In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes

Nicole M. Iverson, Paul W. Barone, Mia Shandell, Laura J. Trudel, Selda Sen, Fatih Sen, Vsevolod Ivanov, Esha Atolia, Edgardo Farias, Thomas P. McNicholas, Nigel Reuel, Nicola M.A. Parry, Gerald N. Wogan, Michael S. Strano

Research output: Contribution to journalArticle

159 Citations (Scopus)

Abstract

Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although single-walled carbon nanotubes have been used as highly sensitive detectors for various compounds, their use as in vivo biomarkers requires the simultaneous optimization of various parameters, including biocompatibility, molecular recognition, high fluorescence quantum efficiency and signal transduction. Here we show that a polyethylene glycol ligated copolymer stabilizes near-infrared-fluorescent single-walled carbon nanotubes sensors in solution, enabling intravenous injection into mice and the selective detection of local nitric oxide concentration with a detection limit of 1 μM. The half-life for liver retention is 4 h, with sensors clearing the lungs within 2 h after injection, thus avoiding a dominant route of in vivo nanotoxicology. After localization within the liver, it is possible to follow the transient inflammation using nitric oxide as a marker and signalling molecule. To this end, we also report a spatial-spectral imaging algorithm to deconvolute fluorescence intensity and spatial information from measurements. Finally, we demonstrate that alginate-encapsulated single-walled carbon nanotubes can function as implantable inflammation sensors for nitric oxide detection, with no intrinsic immune reactivity or other adverse response for more than 400 days.

Original languageEnglish (US)
Pages (from-to)873-880
Number of pages8
JournalNature Nanotechnology
Volume8
Issue number11
DOIs
StatePublished - Nov 2013

Fingerprint

Single-walled carbon nanotubes (SWCN)
Nitric oxide
nitric oxide
carbon nanotubes
Tissue
Infrared radiation
Nitric Oxide
liver
Liver
sensors
Sensors
Fluorescence
injection
Molecular recognition
fluorescence
Signal transduction
clearing
biomarkers
Alginate
Biomarkers

ASJC Scopus subject areas

  • Bioengineering
  • Atomic and Molecular Physics, and Optics
  • Biomedical Engineering
  • Materials Science(all)
  • Condensed Matter Physics
  • Electrical and Electronic Engineering

Cite this

In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes. / Iverson, Nicole M.; Barone, Paul W.; Shandell, Mia; Trudel, Laura J.; Sen, Selda; Sen, Fatih; Ivanov, Vsevolod; Atolia, Esha; Farias, Edgardo; McNicholas, Thomas P.; Reuel, Nigel; Parry, Nicola M.A.; Wogan, Gerald N.; Strano, Michael S.

In: Nature Nanotechnology, Vol. 8, No. 11, 11.2013, p. 873-880.

Research output: Contribution to journalArticle

Iverson, NM, Barone, PW, Shandell, M, Trudel, LJ, Sen, S, Sen, F, Ivanov, V, Atolia, E, Farias, E, McNicholas, TP, Reuel, N, Parry, NMA, Wogan, GN & Strano, MS 2013, 'In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes', Nature Nanotechnology, vol. 8, no. 11, pp. 873-880. https://doi.org/10.1038/nnano.2013.222
Iverson, Nicole M. ; Barone, Paul W. ; Shandell, Mia ; Trudel, Laura J. ; Sen, Selda ; Sen, Fatih ; Ivanov, Vsevolod ; Atolia, Esha ; Farias, Edgardo ; McNicholas, Thomas P. ; Reuel, Nigel ; Parry, Nicola M.A. ; Wogan, Gerald N. ; Strano, Michael S. / In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes. In: Nature Nanotechnology. 2013 ; Vol. 8, No. 11. pp. 873-880.
@article{2b501ec1923a490fa7617c9277091d1f,
title = "In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes",
abstract = "Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although single-walled carbon nanotubes have been used as highly sensitive detectors for various compounds, their use as in vivo biomarkers requires the simultaneous optimization of various parameters, including biocompatibility, molecular recognition, high fluorescence quantum efficiency and signal transduction. Here we show that a polyethylene glycol ligated copolymer stabilizes near-infrared-fluorescent single-walled carbon nanotubes sensors in solution, enabling intravenous injection into mice and the selective detection of local nitric oxide concentration with a detection limit of 1 μM. The half-life for liver retention is 4 h, with sensors clearing the lungs within 2 h after injection, thus avoiding a dominant route of in vivo nanotoxicology. After localization within the liver, it is possible to follow the transient inflammation using nitric oxide as a marker and signalling molecule. To this end, we also report a spatial-spectral imaging algorithm to deconvolute fluorescence intensity and spatial information from measurements. Finally, we demonstrate that alginate-encapsulated single-walled carbon nanotubes can function as implantable inflammation sensors for nitric oxide detection, with no intrinsic immune reactivity or other adverse response for more than 400 days.",
author = "Iverson, {Nicole M.} and Barone, {Paul W.} and Mia Shandell and Trudel, {Laura J.} and Selda Sen and Fatih Sen and Vsevolod Ivanov and Esha Atolia and Edgardo Farias and McNicholas, {Thomas P.} and Nigel Reuel and Parry, {Nicola M.A.} and Wogan, {Gerald N.} and Strano, {Michael S.}",
year = "2013",
month = "11",
doi = "10.1038/nnano.2013.222",
language = "English (US)",
volume = "8",
pages = "873--880",
journal = "Nature Nanotechnology",
issn = "1748-3387",
publisher = "Nature Publishing Group",
number = "11",

