and Nissen fundoplication. In Robotic Surgery for the General Surgeon (pp. 65-74). Nova Science Publishers, Inc..

Paraesophageal hernias and Nissen fundoplication. / Oleynikov, Dmitry; Ranade, Ajay; Parcells, Jeremy; Bills, Nathan.

Robotic Surgery for the General Surgeon. Nova Science Publishers, Inc., 2014. p. 65-74.

Research output: Chapter in Book/Report/Conference proceedingChapter

Oleynikov, D, Ranade, A, Parcells, J & Bills, N 2014, Paraesophageal hernias and Nissen fundoplication. in Robotic Surgery for the General Surgeon. Nova Science Publishers, Inc., pp. 65-74.
Oleynikov D, Ranade A, Parcells J, Bills N. Paraesophageal hernias and Nissen fundoplication. In Robotic Surgery for the General Surgeon. Nova Science Publishers, Inc. 2014. p. 65-74
Oleynikov, Dmitry ; Ranade, Ajay ; Parcells, Jeremy ; Bills, Nathan. / Paraesophageal hernias and Nissen fundoplication. Robotic Surgery for the General Surgeon. Nova Science Publishers, Inc., 2014. pp. 65-74
@inbook{2560115bf606414d9d5831193ce5a586,
title = "Paraesophageal hernias and Nissen fundoplication",
abstract = "A paraesophageal hernia is a common diagnosis with surgery as the mainstay oftreatment. A minimally invasive approach facilitates increased visualization whiledecreasing the morbidity of an open procedure. The key steps in paraesophageal herniarepair are reduction of the hernia sac, complete dissection of both crura and thegastroesophageal junction, tension free reapproximation of the hiatus, and esophageallengthening to achieve at least 3 cm of intra-abdominal esophagus. This chapter examinesthe surgical approach to paraesophageal hernias with special reference to the evolutionand practicality of using a robotic approach. Appropriate positioning and set-up as well ashaving a team experienced with use of the robot are the keystones to a successfuloperation. The robot is typically docked over the head of the bed with the trocarsseparated by 10cm to avoid robotic arm collision while keeping them superior enough tofacilitate mediastinal dissection if that becomes necessary. Improved visualization andmobility with the use of the robot can aid in the mediastinal dissection and subsequentlyprovide better esophageal lengthening.",
author = "Dmitry Oleynikov and Ajay Ranade and Jeremy Parcells and Nathan Bills",
year = "2014",
month = "1",
day = "1",
language = "English (US)",
isbn = "9781629489575",
pages = "65--74",
booktitle = "Robotic Surgery for the General Surgeon",
publisher = "Nova Science Publishers, Inc.",

}

TY - CHAP

T1 - Paraesophageal hernias and Nissen fundoplication

AU - Oleynikov, Dmitry

AU - Ranade, Ajay

AU - Parcells, Jeremy

AU - Bills, Nathan

PY - 2014/1/1

Y1 - 2014/1/1

N2 - A paraesophageal hernia is a common diagnosis with surgery as the mainstay oftreatment. A minimally invasive approach facilitates increased visualization whiledecreasing the morbidity of an open procedure. The key steps in paraesophageal herniarepair are reduction of the hernia sac, complete dissection of both crura and thegastroesophageal junction, tension free reapproximation of the hiatus, and esophageallengthening to achieve at least 3 cm of intra-abdominal esophagus. This chapter examinesthe surgical approach to paraesophageal hernias with special reference to the evolutionand practicality of using a robotic approach. Appropriate positioning and set-up as well ashaving a team experienced with use of the robot are the keystones to a successfuloperation. The robot is typically docked over the head of the bed with the trocarsseparated by 10cm to avoid robotic arm collision while keeping them superior enough tofacilitate mediastinal dissection if that becomes necessary. Improved visualization andmobility with the use of the robot can aid in the mediastinal dissection and subsequentlyprovide better esophageal lengthening.

AB - A paraesophageal hernia is a common diagnosis with surgery as the mainstay oftreatment. A minimally invasive approach facilitates increased visualization whiledecreasing the morbidity of an open procedure. The key steps in paraesophageal herniarepair are reduction of the hernia sac, complete dissection of both crura and thegastroesophageal junction, tension free reapproximation of the hiatus, and esophageallengthening to achieve at least 3 cm of intra-abdominal esophagus. This chapter examinesthe surgical approach to paraesophageal hernias with special reference to the evolutionand practicality of using a robotic approach. Appropriate positioning and set-up as well ashaving a team experienced with use of the robot are the keystones to a successfuloperation. The robot is typically docked over the head of the bed with the trocarsseparated by 10cm to avoid robotic arm collision while keeping them superior enough tofacilitate mediastinal dissection if that becomes necessary. Improved visualization andmobility with the use of the robot can aid in the mediastinal dissection and subsequentlyprovide better esophageal lengthening.

UR - http://www.scopus.com/inward/record.url?scp=84928945400&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84928945400&partnerID=8YFLogxK

M3 - Chapter

SN - 9781629489575

SN - 9781629489551

SP - 65

EP - 74

BT - Robotic Surgery for the General Surgeon

PB - Nova Science Publishers, Inc.

ER -