Micro-computed tomography for the quantitative 3-dimensional assessment of the compact myocardium in the mouse embryo

Samer S. Merchant, Yasuhiro Kosaka, H. Joseph Yost, Edward W. Hsu, Luca Brunelli

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Background: Ventricular non-compaction is characterized by a thin layer of compact ventricular myocardium and it is an important abnormality in the mouse heart. It is reminiscent of left ventricular non-compaction, a fairly common human congenital cardiomyopathy. Non-compaction in transgenic mice has been classically evaluated by measuring the thickness of the compact myocardium through histological techniques involving image analysis of 2-dimensional (D) sections. Given the 3D nature of the heart, the aim of this study was to determine whether a technique for the non-destructive, 3D assessment of the mouse embryonic compact myocardium could be developed. Methods and Results: Micro-computed tomography (micro-CT), in combination with iodine staining, enabled the differentiation of the trabecular from the compact myocardium in wild-type mice. The 3D and digital nature of the micro-CT data allowed computation anatomical techniques to be readily applied, which were demonstrated via construction of group atlases and atlas-based descriptive statistics. Finally, micro-CT was used to identify the presence of non-compaction in mice with a deletion of the cell cycle inhibitor protein, p27 Kip1. Conclusions: Iodine staining-enhanced micro-CT with computational anatomical analysis represents a valid addition to classical histology for the delineation of compact myocardial wall thickness in the mouse embryo. Given the quantitative 3D resolution of micro-CT, these approaches might provide helpful information for the analysis of non compaction.

Original languageEnglish (US)
Pages (from-to)1795-1803
Number of pages9
JournalCirculation Journal
Volume80
Issue number8
DOIs
StatePublished - Jan 1 2016

Fingerprint

Myocardium
Embryonic Structures
Tomography
Atlases
Iodine
Staining and Labeling
Histological Techniques
Cell Cycle Proteins
Cardiomyopathies
Transgenic Mice
Histology

Keywords

  • 3D-Cardiac morphology
  • Micro-computed tomography
  • P27
  • Transgenic mouse
  • Ventricular noncompaction

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Micro-computed tomography for the quantitative 3-dimensional assessment of the compact myocardium in the mouse embryo. / Merchant, Samer S.; Kosaka, Yasuhiro; Yost, H. Joseph; Hsu, Edward W.; Brunelli, Luca.

In: Circulation Journal, Vol. 80, No. 8, 01.01.2016, p. 1795-1803.

Research output: Contribution to journalArticle

Merchant, Samer S. ; Kosaka, Yasuhiro ; Yost, H. Joseph ; Hsu, Edward W. ; Brunelli, Luca. / Micro-computed tomography for the quantitative 3-dimensional assessment of the compact myocardium in the mouse embryo. In: Circulation Journal. 2016 ; Vol. 80, No. 8. pp. 1795-1803.
@article{f881a91ee9274a84b54a89d9598dd404,
title = "Micro-computed tomography for the quantitative 3-dimensional assessment of the compact myocardium in the mouse embryo",
abstract = "Background: Ventricular non-compaction is characterized by a thin layer of compact ventricular myocardium and it is an important abnormality in the mouse heart. It is reminiscent of left ventricular non-compaction, a fairly common human congenital cardiomyopathy. Non-compaction in transgenic mice has been classically evaluated by measuring the thickness of the compact myocardium through histological techniques involving image analysis of 2-dimensional (D) sections. Given the 3D nature of the heart, the aim of this study was to determine whether a technique for the non-destructive, 3D assessment of the mouse embryonic compact myocardium could be developed. Methods and Results: Micro-computed tomography (micro-CT), in combination with iodine staining, enabled the differentiation of the trabecular from the compact myocardium in wild-type mice. The 3D and digital nature of the micro-CT data allowed computation anatomical techniques to be readily applied, which were demonstrated via construction of group atlases and atlas-based descriptive statistics. Finally, micro-CT was used to identify the presence of non-compaction in mice with a deletion of the cell cycle inhibitor protein, p27 Kip1. Conclusions: Iodine staining-enhanced micro-CT with computational anatomical analysis represents a valid addition to classical histology for the delineation of compact myocardial wall thickness in the mouse embryo. Given the quantitative 3D resolution of micro-CT, these approaches might provide helpful information for the analysis of non compaction.",
keywords = "3D-Cardiac morphology, Micro-computed tomography, P27, Transgenic mouse, Ventricular noncompaction",
author = "Merchant, {Samer S.} and Yasuhiro Kosaka and Yost, {H. Joseph} and Hsu, {Edward W.} and Luca Brunelli",
year = "2016",
month = "1",
day = "1",
doi = "10.1253/circj.CJ-16-0180",
language = "English (US)",
volume = "80",
pages = "1795--1803",
journal = "Circulation Journal",
issn = "1346-9843",
publisher = "Japanese Circulation Society",
number = "8",

