BACKGROUND AND OBJECTIVE: To study the heat and power dissipation effect of an intraocular electronic heater on the retina. The determination of thermal parameters that are nonharmful to the retina will aid in the development of an implantable intraocular electronic retinal prosthesis. MATERIALS AND METHODS: In dogs, five different retinal areas were touched with a custom intraocular heater probe (1.4 X 1.4 X 1.0 mm) for 1 second while the heater dissipated 0 (control), 10, 20, 50, or 100 mW. In a second protocol, the heater was mechanically held in the vitreous cavity while dissipating 500 mW for 2 hours while monitoring intraocular temperature. The animals were observed for 4 weeks with serial fundus photography and electroretinography. The procedure was then repeated in the fellow eye. The dogs were killed and both eyes were enucleated and submitted for histology. RESULTS: In experiments using protocol 1, heater settings of 50 mW or higher caused an immediate visible whitening of the retinal tissue. Histologically, this damage was evident only if the eyes were immediately enucleated. Permanent damage was caused by heater settings of 100 mW or higher. Under protocol 2, no ophthalmologic, electroretinography, or histologic differences were noted between the groups. Temperature increases of 5°C in the vitreous and 2°C near the retina were noted. CONCLUSIONS: The liquid environment of the eye acts as a heat sink that is capable of dissipating a significant amount of power. An electronic chip positioned away from the retina can run at considerably higher powers than a chip positioned on the retinal surface.

Original languageEnglish (US)
Pages (from-to)114-120
Number of pages7
JournalOphthalmic Surgery Lasers and Imaging
Volume34
Issue number2
StatePublished - Mar 1 2003

Fingerprint

Retina
Hot Temperature
Electroretinography
Visual Prosthesis
Dogs
Temperature
Photography
Histology

ASJC Scopus subject areas

  • Surgery
  • Ophthalmology

Cite this

Piyathaisere, D. V., Margalit, E., Chen, S. J., Shyu, J. S., D'Anna, S. A., Weiland, J. D., ... Humayun, M. S. (2003). Heat effects on the retina. Ophthalmic Surgery Lasers and Imaging, 34(2), 114-120.

Heat effects on the retina. / Piyathaisere, Duke V.; Margalit, Eyal; Chen, Shih Jen; Shyu, Jeng Shyong; D'Anna, Salvatore A.; Weiland, James D.; Grebe, Rhonda R.; Grebe, Lynnea; Fujii, Gildo; Kim, Sahng Yeon; Greenberg, Robert J.; De Juan, Eugene; Humayun, Mark S.

In: Ophthalmic Surgery Lasers and Imaging, Vol. 34, No. 2, 01.03.2003, p. 114-120.

Research output: Contribution to journalArticle

Piyathaisere, DV, Margalit, E, Chen, SJ, Shyu, JS, D'Anna, SA, Weiland, JD, Grebe, RR, Grebe, L, Fujii, G, Kim, SY, Greenberg, RJ, De Juan, E & Humayun, MS 2003, 'Heat effects on the retina', Ophthalmic Surgery Lasers and Imaging, vol. 34, no. 2, pp. 114-120.
Piyathaisere DV, Margalit E, Chen SJ, Shyu JS, D'Anna SA, Weiland JD et al. Heat effects on the retina. Ophthalmic Surgery Lasers and Imaging. 2003 Mar 1;34(2):114-120.
Piyathaisere, Duke V. ; Margalit, Eyal ; Chen, Shih Jen ; Shyu, Jeng Shyong ; D'Anna, Salvatore A. ; Weiland, James D. ; Grebe, Rhonda R. ; Grebe, Lynnea ; Fujii, Gildo ; Kim, Sahng Yeon ; Greenberg, Robert J. ; De Juan, Eugene ; Humayun, Mark S. / Heat effects on the retina. In: Ophthalmic Surgery Lasers and Imaging. 2003 ; Vol. 34, No. 2. pp. 114-120.
@article{44ba4fca15ba4754a2dfc2f9f91487a8,
title = "Heat effects on the retina",
abstract = "BACKGROUND AND OBJECTIVE: To study the heat and power dissipation effect of an intraocular electronic heater on the retina. The determination of thermal parameters that are nonharmful to the retina will aid in the development of an implantable intraocular electronic retinal prosthesis. MATERIALS AND METHODS: In dogs, five different retinal areas were touched with a custom intraocular heater probe (1.4 X 1.4 X 1.0 mm) for 1 second while the heater dissipated 0 (control), 10, 20, 50, or 100 mW. In a second protocol, the heater was mechanically held in the vitreous cavity while dissipating 500 mW for 2 hours while monitoring intraocular temperature. The animals were observed for 4 weeks with serial fundus photography and electroretinography. The procedure was then repeated in the fellow eye. The dogs were killed and both eyes were enucleated and submitted for histology. RESULTS: In experiments using protocol 1, heater settings of 50 mW or higher caused an immediate visible whitening of the retinal tissue. Histologically, this damage was evident only if the eyes were immediately enucleated. Permanent damage was caused by heater settings of 100 mW or higher. Under protocol 2, no ophthalmologic, electroretinography, or histologic differences were noted between the groups. Temperature increases of 5°C in the vitreous and 2°C near the retina were noted. CONCLUSIONS: The liquid environment of the eye acts as a heat sink that is capable of dissipating a significant amount of power. An electronic chip positioned away from the retina can run at considerably higher powers than a chip positioned on the retinal surface.",
author = "Piyathaisere, {Duke V.} and Eyal Margalit and Chen, {Shih Jen} and Shyu, {Jeng Shyong} and D'Anna, {Salvatore A.} and Weiland, {James D.} and Grebe, {Rhonda R.} and Lynnea Grebe and Gildo Fujii and Kim, {Sahng Yeon} and Greenberg, {Robert J.} and {De Juan}, Eugene and Humayun, {Mark S.}",
year = "2003",
month = "3",
day = "1",
language = "English (US)",
volume = "34",
pages = "114--120",
journal = "Ophthalmic Surgery Lasers and Imaging Retina",
issn = "2325-8160",
publisher = "Slack Incorporated",
number = "2",

