Improved sonothrombolysis from a modified diagnostic transducer delivering impulses containing a longer pulse duration

Juefei Wu, Feng Xie, Tanmay Kumar, Jinjin Liu, John Lof, William Shi, E. Carr Everbach, Thomas Richard Porter

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Although guided high-mechanical-index (MI) impulses from a diagnostic ultrasound transducer have been used in preclinical studies to dissolve coronary arterial and microvascular thrombi in the presence of intravenously infused microbubbles, it is possible that pulse durations (PDs) longer than that used for diagnostic imaging may further improve the effectiveness of this approach. By use of an established invitro model flow system, a total of 90 occlusive porcine arterial thrombi (thrombus age: 3-4 h) within a vascular mimicking system were randomized to 10-min treatments with two different PDs (5 and 20 μs) using a Philips S5-1 transducer (1.6-MHz center frequency) at a range of MIs (from 0.2 to 1.4). All impulses were delivered in an intermittent fashion to permit microbubble replenishment within the thrombosed vessel. Diluted lipid-encapsulated microbubbles (0.5% Definity) were infused during the entire treatment period. A tissue-mimicking phantom 5 cm thick was placed between the transducer and thrombosed vessel to mimic transthoracic attenuation. Two 20-MHz passive cavitation detection systems were placed confocal to the insonified vessel to assess for inertial cavitational activity. Percentage thrombus dissolution was calculated by weighing the thrombi before and after each treatment. Percentage thrombus dissolution was significantly higher with a 20-μs PD already at the 0.2 and 0.4 MI therapeutic impulses (54 ± 12% vs. 33 ± 17% and 54 ± 22% vs. 34 ± 17%, p < 0.05 compared with the 5-μs PD group, respectively), and where passive cavitation detection systems detected only low intensities of inertial cavitation. At higher MI settings and 20-μs PDs, percentage thrombus dissolution decreased most likely from high-intensity cavitation shielding of the thrombus. Slightly prolonging the PD on a diagnostic transducer improves the degree of sonothrombolysis that can be achieved without fibrinolytic agents at a lower mechanical index.

Original languageEnglish (US)
Pages (from-to)1545-1553
Number of pages9
JournalUltrasound in Medicine and Biology
Volume40
Issue number7
DOIs
StatePublished - Jan 1 2014

Fingerprint

Transducers
impulses
transducers
pulse duration
Thrombosis
cavitation flow
vessels
dissolving
Microbubbles
Pulse
cardiovascular system
replenishment
shielding
lipids
attenuation
Fibrinolytic Agents
Diagnostic Imaging
Blood Vessels
Ultrasonography
Swine

Keywords

  • Imaging
  • Thrombolysis
  • Ultrasound

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Biophysics
  • Acoustics and Ultrasonics

Cite this

Improved sonothrombolysis from a modified diagnostic transducer delivering impulses containing a longer pulse duration. / Wu, Juefei; Xie, Feng; Kumar, Tanmay; Liu, Jinjin; Lof, John; Shi, William; Everbach, E. Carr; Porter, Thomas Richard.

In: Ultrasound in Medicine and Biology, Vol. 40, No. 7, 01.01.2014, p. 1545-1553.

Research output: Contribution to journalArticle

Wu, Juefei ; Xie, Feng ; Kumar, Tanmay ; Liu, Jinjin ; Lof, John ; Shi, William ; Everbach, E. Carr ; Porter, Thomas Richard. / Improved sonothrombolysis from a modified diagnostic transducer delivering impulses containing a longer pulse duration. In: Ultrasound in Medicine and Biology. 2014 ; Vol. 40, No. 7. pp. 1545-1553.
@article{d312afa7fd9c4c8f92746fd49d817c0c,
title = "Improved sonothrombolysis from a modified diagnostic transducer delivering impulses containing a longer pulse duration",
abstract = "Although guided high-mechanical-index (MI) impulses from a diagnostic ultrasound transducer have been used in preclinical studies to dissolve coronary arterial and microvascular thrombi in the presence of intravenously infused microbubbles, it is possible that pulse durations (PDs) longer than that used for diagnostic imaging may further improve the effectiveness of this approach. By use of an established invitro model flow system, a total of 90 occlusive porcine arterial thrombi (thrombus age: 3-4 h) within a vascular mimicking system were randomized to 10-min treatments with two different PDs (5 and 20 μs) using a Philips S5-1 transducer (1.6-MHz center frequency) at a range of MIs (from 0.2 to 1.4). All impulses were delivered in an intermittent fashion to permit microbubble replenishment within the thrombosed vessel. Diluted lipid-encapsulated microbubbles (0.5{\%} Definity) were infused during the entire treatment period. A tissue-mimicking phantom 5 cm thick was placed between the transducer and thrombosed vessel to mimic transthoracic attenuation. Two 20-MHz passive cavitation detection systems were placed confocal to the insonified vessel to assess for inertial cavitational activity. Percentage thrombus dissolution was calculated by weighing the thrombi before and after each treatment. Percentage thrombus dissolution was significantly higher with a 20-μs PD already at the 0.2 and 0.4 MI therapeutic impulses (54 ± 12{\%} vs. 33 ± 17{\%} and 54 ± 22{\%} vs. 34 ± 17{\%}, p < 0.05 compared with the 5-μs PD group, respectively), and where passive cavitation detection systems detected only low intensities of inertial cavitation. At higher MI settings and 20-μs PDs, percentage thrombus dissolution decreased most likely from high-intensity cavitation shielding of the thrombus. Slightly prolonging the PD on a diagnostic transducer improves the degree of sonothrombolysis that can be achieved without fibrinolytic agents at a lower mechanical index.",
keywords = "Imaging, Thrombolysis, Ultrasound",
author = "Juefei Wu and Feng Xie and Tanmay Kumar and Jinjin Liu and John Lof and William Shi and Everbach, {E. Carr} and Porter, {Thomas Richard}",
year = "2014",
month = "1",
day = "1",
doi = "10.1016/j.ultrasmedbio.2014.01.015",
language = "English (US)",
volume = "40",
pages = "1545--1553",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier USA",
number = "7",

}

TY - JOUR

T1 - Improved sonothrombolysis from a modified diagnostic transducer delivering impulses containing a longer pulse duration

AU - Wu, Juefei

AU - Xie, Feng

AU - Kumar, Tanmay

AU - Liu, Jinjin

AU - Lof, John

AU - Shi, William

AU - Everbach, E. Carr

AU - Porter, Thomas Richard

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Although guided high-mechanical-index (MI) impulses from a diagnostic ultrasound transducer have been used in preclinical studies to dissolve coronary arterial and microvascular thrombi in the presence of intravenously infused microbubbles, it is possible that pulse durations (PDs) longer than that used for diagnostic imaging may further improve the effectiveness of this approach. By use of an established invitro model flow system, a total of 90 occlusive porcine arterial thrombi (thrombus age: 3-4 h) within a vascular mimicking system were randomized to 10-min treatments with two different PDs (5 and 20 μs) using a Philips S5-1 transducer (1.6-MHz center frequency) at a range of MIs (from 0.2 to 1.4). All impulses were delivered in an intermittent fashion to permit microbubble replenishment within the thrombosed vessel. Diluted lipid-encapsulated microbubbles (0.5% Definity) were infused during the entire treatment period. A tissue-mimicking phantom 5 cm thick was placed between the transducer and thrombosed vessel to mimic transthoracic attenuation. Two 20-MHz passive cavitation detection systems were placed confocal to the insonified vessel to assess for inertial cavitational activity. Percentage thrombus dissolution was calculated by weighing the thrombi before and after each treatment. Percentage thrombus dissolution was significantly higher with a 20-μs PD already at the 0.2 and 0.4 MI therapeutic impulses (54 ± 12% vs. 33 ± 17% and 54 ± 22% vs. 34 ± 17%, p < 0.05 compared with the 5-μs PD group, respectively), and where passive cavitation detection systems detected only low intensities of inertial cavitation. At higher MI settings and 20-μs PDs, percentage thrombus dissolution decreased most likely from high-intensity cavitation shielding of the thrombus. Slightly prolonging the PD on a diagnostic transducer improves the degree of sonothrombolysis that can be achieved without fibrinolytic agents at a lower mechanical index.

AB - Although guided high-mechanical-index (MI) impulses from a diagnostic ultrasound transducer have been used in preclinical studies to dissolve coronary arterial and microvascular thrombi in the presence of intravenously infused microbubbles, it is possible that pulse durations (PDs) longer than that used for diagnostic imaging may further improve the effectiveness of this approach. By use of an established invitro model flow system, a total of 90 occlusive porcine arterial thrombi (thrombus age: 3-4 h) within a vascular mimicking system were randomized to 10-min treatments with two different PDs (5 and 20 μs) using a Philips S5-1 transducer (1.6-MHz center frequency) at a range of MIs (from 0.2 to 1.4). All impulses were delivered in an intermittent fashion to permit microbubble replenishment within the thrombosed vessel. Diluted lipid-encapsulated microbubbles (0.5% Definity) were infused during the entire treatment period. A tissue-mimicking phantom 5 cm thick was placed between the transducer and thrombosed vessel to mimic transthoracic attenuation. Two 20-MHz passive cavitation detection systems were placed confocal to the insonified vessel to assess for inertial cavitational activity. Percentage thrombus dissolution was calculated by weighing the thrombi before and after each treatment. Percentage thrombus dissolution was significantly higher with a 20-μs PD already at the 0.2 and 0.4 MI therapeutic impulses (54 ± 12% vs. 33 ± 17% and 54 ± 22% vs. 34 ± 17%, p < 0.05 compared with the 5-μs PD group, respectively), and where passive cavitation detection systems detected only low intensities of inertial cavitation. At higher MI settings and 20-μs PDs, percentage thrombus dissolution decreased most likely from high-intensity cavitation shielding of the thrombus. Slightly prolonging the PD on a diagnostic transducer improves the degree of sonothrombolysis that can be achieved without fibrinolytic agents at a lower mechanical index.

KW - Imaging

KW - Thrombolysis

KW - Ultrasound

UR - http://www.scopus.com/inward/record.url?scp=84901988445&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84901988445&partnerID=8YFLogxK

U2 - 10.1016/j.ultrasmedbio.2014.01.015

DO - 10.1016/j.ultrasmedbio.2014.01.015

M3 - Article

VL - 40

SP - 1545

EP - 1553

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 7

ER -