}

TY - JOUR

T1 - Micro-computed tomography for the quantitative 3-dimensional assessment of the compact myocardium in the mouse embryo

AU - Merchant, Samer S.

AU - Kosaka, Yasuhiro

AU - Yost, H. Joseph

AU - Hsu, Edward W.

AU - Brunelli, Luca

PY - 2016/1/1

Y1 - 2016/1/1

N2 - Background: Ventricular non-compaction is characterized by a thin layer of compact ventricular myocardium and it is an important abnormality in the mouse heart. It is reminiscent of left ventricular non-compaction, a fairly common human congenital cardiomyopathy. Non-compaction in transgenic mice has been classically evaluated by measuring the thickness of the compact myocardium through histological techniques involving image analysis of 2-dimensional (D) sections. Given the 3D nature of the heart, the aim of this study was to determine whether a technique for the non-destructive, 3D assessment of the mouse embryonic compact myocardium could be developed. Methods and Results: Micro-computed tomography (micro-CT), in combination with iodine staining, enabled the differentiation of the trabecular from the compact myocardium in wild-type mice. The 3D and digital nature of the micro-CT data allowed computation anatomical techniques to be readily applied, which were demonstrated via construction of group atlases and atlas-based descriptive statistics. Finally, micro-CT was used to identify the presence of non-compaction in mice with a deletion of the cell cycle inhibitor protein, p27 Kip1. Conclusions: Iodine staining-enhanced micro-CT with computational anatomical analysis represents a valid addition to classical histology for the delineation of compact myocardial wall thickness in the mouse embryo. Given the quantitative 3D resolution of micro-CT, these approaches might provide helpful information for the analysis of non compaction.

AB - Background: Ventricular non-compaction is characterized by a thin layer of compact ventricular myocardium and it is an important abnormality in the mouse heart. It is reminiscent of left ventricular non-compaction, a fairly common human congenital cardiomyopathy. Non-compaction in transgenic mice has been classically evaluated by measuring the thickness of the compact myocardium through histological techniques involving image analysis of 2-dimensional (D) sections. Given the 3D nature of the heart, the aim of this study was to determine whether a technique for the non-destructive, 3D assessment of the mouse embryonic compact myocardium could be developed. Methods and Results: Micro-computed tomography (micro-CT), in combination with iodine staining, enabled the differentiation of the trabecular from the compact myocardium in wild-type mice. The 3D and digital nature of the micro-CT data allowed computation anatomical techniques to be readily applied, which were demonstrated via construction of group atlases and atlas-based descriptive statistics. Finally, micro-CT was used to identify the presence of non-compaction in mice with a deletion of the cell cycle inhibitor protein, p27 Kip1. Conclusions: Iodine staining-enhanced micro-CT with computational anatomical analysis represents a valid addition to classical histology for the delineation of compact myocardial wall thickness in the mouse embryo. Given the quantitative 3D resolution of micro-CT, these approaches might provide helpful information for the analysis of non compaction.

KW - 3D-Cardiac morphology

KW - Micro-computed tomography

KW - P27

KW - Transgenic mouse

KW - Ventricular noncompaction

UR - http://www.scopus.com/inward/record.url?scp=84982286570&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84982286570&partnerID=8YFLogxK

U2 - 10.1253/circj.CJ-16-0180

DO - 10.1253/circj.CJ-16-0180

M3 - Article

VL - 80

SP - 1795

EP - 1803

JO - Circulation Journal

JF - Circulation Journal

SN - 1346-9843

IS - 8

ER -