}

TY - JOUR

T1 - Heat effects on the retina

AU - Piyathaisere, Duke V.

AU - Margalit, Eyal

AU - Chen, Shih Jen

AU - Shyu, Jeng Shyong

AU - D'Anna, Salvatore A.

AU - Weiland, James D.

AU - Grebe, Rhonda R.

AU - Grebe, Lynnea

AU - Fujii, Gildo

AU - Kim, Sahng Yeon

AU - Greenberg, Robert J.

AU - De Juan, Eugene

AU - Humayun, Mark S.

PY - 2003/3/1

Y1 - 2003/3/1

N2 - BACKGROUND AND OBJECTIVE: To study the heat and power dissipation effect of an intraocular electronic heater on the retina. The determination of thermal parameters that are nonharmful to the retina will aid in the development of an implantable intraocular electronic retinal prosthesis. MATERIALS AND METHODS: In dogs, five different retinal areas were touched with a custom intraocular heater probe (1.4 X 1.4 X 1.0 mm) for 1 second while the heater dissipated 0 (control), 10, 20, 50, or 100 mW. In a second protocol, the heater was mechanically held in the vitreous cavity while dissipating 500 mW for 2 hours while monitoring intraocular temperature. The animals were observed for 4 weeks with serial fundus photography and electroretinography. The procedure was then repeated in the fellow eye. The dogs were killed and both eyes were enucleated and submitted for histology. RESULTS: In experiments using protocol 1, heater settings of 50 mW or higher caused an immediate visible whitening of the retinal tissue. Histologically, this damage was evident only if the eyes were immediately enucleated. Permanent damage was caused by heater settings of 100 mW or higher. Under protocol 2, no ophthalmologic, electroretinography, or histologic differences were noted between the groups. Temperature increases of 5°C in the vitreous and 2°C near the retina were noted. CONCLUSIONS: The liquid environment of the eye acts as a heat sink that is capable of dissipating a significant amount of power. An electronic chip positioned away from the retina can run at considerably higher powers than a chip positioned on the retinal surface.

AB - BACKGROUND AND OBJECTIVE: To study the heat and power dissipation effect of an intraocular electronic heater on the retina. The determination of thermal parameters that are nonharmful to the retina will aid in the development of an implantable intraocular electronic retinal prosthesis. MATERIALS AND METHODS: In dogs, five different retinal areas were touched with a custom intraocular heater probe (1.4 X 1.4 X 1.0 mm) for 1 second while the heater dissipated 0 (control), 10, 20, 50, or 100 mW. In a second protocol, the heater was mechanically held in the vitreous cavity while dissipating 500 mW for 2 hours while monitoring intraocular temperature. The animals were observed for 4 weeks with serial fundus photography and electroretinography. The procedure was then repeated in the fellow eye. The dogs were killed and both eyes were enucleated and submitted for histology. RESULTS: In experiments using protocol 1, heater settings of 50 mW or higher caused an immediate visible whitening of the retinal tissue. Histologically, this damage was evident only if the eyes were immediately enucleated. Permanent damage was caused by heater settings of 100 mW or higher. Under protocol 2, no ophthalmologic, electroretinography, or histologic differences were noted between the groups. Temperature increases of 5°C in the vitreous and 2°C near the retina were noted. CONCLUSIONS: The liquid environment of the eye acts as a heat sink that is capable of dissipating a significant amount of power. An electronic chip positioned away from the retina can run at considerably higher powers than a chip positioned on the retinal surface.

UR - http://www.scopus.com/inward/record.url?scp=0037361332&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037361332&partnerID=8YFLogxK

M3 - Article

VL - 34

SP - 114

EP - 120

JO - Ophthalmic Surgery Lasers and Imaging Retina

JF - Ophthalmic Surgery Lasers and Imaging Retina

SN - 2325-8160

IS - 2

ER -