Image deconvolution in digital autoradiography

A preliminary study

Mutian Zhang, Qing Chen, Xiao Feng Li, Joseph O'Donoghue, Shutian Ruan, Pat Zanzonico, C. Clifton Ling, John L. Humm

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Digital autoradiography (DAR) is a powerful method to determine quantitatively the "small-scale" (i.e., submillimeter) distribution of a radiotracer within a tissue section. However, the limited spatial resolution of the DAR image, due to blurring by the point spread function (PSF), can result in a poor correlation with tissue histology and immunohistochemistry. The authors attempt to overcome this limitation by recovering the radiotracer distribution by image deconvolution using the Richardson-Lucy algorithm and a measured PSF obtained from a small radioactive source on hydrophobic microscope slide. Simulation studies have shown that the deconvolution algorithm reliably recovers the pixel values corresponding to the radioactivity distributions. As an example, the proposed image restoration approach has been tested with DAR images of different radiolabeled markers on tumor sections obtained from clinical and preclinical animal model studies. Digital autoradiograms following deconvolution show improved sharpness and contrast relative to the unprocessed autoradiograms.

Original languageEnglish (US)
Pages (from-to)522-530
Number of pages9
JournalMedical Physics
Volume35
Issue number2
DOIs
StatePublished - Jan 1 2008

Fingerprint

Autoradiography
Tumor Biomarkers
Radioactivity
Histology
Animal Models
Immunohistochemistry

Keywords

  • Digital autoradiography
  • Image deconvolution
  • Imaging plate
  • Point spread function
  • Richardson-Lucy algorithm

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

Zhang, M., Chen, Q., Li, X. F., O'Donoghue, J., Ruan, S., Zanzonico, P., ... Humm, J. L. (2008). Image deconvolution in digital autoradiography: A preliminary study. Medical Physics, 35(2), 522-530. https://doi.org/10.1118/1.2828198

Image deconvolution in digital autoradiography : A preliminary study. / Zhang, Mutian; Chen, Qing; Li, Xiao Feng; O'Donoghue, Joseph; Ruan, Shutian; Zanzonico, Pat; Ling, C. Clifton; Humm, John L.

In: Medical Physics, Vol. 35, No. 2, 01.01.2008, p. 522-530.

Research output: Contribution to journalArticle

Zhang, M, Chen, Q, Li, XF, O'Donoghue, J, Ruan, S, Zanzonico, P, Ling, CC & Humm, JL 2008, 'Image deconvolution in digital autoradiography: A preliminary study', Medical Physics, vol. 35, no. 2, pp. 522-530. https://doi.org/10.1118/1.2828198
Zhang M, Chen Q, Li XF, O'Donoghue J, Ruan S, Zanzonico P et al. Image deconvolution in digital autoradiography: A preliminary study. Medical Physics. 2008 Jan 1;35(2):522-530. https://doi.org/10.1118/1.2828198
Zhang, Mutian ; Chen, Qing ; Li, Xiao Feng ; O'Donoghue, Joseph ; Ruan, Shutian ; Zanzonico, Pat ; Ling, C. Clifton ; Humm, John L. / Image deconvolution in digital autoradiography : A preliminary study. In: Medical Physics. 2008 ; Vol. 35, No. 2. pp. 522-530.
@article{142cd07d05564c9ea69601e0745ea0e0,
title = "Image deconvolution in digital autoradiography: A preliminary study",
abstract = "Digital autoradiography (DAR) is a powerful method to determine quantitatively the {"}small-scale{"} (i.e., submillimeter) distribution of a radiotracer within a tissue section. However, the limited spatial resolution of the DAR image, due to blurring by the point spread function (PSF), can result in a poor correlation with tissue histology and immunohistochemistry. The authors attempt to overcome this limitation by recovering the radiotracer distribution by image deconvolution using the Richardson-Lucy algorithm and a measured PSF obtained from a small radioactive source on hydrophobic microscope slide. Simulation studies have shown that the deconvolution algorithm reliably recovers the pixel values corresponding to the radioactivity distributions. As an example, the proposed image restoration approach has been tested with DAR images of different radiolabeled markers on tumor sections obtained from clinical and preclinical animal model studies. Digital autoradiograms following deconvolution show improved sharpness and contrast relative to the unprocessed autoradiograms.",
keywords = "Digital autoradiography, Image deconvolution, Imaging plate, Point spread function, Richardson-Lucy algorithm",
author = "Mutian Zhang and Qing Chen and Li, {Xiao Feng} and Joseph O'Donoghue and Shutian Ruan and Pat Zanzonico and Ling, {C. Clifton} and Humm, {John L.}",
year = "2008",
month = "1",
day = "1",
doi = "10.1118/1.2828198",
language = "English (US)",
volume = "35",
pages = "522--530",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "2",

}

TY - JOUR

T1 - Image deconvolution in digital autoradiography

T2 - A preliminary study

AU - Zhang, Mutian

AU - Chen, Qing

AU - Li, Xiao Feng

AU - O'Donoghue, Joseph

AU - Ruan, Shutian

AU - Zanzonico, Pat

AU - Ling, C. Clifton

AU - Humm, John L.

PY - 2008/1/1

Y1 - 2008/1/1

N2 - Digital autoradiography (DAR) is a powerful method to determine quantitatively the "small-scale" (i.e., submillimeter) distribution of a radiotracer within a tissue section. However, the limited spatial resolution of the DAR image, due to blurring by the point spread function (PSF), can result in a poor correlation with tissue histology and immunohistochemistry. The authors attempt to overcome this limitation by recovering the radiotracer distribution by image deconvolution using the Richardson-Lucy algorithm and a measured PSF obtained from a small radioactive source on hydrophobic microscope slide. Simulation studies have shown that the deconvolution algorithm reliably recovers the pixel values corresponding to the radioactivity distributions. As an example, the proposed image restoration approach has been tested with DAR images of different radiolabeled markers on tumor sections obtained from clinical and preclinical animal model studies. Digital autoradiograms following deconvolution show improved sharpness and contrast relative to the unprocessed autoradiograms.

AB - Digital autoradiography (DAR) is a powerful method to determine quantitatively the "small-scale" (i.e., submillimeter) distribution of a radiotracer within a tissue section. However, the limited spatial resolution of the DAR image, due to blurring by the point spread function (PSF), can result in a poor correlation with tissue histology and immunohistochemistry. The authors attempt to overcome this limitation by recovering the radiotracer distribution by image deconvolution using the Richardson-Lucy algorithm and a measured PSF obtained from a small radioactive source on hydrophobic microscope slide. Simulation studies have shown that the deconvolution algorithm reliably recovers the pixel values corresponding to the radioactivity distributions. As an example, the proposed image restoration approach has been tested with DAR images of different radiolabeled markers on tumor sections obtained from clinical and preclinical animal model studies. Digital autoradiograms following deconvolution show improved sharpness and contrast relative to the unprocessed autoradiograms.

KW - Digital autoradiography

KW - Image deconvolution

KW - Imaging plate

KW - Point spread function

KW - Richardson-Lucy algorithm

UR - http://www.scopus.com/inward/record.url?scp=38849127416&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=38849127416&partnerID=8YFLogxK

U2 - 10.1118/1.2828198

DO - 10.1118/1.2828198

M3 - Article

VL - 35

SP - 522

EP - 530

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 2

ER -