Model relating EMG signals to elbow torque during rapid loaded movement

Jeffrey C Woldstad, Don B. Chaffin, Gary D. Langolf

Research output: Contribution to journalConference article

Abstract

A biomechanical model of the elbow was developed to predicted torque values present during rapid flexion and extension movements of the forearm under high inertial loads. The model uses as input multiple surface electromyographs (EMG's) collected over the biceps brachii and triceps brachii muscles and various kinematic variables. Model components include a geometric model of the elbow, a fundamental dynamic force-EMG function, a muscle length compensation function and a speed-of-shortening compensation function. Validation results are reported in terms of goodness-of-fit between predicted and measured torque values collected for three different subjects completing rapid inertially loaded movements to a specified target. Slight deviation of the predicted values from the measured torque value at low exertion levels were noted and are attributed to passive elastic elements not present in the model. In general, the validation results indicate that the elbow torque values accompanying rapid flexion and extension of the elbow can be accurately modelled as a function of measured surface EMG's.

Original languageEnglish (US)
Number of pages1
JournalJournal of Biomechanics
Volume22
Issue number10
DOIs
StatePublished - Jan 1 1989
EventAbstracts of the XII Congress, International Society of Biomechanics - Los Angeles, CA, USA
Duration: Jun 26 1989Jun 30 1989

Fingerprint

Torque
Elbow
Muscle
Muscles
Biomechanical Phenomena
Forearm
Kinematics
Compensation and Redress

ASJC Scopus subject areas

  • Biophysics
  • Orthopedics and Sports Medicine
  • Biomedical Engineering
  • Rehabilitation

Cite this

Model relating EMG signals to elbow torque during rapid loaded movement. / Woldstad, Jeffrey C; Chaffin, Don B.; Langolf, Gary D.

In: Journal of Biomechanics, Vol. 22, No. 10, 01.01.1989.

Research output: Contribution to journalConference article

Woldstad, Jeffrey C ; Chaffin, Don B. ; Langolf, Gary D. / Model relating EMG signals to elbow torque during rapid loaded movement. In: Journal of Biomechanics. 1989 ; Vol. 22, No. 10.
@article{df5d851a6c6d40028e158fba304cc71f,
title = "Model relating EMG signals to elbow torque during rapid loaded movement",
abstract = "A biomechanical model of the elbow was developed to predicted torque values present during rapid flexion and extension movements of the forearm under high inertial loads. The model uses as input multiple surface electromyographs (EMG's) collected over the biceps brachii and triceps brachii muscles and various kinematic variables. Model components include a geometric model of the elbow, a fundamental dynamic force-EMG function, a muscle length compensation function and a speed-of-shortening compensation function. Validation results are reported in terms of goodness-of-fit between predicted and measured torque values collected for three different subjects completing rapid inertially loaded movements to a specified target. Slight deviation of the predicted values from the measured torque value at low exertion levels were noted and are attributed to passive elastic elements not present in the model. In general, the validation results indicate that the elbow torque values accompanying rapid flexion and extension of the elbow can be accurately modelled as a function of measured surface EMG's.",
author = "Woldstad, {Jeffrey C} and Chaffin, {Don B.} and Langolf, {Gary D.}",
year = "1989",
month = "1",
day = "1",
doi = "10.1016/0021-9290(89)90516-2",
language = "English (US)",
volume = "22",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "10",

}

TY - JOUR

T1 - Model relating EMG signals to elbow torque during rapid loaded movement

AU - Woldstad, Jeffrey C

AU - Chaffin, Don B.

AU - Langolf, Gary D.

PY - 1989/1/1

Y1 - 1989/1/1

N2 - A biomechanical model of the elbow was developed to predicted torque values present during rapid flexion and extension movements of the forearm under high inertial loads. The model uses as input multiple surface electromyographs (EMG's) collected over the biceps brachii and triceps brachii muscles and various kinematic variables. Model components include a geometric model of the elbow, a fundamental dynamic force-EMG function, a muscle length compensation function and a speed-of-shortening compensation function. Validation results are reported in terms of goodness-of-fit between predicted and measured torque values collected for three different subjects completing rapid inertially loaded movements to a specified target. Slight deviation of the predicted values from the measured torque value at low exertion levels were noted and are attributed to passive elastic elements not present in the model. In general, the validation results indicate that the elbow torque values accompanying rapid flexion and extension of the elbow can be accurately modelled as a function of measured surface EMG's.

AB - A biomechanical model of the elbow was developed to predicted torque values present during rapid flexion and extension movements of the forearm under high inertial loads. The model uses as input multiple surface electromyographs (EMG's) collected over the biceps brachii and triceps brachii muscles and various kinematic variables. Model components include a geometric model of the elbow, a fundamental dynamic force-EMG function, a muscle length compensation function and a speed-of-shortening compensation function. Validation results are reported in terms of goodness-of-fit between predicted and measured torque values collected for three different subjects completing rapid inertially loaded movements to a specified target. Slight deviation of the predicted values from the measured torque value at low exertion levels were noted and are attributed to passive elastic elements not present in the model. In general, the validation results indicate that the elbow torque values accompanying rapid flexion and extension of the elbow can be accurately modelled as a function of measured surface EMG's.

UR - http://www.scopus.com/inward/record.url?scp=0024946503&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024946503&partnerID=8YFLogxK

U2 - 10.1016/0021-9290(89)90516-2

DO - 10.1016/0021-9290(89)90516-2

M3 - Conference article

VL - 22

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 10

ER -