The nonuniform fields required by intensity-modulation radiation therapy (IMRT) can be delivered using conventional multileaf collimators (MLC) as beam modulators. In MLC-based IMRT, the nonuniform field is initially converted into an intensity map represented as a matrix of beam intensities. The intensity map is then decomposed into a series of subfields or segments of uniform intensities. Although there are many ways of segmenting the beam intensity matrix, a resulting subfield is only deliverable if it satisfies the constraints imposed by the MLC. These constraints exist as a result of the design of the MLC. The simplest constraint of the MLC is that its pairs of leaves can only move in and out in one dimension. Additional constraints include collision of opposing leaves and the need to match the tongue-and-groove to reduce interleaf leakage. The practical aspect of MLC-based IMRT requires that an optimized algorithm decomposes the nonuniform field into the least number of segments and therefore reduces the delivery time. This paper examines the static use and the dynamic use of MLCs to perform MLC-based IMRT.

Original languageEnglish (US)
Pages (from-to)199-204
Number of pages6
JournalMedical Dosimetry
Volume26
Issue number2
DOIs
StatePublished - Jan 1 2001

Fingerprint

sequencing
leaves
radiation therapy
collimators
Radiotherapy
modulation
Tongue
tongue
matrices
grooves
modulators
delivery
leakage
collisions

Keywords

  • IMRT
  • Intensity modulation
  • Leaf sequencing
  • MLC

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Cite this

Leaf sequencing techniques for Mlc-Based IMRT. / Saw, C. B.; Siochi, R. A C; Ayyangar, K. M.; Zhen, Weining; Enke, Charles Arthur.

In: Medical Dosimetry, Vol. 26, No. 2, 01.01.2001, p. 199-204.

Research output: Contribution to journalArticle

Saw, C. B. ; Siochi, R. A C ; Ayyangar, K. M. ; Zhen, Weining ; Enke, Charles Arthur. / Leaf sequencing techniques for Mlc-Based IMRT. In: Medical Dosimetry. 2001 ; Vol. 26, No. 2. pp. 199-204.
@article{3be03a21479e4d359ee440b6b270da7b,
title = "Leaf sequencing techniques for Mlc-Based IMRT",
abstract = "The nonuniform fields required by intensity-modulation radiation therapy (IMRT) can be delivered using conventional multileaf collimators (MLC) as beam modulators. In MLC-based IMRT, the nonuniform field is initially converted into an intensity map represented as a matrix of beam intensities. The intensity map is then decomposed into a series of subfields or segments of uniform intensities. Although there are many ways of segmenting the beam intensity matrix, a resulting subfield is only deliverable if it satisfies the constraints imposed by the MLC. These constraints exist as a result of the design of the MLC. The simplest constraint of the MLC is that its pairs of leaves can only move in and out in one dimension. Additional constraints include collision of opposing leaves and the need to match the tongue-and-groove to reduce interleaf leakage. The practical aspect of MLC-based IMRT requires that an optimized algorithm decomposes the nonuniform field into the least number of segments and therefore reduces the delivery time. This paper examines the static use and the dynamic use of MLCs to perform MLC-based IMRT.",
keywords = "IMRT, Intensity modulation, Leaf sequencing, MLC",
author = "Saw, {C. B.} and Siochi, {R. A C} and Ayyangar, {K. M.} and Weining Zhen and Enke, {Charles Arthur}",
year = "2001",
month = "1",
day = "1",
doi = "10.1016/S0958-3947(01)00064-4",
language = "English (US)",
volume = "26",
pages = "199--204",
journal = "Medical Dosimetry",
issn = "0958-3947",
publisher = "Elsevier Inc.",
number = "2",

}

TY - JOUR

T1 - Leaf sequencing techniques for Mlc-Based IMRT

AU - Saw, C. B.

AU - Siochi, R. A C

AU - Ayyangar, K. M.

AU - Zhen, Weining

AU - Enke, Charles Arthur

PY - 2001/1/1

Y1 - 2001/1/1

N2 - The nonuniform fields required by intensity-modulation radiation therapy (IMRT) can be delivered using conventional multileaf collimators (MLC) as beam modulators. In MLC-based IMRT, the nonuniform field is initially converted into an intensity map represented as a matrix of beam intensities. The intensity map is then decomposed into a series of subfields or segments of uniform intensities. Although there are many ways of segmenting the beam intensity matrix, a resulting subfield is only deliverable if it satisfies the constraints imposed by the MLC. These constraints exist as a result of the design of the MLC. The simplest constraint of the MLC is that its pairs of leaves can only move in and out in one dimension. Additional constraints include collision of opposing leaves and the need to match the tongue-and-groove to reduce interleaf leakage. The practical aspect of MLC-based IMRT requires that an optimized algorithm decomposes the nonuniform field into the least number of segments and therefore reduces the delivery time. This paper examines the static use and the dynamic use of MLCs to perform MLC-based IMRT.

AB - The nonuniform fields required by intensity-modulation radiation therapy (IMRT) can be delivered using conventional multileaf collimators (MLC) as beam modulators. In MLC-based IMRT, the nonuniform field is initially converted into an intensity map represented as a matrix of beam intensities. The intensity map is then decomposed into a series of subfields or segments of uniform intensities. Although there are many ways of segmenting the beam intensity matrix, a resulting subfield is only deliverable if it satisfies the constraints imposed by the MLC. These constraints exist as a result of the design of the MLC. The simplest constraint of the MLC is that its pairs of leaves can only move in and out in one dimension. Additional constraints include collision of opposing leaves and the need to match the tongue-and-groove to reduce interleaf leakage. The practical aspect of MLC-based IMRT requires that an optimized algorithm decomposes the nonuniform field into the least number of segments and therefore reduces the delivery time. This paper examines the static use and the dynamic use of MLCs to perform MLC-based IMRT.

KW - IMRT

KW - Intensity modulation

KW - Leaf sequencing

KW - MLC

UR - http://www.scopus.com/inward/record.url?scp=0035001176&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035001176&partnerID=8YFLogxK

U2 - 10.1016/S0958-3947(01)00064-4

DO - 10.1016/S0958-3947(01)00064-4

M3 - Article

C2 - 11444522

AN - SCOPUS:0035001176

VL - 26

SP - 199

EP - 204

JO - Medical Dosimetry

JF - Medical Dosimetry

SN - 0958-3947

IS - 2

ER -