}

TY - JOUR

T1 - In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubes

AU - Iverson, Nicole M.

AU - Barone, Paul W.

AU - Shandell, Mia

AU - Trudel, Laura J.

AU - Sen, Selda

AU - Sen, Fatih

AU - Ivanov, Vsevolod

AU - Atolia, Esha

AU - Farias, Edgardo

AU - McNicholas, Thomas P.

AU - Reuel, Nigel

AU - Parry, Nicola M.A.

AU - Wogan, Gerald N.

AU - Strano, Michael S.

PY - 2013/11

Y1 - 2013/11

N2 - Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although single-walled carbon nanotubes have been used as highly sensitive detectors for various compounds, their use as in vivo biomarkers requires the simultaneous optimization of various parameters, including biocompatibility, molecular recognition, high fluorescence quantum efficiency and signal transduction. Here we show that a polyethylene glycol ligated copolymer stabilizes near-infrared-fluorescent single-walled carbon nanotubes sensors in solution, enabling intravenous injection into mice and the selective detection of local nitric oxide concentration with a detection limit of 1 μM. The half-life for liver retention is 4 h, with sensors clearing the lungs within 2 h after injection, thus avoiding a dominant route of in vivo nanotoxicology. After localization within the liver, it is possible to follow the transient inflammation using nitric oxide as a marker and signalling molecule. To this end, we also report a spatial-spectral imaging algorithm to deconvolute fluorescence intensity and spatial information from measurements. Finally, we demonstrate that alginate-encapsulated single-walled carbon nanotubes can function as implantable inflammation sensors for nitric oxide detection, with no intrinsic immune reactivity or other adverse response for more than 400 days.

AB - Single-walled carbon nanotubes are particularly attractive for biomedical applications, because they exhibit a fluorescent signal in a spectral region where there is minimal interference from biological media. Although single-walled carbon nanotubes have been used as highly sensitive detectors for various compounds, their use as in vivo biomarkers requires the simultaneous optimization of various parameters, including biocompatibility, molecular recognition, high fluorescence quantum efficiency and signal transduction. Here we show that a polyethylene glycol ligated copolymer stabilizes near-infrared-fluorescent single-walled carbon nanotubes sensors in solution, enabling intravenous injection into mice and the selective detection of local nitric oxide concentration with a detection limit of 1 μM. The half-life for liver retention is 4 h, with sensors clearing the lungs within 2 h after injection, thus avoiding a dominant route of in vivo nanotoxicology. After localization within the liver, it is possible to follow the transient inflammation using nitric oxide as a marker and signalling molecule. To this end, we also report a spatial-spectral imaging algorithm to deconvolute fluorescence intensity and spatial information from measurements. Finally, we demonstrate that alginate-encapsulated single-walled carbon nanotubes can function as implantable inflammation sensors for nitric oxide detection, with no intrinsic immune reactivity or other adverse response for more than 400 days.

UR - http://www.scopus.com/inward/record.url?scp=84888386417&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84888386417&partnerID=8YFLogxK

U2 - 10.1038/nnano.2013.222

DO - 10.1038/nnano.2013.222

M3 - Article

C2 - 24185942

AN - SCOPUS:84888386417

VL - 8

SP - 873

EP - 880

JO - Nature Nanotechnology

JF - Nature Nanotechnology

SN - 1748-3387

IS - 11

ER -