Biomaterial wear debris is a known contributing factor in aseptic loosening of total joint prostheses, particularly when cementless tibial trays are used in total knee arthroplasty (TKA). Local inflammatory response can lead to osteolysis and aseptic loosening of implants. The resulting lesions require careful clinical evaluation. This article presents a case of a 76-year old man with a remote history of prostate cancer and cigarette smoking who presented with acute onset left knee and tibia pain 15 years after TKA. Radiographs showed an osteolytic lesion in the distal tibial diaphysis and magnetic resonance imaging revealed a cystic lesion with evidence concerning for pathologic mid-shaft fracture. Biopsy of the lesion confirmed a foreign body reaction and revision TKA was performed. The patient was seen at 3-year follow-up without complication. The existing literature presents cases reporting osteolytic lesions of the distal femur and proximal tibial metaphysis due to polyethylene wear debris and foreign body reaction following TKA. We are unaware of case reports involving osteolysis of this etiology extending into the distal tibial diaphysis. We conclude that polyethylene wear debris with foreign body reaction should be considered in the differential diagnosis of an osteolytic lesion extending into the tibial diaphysis following TKA.
Original language | English (US) |
---|---|
Journal | Orthopedics |
Volume | 34 |
Issue number | 3 |
DOIs | |
State | Published - Mar 1 2011 |
Fingerprint
ASJC Scopus subject areas
- Orthopedics and Sports Medicine
Cite this
Osteolytic lesion of the tibial diaphysis after cementless TKA. / Vernon, Brian A.; Bollinger, Alexander J.; Garvin, Kevin Lloyd; McGarry, Sean V.
In: Orthopedics, Vol. 34, No. 3, 01.03.2011.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Osteolytic lesion of the tibial diaphysis after cementless TKA
AU - Vernon, Brian A.
AU - Bollinger, Alexander J.
AU - Garvin, Kevin Lloyd
AU - McGarry, Sean V
PY - 2011/3/1
Y1 - 2011/3/1
N2 - Biomaterial wear debris is a known contributing factor in aseptic loosening of total joint prostheses, particularly when cementless tibial trays are used in total knee arthroplasty (TKA). Local inflammatory response can lead to osteolysis and aseptic loosening of implants. The resulting lesions require careful clinical evaluation. This article presents a case of a 76-year old man with a remote history of prostate cancer and cigarette smoking who presented with acute onset left knee and tibia pain 15 years after TKA. Radiographs showed an osteolytic lesion in the distal tibial diaphysis and magnetic resonance imaging revealed a cystic lesion with evidence concerning for pathologic mid-shaft fracture. Biopsy of the lesion confirmed a foreign body reaction and revision TKA was performed. The patient was seen at 3-year follow-up without complication. The existing literature presents cases reporting osteolytic lesions of the distal femur and proximal tibial metaphysis due to polyethylene wear debris and foreign body reaction following TKA. We are unaware of case reports involving osteolysis of this etiology extending into the distal tibial diaphysis. We conclude that polyethylene wear debris with foreign body reaction should be considered in the differential diagnosis of an osteolytic lesion extending into the tibial diaphysis following TKA.
AB - Biomaterial wear debris is a known contributing factor in aseptic loosening of total joint prostheses, particularly when cementless tibial trays are used in total knee arthroplasty (TKA). Local inflammatory response can lead to osteolysis and aseptic loosening of implants. The resulting lesions require careful clinical evaluation. This article presents a case of a 76-year old man with a remote history of prostate cancer and cigarette smoking who presented with acute onset left knee and tibia pain 15 years after TKA. Radiographs showed an osteolytic lesion in the distal tibial diaphysis and magnetic resonance imaging revealed a cystic lesion with evidence concerning for pathologic mid-shaft fracture. Biopsy of the lesion confirmed a foreign body reaction and revision TKA was performed. The patient was seen at 3-year follow-up without complication. The existing literature presents cases reporting osteolytic lesions of the distal femur and proximal tibial metaphysis due to polyethylene wear debris and foreign body reaction following TKA. We are unaware of case reports involving osteolysis of this etiology extending into the distal tibial diaphysis. We conclude that polyethylene wear debris with foreign body reaction should be considered in the differential diagnosis of an osteolytic lesion extending into the tibial diaphysis following TKA.
UR - http://www.scopus.com/inward/record.url?scp=79952513199&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79952513199&partnerID=8YFLogxK
U2 - 10.3928/01477447-20110124-30
DO - 10.3928/01477447-20110124-30
M3 - Article
C2 - 21410114
AN - SCOPUS:79952513199
VL - 34
JO - Orthopedics
JF - Orthopedics
SN - 0147-7447
IS - 3
ER -