Abstract

We have applied nuclear resonance profiling (NRP) techniques to determine the depth distribution of implanted Al into Si. For implantation of Al at 100 keV and at doses of up to 1018 Al/cm2, our results indicate that the depth distribution of Al implanted in an ultra-high vacuum (UHV) system (∼- -8 Torr) is independent of dose rate and target orientation. For a dose of 1018 Al/cm2 a single Al distribution was observed with an Al concentration of about 65% at peak while 85% of the implanted Al was retained in the Si target. On the other hand, the depth distribution of implanted Al in a diffusion pumped vacuum (DPV) system (∼- 10-6 Torr) was greatly influenced by dose rates and target orientation. For high dose rate implantation (40-50 μA/cm2) the depth distribution of Al appears to be bimodal or broadened and about 95% of the implanted Al is retained in the Si target. A peak Al concentration of up to 75% could be obtained.

Original languageEnglish (US)
Pages (from-to)357-360
Number of pages4
JournalNuclear Inst. and Methods in Physics Research, B
Volume7-8
Issue numberPART 1
DOIs
StatePublished - Jan 1 1985

Fingerprint

Ultrahigh vacuum
Vacuum
dosage
vacuum systems
implantation
ultrahigh vacuum

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Instrumentation

Cite this

Nuclear resonance profiling of high dose implants of Al in Si. / Namavar, Fereydoon; Budnick, J. I.; Sanchez, F. H.; Otter, F. A.

In: Nuclear Inst. and Methods in Physics Research, B, Vol. 7-8, No. PART 1, 01.01.1985, p. 357-360.

Research output: Contribution to journalArticle

Namavar, Fereydoon ; Budnick, J. I. ; Sanchez, F. H. ; Otter, F. A. / Nuclear resonance profiling of high dose implants of Al in Si. In: Nuclear Inst. and Methods in Physics Research, B. 1985 ; Vol. 7-8, No. PART 1. pp. 357-360.
@article{e4f313f62ce44104af2e949344a05fc9,
title = "Nuclear resonance profiling of high dose implants of Al in Si",
abstract = "We have applied nuclear resonance profiling (NRP) techniques to determine the depth distribution of implanted Al into Si. For implantation of Al at 100 keV and at doses of up to 1018 Al/cm2, our results indicate that the depth distribution of Al implanted in an ultra-high vacuum (UHV) system (∼- -8 Torr) is independent of dose rate and target orientation. For a dose of 1018 Al/cm2 a single Al distribution was observed with an Al concentration of about 65{\%} at peak while 85{\%} of the implanted Al was retained in the Si target. On the other hand, the depth distribution of implanted Al in a diffusion pumped vacuum (DPV) system (∼- 10-6 Torr) was greatly influenced by dose rates and target orientation. For high dose rate implantation (40-50 μA/cm2) the depth distribution of Al appears to be bimodal or broadened and about 95{\%} of the implanted Al is retained in the Si target. A peak Al concentration of up to 75{\%} could be obtained.",
author = "Fereydoon Namavar and Budnick, {J. I.} and Sanchez, {F. H.} and Otter, {F. A.}",
year = "1985",
month = "1",
day = "1",
doi = "10.1016/0168-583X(85)90581-6",
language = "English (US)",
volume = "7-8",
pages = "357--360",
journal = "Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms",
issn = "0168-583X",
publisher = "Elsevier",
number = "PART 1",

}

TY - JOUR

T1 - Nuclear resonance profiling of high dose implants of Al in Si

AU - Namavar, Fereydoon

AU - Budnick, J. I.

AU - Sanchez, F. H.

AU - Otter, F. A.

PY - 1985/1/1

Y1 - 1985/1/1

N2 - We have applied nuclear resonance profiling (NRP) techniques to determine the depth distribution of implanted Al into Si. For implantation of Al at 100 keV and at doses of up to 1018 Al/cm2, our results indicate that the depth distribution of Al implanted in an ultra-high vacuum (UHV) system (∼- -8 Torr) is independent of dose rate and target orientation. For a dose of 1018 Al/cm2 a single Al distribution was observed with an Al concentration of about 65% at peak while 85% of the implanted Al was retained in the Si target. On the other hand, the depth distribution of implanted Al in a diffusion pumped vacuum (DPV) system (∼- 10-6 Torr) was greatly influenced by dose rates and target orientation. For high dose rate implantation (40-50 μA/cm2) the depth distribution of Al appears to be bimodal or broadened and about 95% of the implanted Al is retained in the Si target. A peak Al concentration of up to 75% could be obtained.

AB - We have applied nuclear resonance profiling (NRP) techniques to determine the depth distribution of implanted Al into Si. For implantation of Al at 100 keV and at doses of up to 1018 Al/cm2, our results indicate that the depth distribution of Al implanted in an ultra-high vacuum (UHV) system (∼- -8 Torr) is independent of dose rate and target orientation. For a dose of 1018 Al/cm2 a single Al distribution was observed with an Al concentration of about 65% at peak while 85% of the implanted Al was retained in the Si target. On the other hand, the depth distribution of implanted Al in a diffusion pumped vacuum (DPV) system (∼- 10-6 Torr) was greatly influenced by dose rates and target orientation. For high dose rate implantation (40-50 μA/cm2) the depth distribution of Al appears to be bimodal or broadened and about 95% of the implanted Al is retained in the Si target. A peak Al concentration of up to 75% could be obtained.

UR - http://www.scopus.com/inward/record.url?scp=0022025734&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022025734&partnerID=8YFLogxK

U2 - 10.1016/0168-583X(85)90581-6

DO - 10.1016/0168-583X(85)90581-6

M3 - Article

VL - 7-8

SP - 357

EP - 360

JO - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

JF - Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms

SN - 0168-583X

IS - PART 1

ER -