Multielemental self-absorption reduction in laser-induced breakdown spectroscopy by using microwave-assisted excitation

Yun Tang, Jiaming Li, Zhongqi Hao, Shisong Tang, Zhihao Zhu, Lianbo Guo, Xiangyou Li, Xiaoyan Zeng, Jun Duan, Yongfeng Lu

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

The self-absorption effect seriously affects the accuracy of determination in laser-induced breakdown spectroscopy (LIBS). In this work, we proposed to reduce multielemental self-absorption within a wide spectral range (200-900 nm) by using microwave-assisted excitation in LIBS (MAE-LIBS). Self-absorption reduction of sodium (Na), potassium (K), aluminum (Al), silicon (Si), and calcium (Ca) in potassium feldspar using MAE-LIBS was investigated. The mechanisms of self-absorption reduction in MAE-LIBS were also investigated. The results show that the serious self-absorption of spectral lines (Na and K) was reduced. The full widths at half maximum (FWHMs) of Na I 589.0 nm, Na I 589.6 nm, K I 766.5 nm, and K I 769.9 nm in potassium feldspar were reduced by 43%, 43%, 53%, and 47%, respectively. MAE-LIBS also has a little FWHM reduction for spectral lines with weak self-absorption. The results demonstrate that MAE-LIBS can simultaneously reduce multielemental self-absorption.

Original languageEnglish (US)
Pages (from-to)12121-12130
Number of pages10
JournalOptics Express
Volume26
Issue number9
DOIs
StatePublished - Apr 30 2018

Fingerprint

laser-induced breakdown spectroscopy
self absorption
microwaves
excitation
potassium
line spectra
calcium
sodium
aluminum
silicon

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics

Cite this

Multielemental self-absorption reduction in laser-induced breakdown spectroscopy by using microwave-assisted excitation. / Tang, Yun; Li, Jiaming; Hao, Zhongqi; Tang, Shisong; Zhu, Zhihao; Guo, Lianbo; Li, Xiangyou; Zeng, Xiaoyan; Duan, Jun; Lu, Yongfeng.

In: Optics Express, Vol. 26, No. 9, 30.04.2018, p. 12121-12130.

Research output: Contribution to journalArticle

Tang, Y, Li, J, Hao, Z, Tang, S, Zhu, Z, Guo, L, Li, X, Zeng, X, Duan, J & Lu, Y 2018, 'Multielemental self-absorption reduction in laser-induced breakdown spectroscopy by using microwave-assisted excitation', Optics Express, vol. 26, no. 9, pp. 12121-12130. https://doi.org/10.1364/OE.26.012121
Tang, Yun ; Li, Jiaming ; Hao, Zhongqi ; Tang, Shisong ; Zhu, Zhihao ; Guo, Lianbo ; Li, Xiangyou ; Zeng, Xiaoyan ; Duan, Jun ; Lu, Yongfeng. / Multielemental self-absorption reduction in laser-induced breakdown spectroscopy by using microwave-assisted excitation. In: Optics Express. 2018 ; Vol. 26, No. 9. pp. 12121-12130.
@article{2868ec369f5548999641e6ab502d3844,
title = "Multielemental self-absorption reduction in laser-induced breakdown spectroscopy by using microwave-assisted excitation",
abstract = "The self-absorption effect seriously affects the accuracy of determination in laser-induced breakdown spectroscopy (LIBS). In this work, we proposed to reduce multielemental self-absorption within a wide spectral range (200-900 nm) by using microwave-assisted excitation in LIBS (MAE-LIBS). Self-absorption reduction of sodium (Na), potassium (K), aluminum (Al), silicon (Si), and calcium (Ca) in potassium feldspar using MAE-LIBS was investigated. The mechanisms of self-absorption reduction in MAE-LIBS were also investigated. The results show that the serious self-absorption of spectral lines (Na and K) was reduced. The full widths at half maximum (FWHMs) of Na I 589.0 nm, Na I 589.6 nm, K I 766.5 nm, and K I 769.9 nm in potassium feldspar were reduced by 43{\%}, 43{\%}, 53{\%}, and 47{\%}, respectively. MAE-LIBS also has a little FWHM reduction for spectral lines with weak self-absorption. The results demonstrate that MAE-LIBS can simultaneously reduce multielemental self-absorption.",
author = "Yun Tang and Jiaming Li and Zhongqi Hao and Shisong Tang and Zhihao Zhu and Lianbo Guo and Xiangyou Li and Xiaoyan Zeng and Jun Duan and Yongfeng Lu",
year = "2018",
month = "4",
day = "30",
doi = "10.1364/OE.26.012121",
language = "English (US)",
volume = "26",
pages = "12121--12130",
journal = "Optics Express",
issn = "1094-4087",
publisher = "The Optical Society",
number = "9",

