NMR Imaging with shorted coaxial line probes

Kenneth A. Rubinson, Michael D Boska

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

At frequencies below 1 GHz, resonant sections of coaxial lines have long been used in CW-Electron Paramagnetic Resonance (EPR) with the sample placed at the position of maximum B 1 at a short circuited end. Here, we show that because of the excellent separation of the B and E fields, the shield of the line can be removed in the region of the truncated end without greatly perturbing the RF properties of the line. The open region of the shield provides an aperture for local imaging in MRI. The B 1 fields can be shaped by contouring the inner conductor and outer shield, and the image aperture is controlled by the shape of the shield cutout. The shield opening can range from a narrow longitudinal slit up to a full 360° section that has only a few conducting strips of the shield remaining. Imaging with probes having shield diameters from 2 mm to 10 cm have been demonstrated. For imaging the useful depth is limited to approximately three to four times the probe's outer radius. Alternately, a relatively sharp cutoff at only a mm depth can be obtained by controlling the region of the shield removed, the RF power applied, and the probe diameter. The probes described here can be resonant or nonresonant. Because of the inherent broad bandwidth of the nonresonant truncated line probes, they have the potential for use in FT-EPR and FT-EPR imaging as well as other applications that require minimizing dead times.

Original languageEnglish (US)
Pages (from-to)291-299
Number of pages9
JournalMagnetic Resonance Imaging
Volume13
Issue number2
DOIs
StatePublished - Jan 1 1995

Fingerprint

Electron Spin Resonance Spectroscopy
Magnetic Resonance Imaging
Paramagnetic resonance
Imaging techniques
Magnetic resonance imaging
Bandwidth

Keywords

  • B field
  • Broadband sample irradiation
  • NMR imaging
  • NMR probe

ASJC Scopus subject areas

  • Biophysics
  • Biomedical Engineering
  • Radiology Nuclear Medicine and imaging

Cite this

NMR Imaging with shorted coaxial line probes. / Rubinson, Kenneth A.; Boska, Michael D.

In: Magnetic Resonance Imaging, Vol. 13, No. 2, 01.01.1995, p. 291-299.

Research output: Contribution to journalArticle

Rubinson, Kenneth A. ; Boska, Michael D. / NMR Imaging with shorted coaxial line probes. In: Magnetic Resonance Imaging. 1995 ; Vol. 13, No. 2. pp. 291-299.
@article{cf71e8fccc944b8e9e778fb457704c77,
title = "NMR Imaging with shorted coaxial line probes",
abstract = "At frequencies below 1 GHz, resonant sections of coaxial lines have long been used in CW-Electron Paramagnetic Resonance (EPR) with the sample placed at the position of maximum B 1 at a short circuited end. Here, we show that because of the excellent separation of the B and E fields, the shield of the line can be removed in the region of the truncated end without greatly perturbing the RF properties of the line. The open region of the shield provides an aperture for local imaging in MRI. The B 1 fields can be shaped by contouring the inner conductor and outer shield, and the image aperture is controlled by the shape of the shield cutout. The shield opening can range from a narrow longitudinal slit up to a full 360° section that has only a few conducting strips of the shield remaining. Imaging with probes having shield diameters from 2 mm to 10 cm have been demonstrated. For imaging the useful depth is limited to approximately three to four times the probe's outer radius. Alternately, a relatively sharp cutoff at only a mm depth can be obtained by controlling the region of the shield removed, the RF power applied, and the probe diameter. The probes described here can be resonant or nonresonant. Because of the inherent broad bandwidth of the nonresonant truncated line probes, they have the potential for use in FT-EPR and FT-EPR imaging as well as other applications that require minimizing dead times.",
keywords = "B field, Broadband sample irradiation, NMR imaging, NMR probe",
author = "Rubinson, {Kenneth A.} and Boska, {Michael D}",
year = "1995",
month = "1",
day = "1",
doi = "10.1016/0730-725X(94)00097-M",
language = "English (US)",
volume = "13",
pages = "291--299",
journal = "Magnetic Resonance Imaging",
issn = "0730-725X",
publisher = "Elsevier Inc.",
number = "2",

}

TY - JOUR

T1 - NMR Imaging with shorted coaxial line probes

AU - Rubinson, Kenneth A.

AU - Boska, Michael D

PY - 1995/1/1

Y1 - 1995/1/1

N2 - At frequencies below 1 GHz, resonant sections of coaxial lines have long been used in CW-Electron Paramagnetic Resonance (EPR) with the sample placed at the position of maximum B 1 at a short circuited end. Here, we show that because of the excellent separation of the B and E fields, the shield of the line can be removed in the region of the truncated end without greatly perturbing the RF properties of the line. The open region of the shield provides an aperture for local imaging in MRI. The B 1 fields can be shaped by contouring the inner conductor and outer shield, and the image aperture is controlled by the shape of the shield cutout. The shield opening can range from a narrow longitudinal slit up to a full 360° section that has only a few conducting strips of the shield remaining. Imaging with probes having shield diameters from 2 mm to 10 cm have been demonstrated. For imaging the useful depth is limited to approximately three to four times the probe's outer radius. Alternately, a relatively sharp cutoff at only a mm depth can be obtained by controlling the region of the shield removed, the RF power applied, and the probe diameter. The probes described here can be resonant or nonresonant. Because of the inherent broad bandwidth of the nonresonant truncated line probes, they have the potential for use in FT-EPR and FT-EPR imaging as well as other applications that require minimizing dead times.

AB - At frequencies below 1 GHz, resonant sections of coaxial lines have long been used in CW-Electron Paramagnetic Resonance (EPR) with the sample placed at the position of maximum B 1 at a short circuited end. Here, we show that because of the excellent separation of the B and E fields, the shield of the line can be removed in the region of the truncated end without greatly perturbing the RF properties of the line. The open region of the shield provides an aperture for local imaging in MRI. The B 1 fields can be shaped by contouring the inner conductor and outer shield, and the image aperture is controlled by the shape of the shield cutout. The shield opening can range from a narrow longitudinal slit up to a full 360° section that has only a few conducting strips of the shield remaining. Imaging with probes having shield diameters from 2 mm to 10 cm have been demonstrated. For imaging the useful depth is limited to approximately three to four times the probe's outer radius. Alternately, a relatively sharp cutoff at only a mm depth can be obtained by controlling the region of the shield removed, the RF power applied, and the probe diameter. The probes described here can be resonant or nonresonant. Because of the inherent broad bandwidth of the nonresonant truncated line probes, they have the potential for use in FT-EPR and FT-EPR imaging as well as other applications that require minimizing dead times.

KW - B field

KW - Broadband sample irradiation

KW - NMR imaging

KW - NMR probe

UR - http://www.scopus.com/inward/record.url?scp=0028930187&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028930187&partnerID=8YFLogxK

U2 - 10.1016/0730-725X(94)00097-M

DO - 10.1016/0730-725X(94)00097-M

M3 - Article

VL - 13

SP - 291

EP - 299

JO - Magnetic Resonance Imaging

JF - Magnetic Resonance Imaging

SN - 0730-725X

IS - 2

ER -