Incorporation of extra amino acids in peptide recognition probe to improve specificity and selectivity of an electrochemical peptide-based sensor

Anita J. Zaitouna, Alex J. Maben, Rebecca Y. Lai

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

We investigated the effect of incorporating extra amino acids (AA) at the n-terminus of the thiolated and methylene blue-modified peptide probe on both specificity and selectivity of an electrochemical peptide-based (E-PB) HIV sensor. The addition of a flexible (SG)3 hexapeptide is, in particular, useful in improving sensor selectivity, whereas the addition of a highly hydrophilic (EK)3 hexapeptide has shown to be effective in enhancing sensor specificity. Overall, both E-PB sensors fabricated using peptide probes with the added AA (SG-EAA and EK-EAA) showed better specificity and selectivity, especially when compared to the sensor fabricated using a peptide probe without the extra AA (EAA). For example, the selectivity factor recorded in the 50% saliva was ~2.5 for the EAA sensor, whereas the selectivity factor was 7.8 for both the SG-EAA and EK-EAA sensors. Other sensor properties such as the limit of detection and dynamic range were minimally affected by the addition of the six AA sequence. The limit of detection was 0.5 nM for the EAA sensor and 1 nM for both SG-EAA and EK-EAA sensors. The saturation target concentration was ~200 nM for all three sensors. Unlike previously reported E-PB HIV sensors, the peptide probe functions as both the recognition element and antifouling passivating agent; this modification eliminates the need to include an additional antifouling diluent, which simplifies the sensor design and fabrication protocol.

Original languageEnglish (US)
Pages (from-to)157-164
Number of pages8
JournalAnalytica Chimica Acta
Volume886
DOIs
StatePublished - Jul 30 2015

Fingerprint

peptide
amino acid
probe
sensor
Amino Acids
Peptides
Sensors
Limit of Detection
HIV
Methylene Blue
human immunodeficiency virus
incorporation
Saliva
Amino Acid Sequence
antifouling agent
saliva
antifouling
Chemical elements
saturation
Fabrication

Keywords

  • Alternating current voltammetry
  • Antifouling agents
  • Cyclic voltammetry
  • Electrochemical peptide-based sensors
  • Human immunodeficiency virus antibodies
  • Methylene blue

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Environmental Chemistry
  • Spectroscopy

Cite this

Incorporation of extra amino acids in peptide recognition probe to improve specificity and selectivity of an electrochemical peptide-based sensor. / Zaitouna, Anita J.; Maben, Alex J.; Lai, Rebecca Y.

In: Analytica Chimica Acta, Vol. 886, 30.07.2015, p. 157-164.

Research output: Contribution to journalArticle

@article{33f45219638642ebbb1a3affbce946d7,
title = "Incorporation of extra amino acids in peptide recognition probe to improve specificity and selectivity of an electrochemical peptide-based sensor",
abstract = "We investigated the effect of incorporating extra amino acids (AA) at the n-terminus of the thiolated and methylene blue-modified peptide probe on both specificity and selectivity of an electrochemical peptide-based (E-PB) HIV sensor. The addition of a flexible (SG)3 hexapeptide is, in particular, useful in improving sensor selectivity, whereas the addition of a highly hydrophilic (EK)3 hexapeptide has shown to be effective in enhancing sensor specificity. Overall, both E-PB sensors fabricated using peptide probes with the added AA (SG-EAA and EK-EAA) showed better specificity and selectivity, especially when compared to the sensor fabricated using a peptide probe without the extra AA (EAA). For example, the selectivity factor recorded in the 50{\%} saliva was ~2.5 for the EAA sensor, whereas the selectivity factor was 7.8 for both the SG-EAA and EK-EAA sensors. Other sensor properties such as the limit of detection and dynamic range were minimally affected by the addition of the six AA sequence. The limit of detection was 0.5 nM for the EAA sensor and 1 nM for both SG-EAA and EK-EAA sensors. The saturation target concentration was ~200 nM for all three sensors. Unlike previously reported E-PB HIV sensors, the peptide probe functions as both the recognition element and antifouling passivating agent; this modification eliminates the need to include an additional antifouling diluent, which simplifies the sensor design and fabrication protocol.",
keywords = "Alternating current voltammetry, Antifouling agents, Cyclic voltammetry, Electrochemical peptide-based sensors, Human immunodeficiency virus antibodies, Methylene blue",
author = "Zaitouna, {Anita J.} and Maben, {Alex J.} and Lai, {Rebecca Y.}",
year = "2015",
month = "7",
day = "30",
doi = "10.1016/j.aca.2015.05.037",
language = "English (US)",
volume = "886",
pages = "157--164",
journal = "Analytica Chimica Acta",
issn = "0003-2670",
publisher = "Elsevier",

