Microbubble responses to a similar mechanical index with different real-time perfusion imaging techniques

Thomas Richard Porter, Joseph Oberdorfer, Patrick Rafter, John Lof, Feng Xie

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

The purpose of this study was to determine differences in contrast enhancement and microbubble destruction rates with current commercially available low-mechanical index (MI) real-time perfusion imaging modalities. A tissue-mimicking phantom was developed that had vessels at 3 cm (near field) and 9 cm (far field) from a real-time transducer. Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) were injected proximal to a mixing chamber, and then passed through these vessels while the region was insonified with either pulses of alternating polarity with pulse inversion Doppler (PID) or pulses of alternating amplitude by power modulation (PM) at MIs of 0.1, 0.2 and 0.3. Effluent microbubble concentration, contrast intensity and the slope of digital contrast intensity vs. time were measured. Our results demonstrated that microbubble destruction already occurs with PID at an MI of 0.1. Contrast intensity seen with PID was less than with PM. Therefore, differences in contrast enhancement and microbubble destruction rates occur at a similar MI setting when using different real-time pulse sequence schemes.

Original languageEnglish (US)
Pages (from-to)1187-1192
Number of pages6
JournalUltrasound in Medicine and Biology
Volume29
Issue number8
DOIs
StatePublished - Aug 1 2003

Fingerprint

Microbubbles
Perfusion Imaging
imaging techniques
pulses
destruction
inversions
vessels
Fluorocarbons
modulation
Transducers
augmentation
effluents
Albumins
albumins
far fields
near fields
polarity
transducers
Glucose
chambers

Keywords

  • Mechanical index
  • Microbubbles
  • Pulse sequence schemes
  • Ultrasound

ASJC Scopus subject areas

  • Biophysics
  • Radiological and Ultrasound Technology
  • Acoustics and Ultrasonics

Cite this

Microbubble responses to a similar mechanical index with different real-time perfusion imaging techniques. / Porter, Thomas Richard; Oberdorfer, Joseph; Rafter, Patrick; Lof, John; Xie, Feng.

In: Ultrasound in Medicine and Biology, Vol. 29, No. 8, 01.08.2003, p. 1187-1192.

Research output: Contribution to journalArticle

@article{2144fe5fd1d04eb396efb89ca4a1b1e8,
title = "Microbubble responses to a similar mechanical index with different real-time perfusion imaging techniques",
abstract = "The purpose of this study was to determine differences in contrast enhancement and microbubble destruction rates with current commercially available low-mechanical index (MI) real-time perfusion imaging modalities. A tissue-mimicking phantom was developed that had vessels at 3 cm (near field) and 9 cm (far field) from a real-time transducer. Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) were injected proximal to a mixing chamber, and then passed through these vessels while the region was insonified with either pulses of alternating polarity with pulse inversion Doppler (PID) or pulses of alternating amplitude by power modulation (PM) at MIs of 0.1, 0.2 and 0.3. Effluent microbubble concentration, contrast intensity and the slope of digital contrast intensity vs. time were measured. Our results demonstrated that microbubble destruction already occurs with PID at an MI of 0.1. Contrast intensity seen with PID was less than with PM. Therefore, differences in contrast enhancement and microbubble destruction rates occur at a similar MI setting when using different real-time pulse sequence schemes.",
keywords = "Mechanical index, Microbubbles, Pulse sequence schemes, Ultrasound",
author = "Porter, {Thomas Richard} and Joseph Oberdorfer and Patrick Rafter and John Lof and Feng Xie",
year = "2003",
month = "8",
day = "1",
doi = "10.1016/S0301-5629(03)00900-1",
language = "English (US)",
volume = "29",
pages = "1187--1192",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier USA",
number = "8",

}

TY - JOUR

T1 - Microbubble responses to a similar mechanical index with different real-time perfusion imaging techniques

AU - Porter, Thomas Richard

AU - Oberdorfer, Joseph

AU - Rafter, Patrick

AU - Lof, John

AU - Xie, Feng

PY - 2003/8/1

Y1 - 2003/8/1

N2 - The purpose of this study was to determine differences in contrast enhancement and microbubble destruction rates with current commercially available low-mechanical index (MI) real-time perfusion imaging modalities. A tissue-mimicking phantom was developed that had vessels at 3 cm (near field) and 9 cm (far field) from a real-time transducer. Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) were injected proximal to a mixing chamber, and then passed through these vessels while the region was insonified with either pulses of alternating polarity with pulse inversion Doppler (PID) or pulses of alternating amplitude by power modulation (PM) at MIs of 0.1, 0.2 and 0.3. Effluent microbubble concentration, contrast intensity and the slope of digital contrast intensity vs. time were measured. Our results demonstrated that microbubble destruction already occurs with PID at an MI of 0.1. Contrast intensity seen with PID was less than with PM. Therefore, differences in contrast enhancement and microbubble destruction rates occur at a similar MI setting when using different real-time pulse sequence schemes.

AB - The purpose of this study was to determine differences in contrast enhancement and microbubble destruction rates with current commercially available low-mechanical index (MI) real-time perfusion imaging modalities. A tissue-mimicking phantom was developed that had vessels at 3 cm (near field) and 9 cm (far field) from a real-time transducer. Perfluorocarbon-exposed sonicated dextrose albumin microbubbles (PESDA) were injected proximal to a mixing chamber, and then passed through these vessels while the region was insonified with either pulses of alternating polarity with pulse inversion Doppler (PID) or pulses of alternating amplitude by power modulation (PM) at MIs of 0.1, 0.2 and 0.3. Effluent microbubble concentration, contrast intensity and the slope of digital contrast intensity vs. time were measured. Our results demonstrated that microbubble destruction already occurs with PID at an MI of 0.1. Contrast intensity seen with PID was less than with PM. Therefore, differences in contrast enhancement and microbubble destruction rates occur at a similar MI setting when using different real-time pulse sequence schemes.

KW - Mechanical index

KW - Microbubbles

KW - Pulse sequence schemes

KW - Ultrasound

UR - http://www.scopus.com/inward/record.url?scp=0041932395&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0041932395&partnerID=8YFLogxK

U2 - 10.1016/S0301-5629(03)00900-1

DO - 10.1016/S0301-5629(03)00900-1

M3 - Article

C2 - 12946521

AN - SCOPUS:0041932395

VL - 29

SP - 1187

EP - 1192

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 8

ER -