Hemodynamics and wall mechanics after surgical repair of aortic arch: Implication for better clinical decisions

Siyeong Ju, Ibrahim Abdullah, Shengmao Lin, Linxia Gu

Research output: Contribution to journalArticle

Abstract

Graft repair of aortic coarctation is commonly used to mimic the physiological aortic arch shape and function. Various graft materials and shapes have been adopted for the surgery. The goal of this work is to quantitatively assess the impact of graft materials and shapes in the hemodynamics and wall mechanics of the restored aortic arch and its correlation with clinical outcomes. A three-dimensional aortic arch model was reconstructed from magnetic resonance images. The fluid-structure interaction (FSI) analysis was performed to characterize the hemodynamics and solid wall mechanics of the repaired aortic arch. Two graft shapes (i.e., a half-moon shape and a crescent one) were considered. Material choices of the aortic arch repair included three commonly used graft materials (i.e., polytetrafluoroethylene (PTFE) synthetic graft, CorMatrix extracellular matrix, and pulmonary homograft) as well as one native tissue serving as a control. The pathological hemodynamic parameters, in terms of the percentage area of low wall shear stress (WSS), high oscillatory shear index (OSI), and high relative residence time (RRT), were quantified to be associated with potential clinical outcomes. Results have shown that the peak von Mises stress for the aortic arch repaired by the crescent graft was 76% less than that of the half-moon graft. Flow disturbance and recirculation were also minimized with the crescent graft. Moreover, pathological hemodynamic parameters were significantly reduced with the crescent graft. The graft material mismatch with the surrounding tissue aggregated the stress concentration on the aortic wall, but had minimal impact on flow dynamics. The present work demonstrated the role and importance of the graft geometry and materials on hemodynamics and wall mechanics, which could guide optimal graft decisions towards better clinical outcomes.

Original languageEnglish (US)
Article number807
JournalApplied Sciences (Switzerland)
Volume9
Issue number4
DOIs
StatePublished - Feb 25 2019

Fingerprint

hemodynamics
arches
Hemodynamics
Arches
Grafts
Mechanics
Repair
natural satellites
stress concentration
polytetrafluoroethylene
Moon
surgery
shear stress
magnetic resonance
disturbances
shear
Tissue
fluids
Fluid structure interaction
matrices

Keywords

  • Aortic arch
  • Aortic coarctation
  • Crescent
  • Fluid-structure interaction
  • Graft repair
  • Half-moon
  • Mechanics

ASJC Scopus subject areas

  • Materials Science(all)
  • Instrumentation
  • Engineering(all)
  • Process Chemistry and Technology
  • Computer Science Applications
  • Fluid Flow and Transfer Processes

Cite this

Hemodynamics and wall mechanics after surgical repair of aortic arch : Implication for better clinical decisions. / Ju, Siyeong; Abdullah, Ibrahim; Lin, Shengmao; Gu, Linxia.

In: Applied Sciences (Switzerland), Vol. 9, No. 4, 807, 25.02.2019.

Research output: Contribution to journalArticle

@article{39d175204bf349d389f03ba892229330,
title = "Hemodynamics and wall mechanics after surgical repair of aortic arch: Implication for better clinical decisions",
abstract = "Graft repair of aortic coarctation is commonly used to mimic the physiological aortic arch shape and function. Various graft materials and shapes have been adopted for the surgery. The goal of this work is to quantitatively assess the impact of graft materials and shapes in the hemodynamics and wall mechanics of the restored aortic arch and its correlation with clinical outcomes. A three-dimensional aortic arch model was reconstructed from magnetic resonance images. The fluid-structure interaction (FSI) analysis was performed to characterize the hemodynamics and solid wall mechanics of the repaired aortic arch. Two graft shapes (i.e., a half-moon shape and a crescent one) were considered. Material choices of the aortic arch repair included three commonly used graft materials (i.e., polytetrafluoroethylene (PTFE) synthetic graft, CorMatrix extracellular matrix, and pulmonary homograft) as well as one native tissue serving as a control. The pathological hemodynamic parameters, in terms of the percentage area of low wall shear stress (WSS), high oscillatory shear index (OSI), and high relative residence time (RRT), were quantified to be associated with potential clinical outcomes. Results have shown that the peak von Mises stress for the aortic arch repaired by the crescent graft was 76{\%} less than that of the half-moon graft. Flow disturbance and recirculation were also minimized with the crescent graft. Moreover, pathological hemodynamic parameters were significantly reduced with the crescent graft. The graft material mismatch with the surrounding tissue aggregated the stress concentration on the aortic wall, but had minimal impact on flow dynamics. The present work demonstrated the role and importance of the graft geometry and materials on hemodynamics and wall mechanics, which could guide optimal graft decisions towards better clinical outcomes.",
keywords = "Aortic arch, Aortic coarctation, Crescent, Fluid-structure interaction, Graft repair, Half-moon, Mechanics",
author = "Siyeong Ju and Ibrahim Abdullah and Shengmao Lin and Linxia Gu",
year = "2019",
month = "2",
day = "25",
doi = "10.3390/app9040807",
language = "English (US)",
volume = "9",
journal = "Applied Sciences (Switzerland)",
issn = "2076-3417",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "4",

