Modified elliptical machine motor-drive design for assistive gait rehabilitation

Carl A. Nelson, Judith M. Burnfield, Yu Shu, Thad W. Buster, Adam P. Taylor, Andrew Graham

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Current gait rehabilitation systems have limited use in community and home settings due to issues of design, cost, and demands on clinical staff. To overcome these challenges, a new gait rehabilitation machine was designed and developed by modifying an existing elliptical trainer. The Intelligently Controlled Assistive Rehabilitation Elliptical (ICARE) provides answers to design limitations that occur in partial-bodyweight-support treadmill systems and other robotic systems by providing a simulated gait motion without the financial and human resource challenges. The ICARE system integrates ergonomic, comfort and safety enhancements with a motor-drive system to optimize usability by individuals with physical disabilities in hospitals, homes, and fitness settings. The affordable new design provides a complete system that reduces physical demands on clinical staff without compromising patient safety. Development and preliminary testing of the ICARE's motor-drive system are detailed.

Original languageEnglish (US)
Article number021001
JournalJournal of Medical Devices, Transactions of the ASME
Volume5
Issue number2
DOIs
StatePublished - May 2 2011

Fingerprint

Gait
Patient rehabilitation
Rehabilitation
Exercise equipment
Human Engineering
Robotics
Patient Safety
Ergonomics
Personnel
Safety
Costs and Cost Analysis
Drive
Testing
Costs

Keywords

  • Assistive elliptical machine
  • Gait rehabilitation

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Biomedical Engineering

Cite this

Modified elliptical machine motor-drive design for assistive gait rehabilitation. / Nelson, Carl A.; Burnfield, Judith M.; Shu, Yu; Buster, Thad W.; Taylor, Adam P.; Graham, Andrew.

In: Journal of Medical Devices, Transactions of the ASME, Vol. 5, No. 2, 021001, 02.05.2011.

Research output: Contribution to journalArticle

@article{c36d909531504de39f1086edc98a4c33,
title = "Modified elliptical machine motor-drive design for assistive gait rehabilitation",
abstract = "Current gait rehabilitation systems have limited use in community and home settings due to issues of design, cost, and demands on clinical staff. To overcome these challenges, a new gait rehabilitation machine was designed and developed by modifying an existing elliptical trainer. The Intelligently Controlled Assistive Rehabilitation Elliptical (ICARE) provides answers to design limitations that occur in partial-bodyweight-support treadmill systems and other robotic systems by providing a simulated gait motion without the financial and human resource challenges. The ICARE system integrates ergonomic, comfort and safety enhancements with a motor-drive system to optimize usability by individuals with physical disabilities in hospitals, homes, and fitness settings. The affordable new design provides a complete system that reduces physical demands on clinical staff without compromising patient safety. Development and preliminary testing of the ICARE's motor-drive system are detailed.",
keywords = "Assistive elliptical machine, Gait rehabilitation",
author = "Nelson, {Carl A.} and Burnfield, {Judith M.} and Yu Shu and Buster, {Thad W.} and Taylor, {Adam P.} and Andrew Graham",
year = "2011",
month = "5",
day = "2",
doi = "10.1115/1.4003693",
language = "English (US)",
volume = "5",
journal = "Journal of Medical Devices, Transactions of the ASME",
issn = "1932-6181",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "2",

}

TY - JOUR

T1 - Modified elliptical machine motor-drive design for assistive gait rehabilitation

AU - Nelson, Carl A.

AU - Burnfield, Judith M.

AU - Shu, Yu

AU - Buster, Thad W.

AU - Taylor, Adam P.

AU - Graham, Andrew

PY - 2011/5/2

Y1 - 2011/5/2

N2 - Current gait rehabilitation systems have limited use in community and home settings due to issues of design, cost, and demands on clinical staff. To overcome these challenges, a new gait rehabilitation machine was designed and developed by modifying an existing elliptical trainer. The Intelligently Controlled Assistive Rehabilitation Elliptical (ICARE) provides answers to design limitations that occur in partial-bodyweight-support treadmill systems and other robotic systems by providing a simulated gait motion without the financial and human resource challenges. The ICARE system integrates ergonomic, comfort and safety enhancements with a motor-drive system to optimize usability by individuals with physical disabilities in hospitals, homes, and fitness settings. The affordable new design provides a complete system that reduces physical demands on clinical staff without compromising patient safety. Development and preliminary testing of the ICARE's motor-drive system are detailed.

AB - Current gait rehabilitation systems have limited use in community and home settings due to issues of design, cost, and demands on clinical staff. To overcome these challenges, a new gait rehabilitation machine was designed and developed by modifying an existing elliptical trainer. The Intelligently Controlled Assistive Rehabilitation Elliptical (ICARE) provides answers to design limitations that occur in partial-bodyweight-support treadmill systems and other robotic systems by providing a simulated gait motion without the financial and human resource challenges. The ICARE system integrates ergonomic, comfort and safety enhancements with a motor-drive system to optimize usability by individuals with physical disabilities in hospitals, homes, and fitness settings. The affordable new design provides a complete system that reduces physical demands on clinical staff without compromising patient safety. Development and preliminary testing of the ICARE's motor-drive system are detailed.

KW - Assistive elliptical machine

KW - Gait rehabilitation

UR - http://www.scopus.com/inward/record.url?scp=79955530277&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79955530277&partnerID=8YFLogxK

U2 - 10.1115/1.4003693

DO - 10.1115/1.4003693

M3 - Article

AN - SCOPUS:79955530277

VL - 5

JO - Journal of Medical Devices, Transactions of the ASME

JF - Journal of Medical Devices, Transactions of the ASME

SN - 1932-6181

IS - 2

M1 - 021001

ER -