}

TY - JOUR

T1 - Incorporation of extra amino acids in peptide recognition probe to improve specificity and selectivity of an electrochemical peptide-based sensor

AU - Zaitouna, Anita J.

AU - Maben, Alex J.

AU - Lai, Rebecca Y.

PY - 2015/7/30

Y1 - 2015/7/30

N2 - We investigated the effect of incorporating extra amino acids (AA) at the n-terminus of the thiolated and methylene blue-modified peptide probe on both specificity and selectivity of an electrochemical peptide-based (E-PB) HIV sensor. The addition of a flexible (SG)3 hexapeptide is, in particular, useful in improving sensor selectivity, whereas the addition of a highly hydrophilic (EK)3 hexapeptide has shown to be effective in enhancing sensor specificity. Overall, both E-PB sensors fabricated using peptide probes with the added AA (SG-EAA and EK-EAA) showed better specificity and selectivity, especially when compared to the sensor fabricated using a peptide probe without the extra AA (EAA). For example, the selectivity factor recorded in the 50% saliva was ~2.5 for the EAA sensor, whereas the selectivity factor was 7.8 for both the SG-EAA and EK-EAA sensors. Other sensor properties such as the limit of detection and dynamic range were minimally affected by the addition of the six AA sequence. The limit of detection was 0.5 nM for the EAA sensor and 1 nM for both SG-EAA and EK-EAA sensors. The saturation target concentration was ~200 nM for all three sensors. Unlike previously reported E-PB HIV sensors, the peptide probe functions as both the recognition element and antifouling passivating agent; this modification eliminates the need to include an additional antifouling diluent, which simplifies the sensor design and fabrication protocol.

AB - We investigated the effect of incorporating extra amino acids (AA) at the n-terminus of the thiolated and methylene blue-modified peptide probe on both specificity and selectivity of an electrochemical peptide-based (E-PB) HIV sensor. The addition of a flexible (SG)3 hexapeptide is, in particular, useful in improving sensor selectivity, whereas the addition of a highly hydrophilic (EK)3 hexapeptide has shown to be effective in enhancing sensor specificity. Overall, both E-PB sensors fabricated using peptide probes with the added AA (SG-EAA and EK-EAA) showed better specificity and selectivity, especially when compared to the sensor fabricated using a peptide probe without the extra AA (EAA). For example, the selectivity factor recorded in the 50% saliva was ~2.5 for the EAA sensor, whereas the selectivity factor was 7.8 for both the SG-EAA and EK-EAA sensors. Other sensor properties such as the limit of detection and dynamic range were minimally affected by the addition of the six AA sequence. The limit of detection was 0.5 nM for the EAA sensor and 1 nM for both SG-EAA and EK-EAA sensors. The saturation target concentration was ~200 nM for all three sensors. Unlike previously reported E-PB HIV sensors, the peptide probe functions as both the recognition element and antifouling passivating agent; this modification eliminates the need to include an additional antifouling diluent, which simplifies the sensor design and fabrication protocol.

KW - Alternating current voltammetry

KW - Antifouling agents

KW - Cyclic voltammetry

KW - Electrochemical peptide-based sensors

KW - Human immunodeficiency virus antibodies

KW - Methylene blue

UR - http://www.scopus.com/inward/record.url?scp=84940448990&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84940448990&partnerID=8YFLogxK

U2 - 10.1016/j.aca.2015.05.037

DO - 10.1016/j.aca.2015.05.037

M3 - Article

C2 - 26320648

AN - SCOPUS:84940448990

VL - 886

SP - 157

EP - 164

JO - Analytica Chimica Acta

JF - Analytica Chimica Acta

SN - 0003-2670

ER -