}

TY - JOUR

T1 - Multielemental self-absorption reduction in laser-induced breakdown spectroscopy by using microwave-assisted excitation

AU - Tang, Yun

AU - Li, Jiaming

AU - Hao, Zhongqi

AU - Tang, Shisong

AU - Zhu, Zhihao

AU - Guo, Lianbo

AU - Li, Xiangyou

AU - Zeng, Xiaoyan

AU - Duan, Jun

AU - Lu, Yongfeng

PY - 2018/4/30

Y1 - 2018/4/30

N2 - The self-absorption effect seriously affects the accuracy of determination in laser-induced breakdown spectroscopy (LIBS). In this work, we proposed to reduce multielemental self-absorption within a wide spectral range (200-900 nm) by using microwave-assisted excitation in LIBS (MAE-LIBS). Self-absorption reduction of sodium (Na), potassium (K), aluminum (Al), silicon (Si), and calcium (Ca) in potassium feldspar using MAE-LIBS was investigated. The mechanisms of self-absorption reduction in MAE-LIBS were also investigated. The results show that the serious self-absorption of spectral lines (Na and K) was reduced. The full widths at half maximum (FWHMs) of Na I 589.0 nm, Na I 589.6 nm, K I 766.5 nm, and K I 769.9 nm in potassium feldspar were reduced by 43%, 43%, 53%, and 47%, respectively. MAE-LIBS also has a little FWHM reduction for spectral lines with weak self-absorption. The results demonstrate that MAE-LIBS can simultaneously reduce multielemental self-absorption.

AB - The self-absorption effect seriously affects the accuracy of determination in laser-induced breakdown spectroscopy (LIBS). In this work, we proposed to reduce multielemental self-absorption within a wide spectral range (200-900 nm) by using microwave-assisted excitation in LIBS (MAE-LIBS). Self-absorption reduction of sodium (Na), potassium (K), aluminum (Al), silicon (Si), and calcium (Ca) in potassium feldspar using MAE-LIBS was investigated. The mechanisms of self-absorption reduction in MAE-LIBS were also investigated. The results show that the serious self-absorption of spectral lines (Na and K) was reduced. The full widths at half maximum (FWHMs) of Na I 589.0 nm, Na I 589.6 nm, K I 766.5 nm, and K I 769.9 nm in potassium feldspar were reduced by 43%, 43%, 53%, and 47%, respectively. MAE-LIBS also has a little FWHM reduction for spectral lines with weak self-absorption. The results demonstrate that MAE-LIBS can simultaneously reduce multielemental self-absorption.

UR - http://www.scopus.com/inward/record.url?scp=85046370240&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85046370240&partnerID=8YFLogxK

U2 - 10.1364/OE.26.012121

DO - 10.1364/OE.26.012121

M3 - Article

AN - SCOPUS:85046370240

VL - 26

SP - 12121

EP - 12130

JO - Optics Express

JF - Optics Express

SN - 1094-4087

IS - 9