}

TY - JOUR

T1 - Hemodynamics and wall mechanics after surgical repair of aortic arch

T2 - Implication for better clinical decisions

AU - Ju, Siyeong

AU - Abdullah, Ibrahim

AU - Lin, Shengmao

AU - Gu, Linxia

PY - 2019/2/25

Y1 - 2019/2/25

N2 - Graft repair of aortic coarctation is commonly used to mimic the physiological aortic arch shape and function. Various graft materials and shapes have been adopted for the surgery. The goal of this work is to quantitatively assess the impact of graft materials and shapes in the hemodynamics and wall mechanics of the restored aortic arch and its correlation with clinical outcomes. A three-dimensional aortic arch model was reconstructed from magnetic resonance images. The fluid-structure interaction (FSI) analysis was performed to characterize the hemodynamics and solid wall mechanics of the repaired aortic arch. Two graft shapes (i.e., a half-moon shape and a crescent one) were considered. Material choices of the aortic arch repair included three commonly used graft materials (i.e., polytetrafluoroethylene (PTFE) synthetic graft, CorMatrix extracellular matrix, and pulmonary homograft) as well as one native tissue serving as a control. The pathological hemodynamic parameters, in terms of the percentage area of low wall shear stress (WSS), high oscillatory shear index (OSI), and high relative residence time (RRT), were quantified to be associated with potential clinical outcomes. Results have shown that the peak von Mises stress for the aortic arch repaired by the crescent graft was 76% less than that of the half-moon graft. Flow disturbance and recirculation were also minimized with the crescent graft. Moreover, pathological hemodynamic parameters were significantly reduced with the crescent graft. The graft material mismatch with the surrounding tissue aggregated the stress concentration on the aortic wall, but had minimal impact on flow dynamics. The present work demonstrated the role and importance of the graft geometry and materials on hemodynamics and wall mechanics, which could guide optimal graft decisions towards better clinical outcomes.

AB - Graft repair of aortic coarctation is commonly used to mimic the physiological aortic arch shape and function. Various graft materials and shapes have been adopted for the surgery. The goal of this work is to quantitatively assess the impact of graft materials and shapes in the hemodynamics and wall mechanics of the restored aortic arch and its correlation with clinical outcomes. A three-dimensional aortic arch model was reconstructed from magnetic resonance images. The fluid-structure interaction (FSI) analysis was performed to characterize the hemodynamics and solid wall mechanics of the repaired aortic arch. Two graft shapes (i.e., a half-moon shape and a crescent one) were considered. Material choices of the aortic arch repair included three commonly used graft materials (i.e., polytetrafluoroethylene (PTFE) synthetic graft, CorMatrix extracellular matrix, and pulmonary homograft) as well as one native tissue serving as a control. The pathological hemodynamic parameters, in terms of the percentage area of low wall shear stress (WSS), high oscillatory shear index (OSI), and high relative residence time (RRT), were quantified to be associated with potential clinical outcomes. Results have shown that the peak von Mises stress for the aortic arch repaired by the crescent graft was 76% less than that of the half-moon graft. Flow disturbance and recirculation were also minimized with the crescent graft. Moreover, pathological hemodynamic parameters were significantly reduced with the crescent graft. The graft material mismatch with the surrounding tissue aggregated the stress concentration on the aortic wall, but had minimal impact on flow dynamics. The present work demonstrated the role and importance of the graft geometry and materials on hemodynamics and wall mechanics, which could guide optimal graft decisions towards better clinical outcomes.

KW - Aortic arch

KW - Aortic coarctation

KW - Crescent

KW - Fluid-structure interaction

KW - Graft repair

KW - Half-moon

KW - Mechanics

UR - http://www.scopus.com/inward/record.url?scp=85062156681&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85062156681&partnerID=8YFLogxK

U2 - 10.3390/app9040807

DO - 10.3390/app9040807

M3 - Article

AN - SCOPUS:85062156681

VL - 9

JO - Applied Sciences (Switzerland)

JF - Applied Sciences (Switzerland)

SN - 2076-3417

IS - 4

M1 - 807

ER -