Optimizing clinical interpretation of distortion product otoacoustic emissions in infants

Chelsea M. Blankenship, Lisa L. Hunter, Douglas H. Keefe, M. Patrick Feeney, David K. Brown, Annie McCune, Denis F. Fitzpatrick, Li Lin

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Objectives: The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. Design: This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. Results: Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. Conclusions: Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F 2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.

Original languageEnglish (US)
Pages (from-to)1075-1090
Number of pages16
JournalEar and hearing
Volume39
Issue number6
DOIs
StatePublished - Jan 1 2018

Fingerprint

Hearing
Hearing Loss
Mixed Conductive-Sensorineural Hearing Loss
ROC Curve
Conductive Hearing Loss
Brain Stem Auditory Evoked Potentials
Sensorineural Hearing Loss
Signal-To-Noise Ratio
Air
Bone Conduction
Audiometry
Nurseries
Neonatal Intensive Care Units
Middle Ear
Ear
Longitudinal Studies
Reference Values
Parturition
Prospective Studies
Sensitivity and Specificity

Keywords

  • Distortion product otoacoustic emissions
  • Hearing loss
  • Infants

ASJC Scopus subject areas

  • Otorhinolaryngology
  • Speech and Hearing

Cite this

Blankenship, C. M., Hunter, L. L., Keefe, D. H., Patrick Feeney, M., Brown, D. K., McCune, A., ... Lin, L. (2018). Optimizing clinical interpretation of distortion product otoacoustic emissions in infants. Ear and hearing, 39(6), 1075-1090. https://doi.org/10.1097/AUD.0000000000000562

Optimizing clinical interpretation of distortion product otoacoustic emissions in infants. / Blankenship, Chelsea M.; Hunter, Lisa L.; Keefe, Douglas H.; Patrick Feeney, M.; Brown, David K.; McCune, Annie; Fitzpatrick, Denis F.; Lin, Li.

In: Ear and hearing, Vol. 39, No. 6, 01.01.2018, p. 1075-1090.

Research output: Contribution to journalArticle

Blankenship, CM, Hunter, LL, Keefe, DH, Patrick Feeney, M, Brown, DK, McCune, A, Fitzpatrick, DF & Lin, L 2018, 'Optimizing clinical interpretation of distortion product otoacoustic emissions in infants', Ear and hearing, vol. 39, no. 6, pp. 1075-1090. https://doi.org/10.1097/AUD.0000000000000562
Blankenship, Chelsea M. ; Hunter, Lisa L. ; Keefe, Douglas H. ; Patrick Feeney, M. ; Brown, David K. ; McCune, Annie ; Fitzpatrick, Denis F. ; Lin, Li. / Optimizing clinical interpretation of distortion product otoacoustic emissions in infants. In: Ear and hearing. 2018 ; Vol. 39, No. 6. pp. 1075-1090.
@article{af63882346a74b248b2e23788b960499,
title = "Optimizing clinical interpretation of distortion product otoacoustic emissions in infants",
abstract = "Objectives: The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. Design: This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. Results: Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. Conclusions: Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F 2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.",
keywords = "Distortion product otoacoustic emissions, Hearing loss, Infants",
author = "Blankenship, {Chelsea M.} and Hunter, {Lisa L.} and Keefe, {Douglas H.} and {Patrick Feeney}, M. and Brown, {David K.} and Annie McCune and Fitzpatrick, {Denis F.} and Li Lin",
year = "2018",
month = "1",
day = "1",
doi = "10.1097/AUD.0000000000000562",
language = "English (US)",
volume = "39",
pages = "1075--1090",
journal = "Ear and Hearing",
issn = "0196-0202",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - Optimizing clinical interpretation of distortion product otoacoustic emissions in infants

AU - Blankenship, Chelsea M.

AU - Hunter, Lisa L.

AU - Keefe, Douglas H.

AU - Patrick Feeney, M.

AU - Brown, David K.

AU - McCune, Annie

AU - Fitzpatrick, Denis F.

AU - Lin, Li

PY - 2018/1/1

Y1 - 2018/1/1

N2 - Objectives: The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. Design: This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. Results: Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. Conclusions: Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F 2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.

AB - Objectives: The purpose of this study was to analyze distortion product otoacoustic emission (DPOAE) level and signal to noise ratio in a group of infants from birth to 4 months of age to optimize prediction of hearing status. DPOAEs from infants with normal hearing (NH) and hearing loss (HL) were used to predict the presence of conductive HL (CHL), sensorineural HL (SNHL), and mixed HL (MHL). Wideband ambient absorbance was also measured and compared among the HL types. Design: This is a prospective, longitudinal study of 279 infants with verified NH and HL, including conductive, sensorineural, and mixed types that were enrolled from a well-baby nursery and two neonatal intensive care units in Cincinnati, Ohio. At approximately 1 month of age, DPOAEs (1-8 kHz), wideband absorbance (0.25-8 kHz), and air and bone conduction diagnostic tone burst auditory brainstem response (0.5-4 kHz) thresholds were measured. Hearing status was verified at approximately 9 months of age with visual reinforcement audiometry (0.5-4 kHz). Auditory brainstem response air conduction thresholds were used to assign infants to an NH or HL group, and the efficacy of DPOAE data to classify ears as NH or HL was analyzed using receiver operating characteristic (ROC) curves. Two summary statistics of the ROC curve were calculated: the area under the ROC curve and the point of symmetry on the curve at which the sensitivity and specificity were equal. DPOAE level and signal to noise ratio cutoff values were defined at each frequency as the symmetry point on their respective ROC curve, and DPOAE results were combined across frequency in a multifrequency analysis to predict the presence of HL. Results: Single-frequency test performance of DPOAEs was best at mid to high frequencies (3-8 kHz) with intermediate performance at 1.5 and 2 kHz and chance performance at 1 kHz. Infants with a conductive component to their HL (CHL and MHL combined) displayed significantly lower ambient absorbance values than the NH group. No differences in ambient absorbance were found between the NH and SNHL groups. Multifrequency analysis resulted in the best prediction of HL for the SNHL/MHL group with poorer sensitivity values when infants with CHL were included. Conclusions: Clinical interpretation of DPOAEs in infants can be improved by using age-appropriate normative ranges and optimized cutoff values. DPOAE interpretation is most predictive at higher F 2 test frequencies in young infants (2-8 kHz) due to poor test performance at 1 to 1.5 kHz. Multifrequency rules can be used to improve sensitivity while balancing specificity. Last, a sensitive middle ear measure such as wideband absorbance should be included in the test battery to assess possibility of a conductive component to the HL.

KW - Distortion product otoacoustic emissions

KW - Hearing loss

KW - Infants

UR - http://www.scopus.com/inward/record.url?scp=85053710887&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85053710887&partnerID=8YFLogxK

U2 - 10.1097/AUD.0000000000000562

DO - 10.1097/AUD.0000000000000562

M3 - Article

C2 - 29517520

AN - SCOPUS:85053710887

VL - 39

SP - 1075

EP - 1090

JO - Ear and Hearing

JF - Ear and Hearing

SN - 0196-0202

IS - 6

ER -