Magnesium and pH imaging of the human brain at 3.0 Tesla

Peter B. Barker, Edward J. Butterworth, Michael D Boska, Jay Nelson, K. M.A. Welch

Research output: Contribution to journalArticle

40 Citations (Scopus)

Abstract

Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calculated from the SI data. By using the equations of Golding and Golding (Magn. Reson. Med. 1995;33: 467-474), average [Mg2+] for all brain regions studied was 0.42 ± 0.05 mM, whereas average brain pH was found to be 7.07 ± 0.03, with no significant regional variations. Phosphorus metabolite concentrations (relative to ATP, assumed to be 3.0 mM/kg wet weight) were 5.39 ± 1.88, 1.30 ± 0.39, 5.97 ± 3.17, and 4.33 ± 1.45 mM/kg wet weight for phosphomonoesters, inorganic phosphate, phosphodiesters, and phosphocreatine (PCr), respectively. These values are in good general agreement with those reported previously. Typical signal-to- noise ratios of 15:1 were obtained for PCr in spectra from nominal 31.5 cc voxel sizes with a 34-min scan time. Limits on spatial resolution and the likely error of the magnesium and pH values are discussed.

Original languageEnglish (US)
Pages (from-to)400-406
Number of pages7
JournalMagnetic Resonance in Medicine
Volume41
Issue number2
DOIs
StatePublished - Mar 9 1999

Fingerprint

Phosphocreatine
Neuroimaging
Magnesium
Phosphorus
Adenosine Triphosphate
Phosphates
Weights and Measures
Brain
Signal-To-Noise Ratio
Healthy Volunteers
Magnetic Resonance Spectroscopy

Keywords

  • 31-phosphorus
  • Magnesium
  • Spatial resolution
  • Spectroscopic imaging
  • pH

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Magnesium and pH imaging of the human brain at 3.0 Tesla. / Barker, Peter B.; Butterworth, Edward J.; Boska, Michael D; Nelson, Jay; Welch, K. M.A.

In: Magnetic Resonance in Medicine, Vol. 41, No. 2, 09.03.1999, p. 400-406.

Research output: Contribution to journalArticle

Barker, Peter B. ; Butterworth, Edward J. ; Boska, Michael D ; Nelson, Jay ; Welch, K. M.A. / Magnesium and pH imaging of the human brain at 3.0 Tesla. In: Magnetic Resonance in Medicine. 1999 ; Vol. 41, No. 2. pp. 400-406.
@article{aace65015b684c9a82890350190a558b,
title = "Magnesium and pH imaging of the human brain at 3.0 Tesla",
abstract = "Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calculated from the SI data. By using the equations of Golding and Golding (Magn. Reson. Med. 1995;33: 467-474), average [Mg2+] for all brain regions studied was 0.42 ± 0.05 mM, whereas average brain pH was found to be 7.07 ± 0.03, with no significant regional variations. Phosphorus metabolite concentrations (relative to ATP, assumed to be 3.0 mM/kg wet weight) were 5.39 ± 1.88, 1.30 ± 0.39, 5.97 ± 3.17, and 4.33 ± 1.45 mM/kg wet weight for phosphomonoesters, inorganic phosphate, phosphodiesters, and phosphocreatine (PCr), respectively. These values are in good general agreement with those reported previously. Typical signal-to- noise ratios of 15:1 were obtained for PCr in spectra from nominal 31.5 cc voxel sizes with a 34-min scan time. Limits on spatial resolution and the likely error of the magnesium and pH values are discussed.",
keywords = "31-phosphorus, Magnesium, Spatial resolution, Spectroscopic imaging, pH",
author = "Barker, {Peter B.} and Butterworth, {Edward J.} and Boska, {Michael D} and Jay Nelson and Welch, {K. M.A.}",
year = "1999",
month = "3",
day = "9",
doi = "10.1002/(SICI)1522-2594(199902)41:2<400::AID-MRM26>3.0.CO;2-E",
language = "English (US)",
volume = "41",
pages = "400--406",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Magnesium and pH imaging of the human brain at 3.0 Tesla

AU - Barker, Peter B.

AU - Butterworth, Edward J.

AU - Boska, Michael D

AU - Nelson, Jay

AU - Welch, K. M.A.

PY - 1999/3/9

Y1 - 1999/3/9

N2 - Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calculated from the SI data. By using the equations of Golding and Golding (Magn. Reson. Med. 1995;33: 467-474), average [Mg2+] for all brain regions studied was 0.42 ± 0.05 mM, whereas average brain pH was found to be 7.07 ± 0.03, with no significant regional variations. Phosphorus metabolite concentrations (relative to ATP, assumed to be 3.0 mM/kg wet weight) were 5.39 ± 1.88, 1.30 ± 0.39, 5.97 ± 3.17, and 4.33 ± 1.45 mM/kg wet weight for phosphomonoesters, inorganic phosphate, phosphodiesters, and phosphocreatine (PCr), respectively. These values are in good general agreement with those reported previously. Typical signal-to- noise ratios of 15:1 were obtained for PCr in spectra from nominal 31.5 cc voxel sizes with a 34-min scan time. Limits on spatial resolution and the likely error of the magnesium and pH values are discussed.

AB - Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calculated from the SI data. By using the equations of Golding and Golding (Magn. Reson. Med. 1995;33: 467-474), average [Mg2+] for all brain regions studied was 0.42 ± 0.05 mM, whereas average brain pH was found to be 7.07 ± 0.03, with no significant regional variations. Phosphorus metabolite concentrations (relative to ATP, assumed to be 3.0 mM/kg wet weight) were 5.39 ± 1.88, 1.30 ± 0.39, 5.97 ± 3.17, and 4.33 ± 1.45 mM/kg wet weight for phosphomonoesters, inorganic phosphate, phosphodiesters, and phosphocreatine (PCr), respectively. These values are in good general agreement with those reported previously. Typical signal-to- noise ratios of 15:1 were obtained for PCr in spectra from nominal 31.5 cc voxel sizes with a 34-min scan time. Limits on spatial resolution and the likely error of the magnesium and pH values are discussed.

KW - 31-phosphorus

KW - Magnesium

KW - Spatial resolution

KW - Spectroscopic imaging

KW - pH

UR - http://www.scopus.com/inward/record.url?scp=0032966735&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032966735&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1522-2594(199902)41:2<400::AID-MRM26>3.0.CO;2-E

DO - 10.1002/(SICI)1522-2594(199902)41:2<400::AID-MRM26>3.0.CO;2-E

M3 - Article

VL - 41

SP - 400

EP - 406

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -