Implementation of 0.7 in. diameter strands at 2.0 × 2.0 in. spacing in pretensioned Bridge girders

George Morcous, Shaddi Assad, Afshin Hatami, Maher K. Tadros

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Use of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing in pretensioned concrete girders results in an approximately 35% increase in the prestressing force compared with the same number of 0.6 in. (15 mm) strands and a 92% increase in the prestressing force compared with the same number of 0.5 in. (13 mm) strands, allowing for longer spans, shallower depths, and/or wider girder spacing. This paper presents the application of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing to the Oxford South Bridge in Oxford, Neb. Twenty-six strand samples were tested for breaking strength, yield strength, and modulus of elasticity. The strands met the requirements of ASTM A416-07.Transfer lengths were measured at three locations on two girders at release and after 14 days. Measurements indicated that the transfer length of 0.7 in. diameter strands can be conservatively estimated using the AASHTO LRFD Bridge Design Specifications. All girders were monitored for end zone cracking and camber growth and were found in compliance with current production tolerances, as specified by PCI and the Nebraska Department of Roads.

Original languageEnglish (US)
Pages (from-to)145-158
Number of pages14
JournalPCI Journal
Volume59
Issue number3
DOIs
StatePublished - Jan 1 2014

Fingerprint

Prestressing
Beams and girders
Concrete beams and girders
Cambers
Yield stress
Elastic moduli
Specifications
Compliance

Keywords

  • Bridge
  • Camber
  • Cracking
  • Girder
  • Strand
  • Transfer length

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Materials Science(all)
  • Mechanics of Materials

Cite this

Implementation of 0.7 in. diameter strands at 2.0 × 2.0 in. spacing in pretensioned Bridge girders. / Morcous, George; Assad, Shaddi; Hatami, Afshin; Tadros, Maher K.

In: PCI Journal, Vol. 59, No. 3, 01.01.2014, p. 145-158.

Research output: Contribution to journalArticle

Morcous, George ; Assad, Shaddi ; Hatami, Afshin ; Tadros, Maher K. / Implementation of 0.7 in. diameter strands at 2.0 × 2.0 in. spacing in pretensioned Bridge girders. In: PCI Journal. 2014 ; Vol. 59, No. 3. pp. 145-158.
@article{80f3e810918a442e8f179c347a0b35f0,
title = "Implementation of 0.7 in. diameter strands at 2.0 × 2.0 in. spacing in pretensioned Bridge girders",
abstract = "Use of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing in pretensioned concrete girders results in an approximately 35{\%} increase in the prestressing force compared with the same number of 0.6 in. (15 mm) strands and a 92{\%} increase in the prestressing force compared with the same number of 0.5 in. (13 mm) strands, allowing for longer spans, shallower depths, and/or wider girder spacing. This paper presents the application of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing to the Oxford South Bridge in Oxford, Neb. Twenty-six strand samples were tested for breaking strength, yield strength, and modulus of elasticity. The strands met the requirements of ASTM A416-07.Transfer lengths were measured at three locations on two girders at release and after 14 days. Measurements indicated that the transfer length of 0.7 in. diameter strands can be conservatively estimated using the AASHTO LRFD Bridge Design Specifications. All girders were monitored for end zone cracking and camber growth and were found in compliance with current production tolerances, as specified by PCI and the Nebraska Department of Roads.",
keywords = "Bridge, Camber, Cracking, Girder, Strand, Transfer length",
author = "George Morcous and Shaddi Assad and Afshin Hatami and Tadros, {Maher K.}",
year = "2014",
month = "1",
day = "1",
doi = "10.15554/pcij.06012014.145.158",
language = "English (US)",
volume = "59",
pages = "145--158",
journal = "Journal of the Prestressed Concrete Institute",
issn = "0887-9672",
publisher = "Precast/Prestressed Concrete Institute",
number = "3",

}

TY - JOUR

T1 - Implementation of 0.7 in. diameter strands at 2.0 × 2.0 in. spacing in pretensioned Bridge girders

AU - Morcous, George

AU - Assad, Shaddi

AU - Hatami, Afshin

AU - Tadros, Maher K.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Use of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing in pretensioned concrete girders results in an approximately 35% increase in the prestressing force compared with the same number of 0.6 in. (15 mm) strands and a 92% increase in the prestressing force compared with the same number of 0.5 in. (13 mm) strands, allowing for longer spans, shallower depths, and/or wider girder spacing. This paper presents the application of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing to the Oxford South Bridge in Oxford, Neb. Twenty-six strand samples were tested for breaking strength, yield strength, and modulus of elasticity. The strands met the requirements of ASTM A416-07.Transfer lengths were measured at three locations on two girders at release and after 14 days. Measurements indicated that the transfer length of 0.7 in. diameter strands can be conservatively estimated using the AASHTO LRFD Bridge Design Specifications. All girders were monitored for end zone cracking and camber growth and were found in compliance with current production tolerances, as specified by PCI and the Nebraska Department of Roads.

AB - Use of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing in pretensioned concrete girders results in an approximately 35% increase in the prestressing force compared with the same number of 0.6 in. (15 mm) strands and a 92% increase in the prestressing force compared with the same number of 0.5 in. (13 mm) strands, allowing for longer spans, shallower depths, and/or wider girder spacing. This paper presents the application of 0.7 in. (18 mm) diameter strands at 2 × 2 in. (50 × 50 mm) spacing to the Oxford South Bridge in Oxford, Neb. Twenty-six strand samples were tested for breaking strength, yield strength, and modulus of elasticity. The strands met the requirements of ASTM A416-07.Transfer lengths were measured at three locations on two girders at release and after 14 days. Measurements indicated that the transfer length of 0.7 in. diameter strands can be conservatively estimated using the AASHTO LRFD Bridge Design Specifications. All girders were monitored for end zone cracking and camber growth and were found in compliance with current production tolerances, as specified by PCI and the Nebraska Department of Roads.

KW - Bridge

KW - Camber

KW - Cracking

KW - Girder

KW - Strand

KW - Transfer length

UR - http://www.scopus.com/inward/record.url?scp=84903614570&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84903614570&partnerID=8YFLogxK

U2 - 10.15554/pcij.06012014.145.158

DO - 10.15554/pcij.06012014.145.158

M3 - Article

AN - SCOPUS:84903614570

VL - 59

SP - 145

EP - 158

JO - Journal of the Prestressed Concrete Institute

JF - Journal of the Prestressed Concrete Institute

SN - 0887-9672

IS - 3

ER -