Abstract

Permanent orthopedic implants made from titanium, stainless steel, or cobalt-chromium alloys cause stress shielding and lead to secondary surgery. Biodegradable magnesium-calcium (MgCa) alloys have the potential to minimize stress shielding as well as eliminate the need for secondary surgery. The critical technical challenge is that magnesium degrades rapidly in the human body. In order to slow the corrosion rate, surface treatments such as laser shock peening (LSP), shot peening, or burnishing have been reported in literature. Each of these surface treatments uniquely alters the surface integrity and consequent fatigue life. Even though surface treatments may be effective at slowing corrosion rates, it is important to ensure that they do not shorten fatigue life. The purpose of this study was to (1) develop a laser shock peening (LSP) surface treatment of a curved surface that adjusts the surface integrity of a MgCa alloy by varying the peening overlap ratio and (2) determine the effect of LSP on the fatigue life. Surface integrity was characterized by topography, microstructure, and microhardness. Fatigue life of laser peened and unpeened samples were measured by rotating bending fatigue tests. It was found that LSP increased the fatigue life of the peened MgCa samples. Implementing LSP at high overlap ratios reduced the surface pile-up which resulted in a higher fatigue life. The fractured surfaces of the peened samples exhibited striation patterns which were more pronounced at higher peening overlap ratios.

Original languageEnglish (US)
Pages (from-to)428-436
Number of pages9
JournalInternational Journal of Fatigue
Volume82
DOIs
StatePublished - Jan 2016

Fingerprint

Calcium alloys
Shot peening
Implant
Magnesium
Orthopedics
Fatigue Life
Magnesium alloys
Calcium
Fatigue
Surface Treatment
Shock
Fatigue of materials
Laser
Lasers
Surface treatment
Integrity
Overlap
Corrosion
Surgery
Corrosion rate

Keywords

  • Biodegradable implant
  • Fatigue
  • Laser shock peening
  • Magnesium
  • Surface treatment

ASJC Scopus subject areas

  • Modeling and Simulation
  • Materials Science(all)
  • Mechanics of Materials
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering

Cite this

Fatigue performance of biodegradable magnesium-calcium alloy processed by laser shock peening for orthopedic implants. / Sealy, M. P.; Guo, Y. B.; Caslaru, R. C.; Sharkins, J.; Feldman, D.

In: International Journal of Fatigue, Vol. 82, 01.2016, p. 428-436.

Research output: Contribution to journalArticle

@article{70d508369f0f4fbdb0abd134f8cab5a0,
title = "Fatigue performance of biodegradable magnesium-calcium alloy processed by laser shock peening for orthopedic implants",
abstract = "Permanent orthopedic implants made from titanium, stainless steel, or cobalt-chromium alloys cause stress shielding and lead to secondary surgery. Biodegradable magnesium-calcium (MgCa) alloys have the potential to minimize stress shielding as well as eliminate the need for secondary surgery. The critical technical challenge is that magnesium degrades rapidly in the human body. In order to slow the corrosion rate, surface treatments such as laser shock peening (LSP), shot peening, or burnishing have been reported in literature. Each of these surface treatments uniquely alters the surface integrity and consequent fatigue life. Even though surface treatments may be effective at slowing corrosion rates, it is important to ensure that they do not shorten fatigue life. The purpose of this study was to (1) develop a laser shock peening (LSP) surface treatment of a curved surface that adjusts the surface integrity of a MgCa alloy by varying the peening overlap ratio and (2) determine the effect of LSP on the fatigue life. Surface integrity was characterized by topography, microstructure, and microhardness. Fatigue life of laser peened and unpeened samples were measured by rotating bending fatigue tests. It was found that LSP increased the fatigue life of the peened MgCa samples. Implementing LSP at high overlap ratios reduced the surface pile-up which resulted in a higher fatigue life. The fractured surfaces of the peened samples exhibited striation patterns which were more pronounced at higher peening overlap ratios.",
keywords = "Biodegradable implant, Fatigue, Laser shock peening, Magnesium, Surface treatment",
author = "Sealy, {M. P.} and Guo, {Y. B.} and Caslaru, {R. C.} and J. Sharkins and D. Feldman",
year = "2016",
month = "1",
doi = "10.1016/j.ijfatigue.2015.08.024",
language = "English (US)",
volume = "82",
pages = "428--436",
journal = "International Journal of Fatigue",
issn = "0142-1123",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Fatigue performance of biodegradable magnesium-calcium alloy processed by laser shock peening for orthopedic implants

AU - Sealy, M. P.

AU - Guo, Y. B.

AU - Caslaru, R. C.

AU - Sharkins, J.

AU - Feldman, D.

PY - 2016/1

Y1 - 2016/1

N2 - Permanent orthopedic implants made from titanium, stainless steel, or cobalt-chromium alloys cause stress shielding and lead to secondary surgery. Biodegradable magnesium-calcium (MgCa) alloys have the potential to minimize stress shielding as well as eliminate the need for secondary surgery. The critical technical challenge is that magnesium degrades rapidly in the human body. In order to slow the corrosion rate, surface treatments such as laser shock peening (LSP), shot peening, or burnishing have been reported in literature. Each of these surface treatments uniquely alters the surface integrity and consequent fatigue life. Even though surface treatments may be effective at slowing corrosion rates, it is important to ensure that they do not shorten fatigue life. The purpose of this study was to (1) develop a laser shock peening (LSP) surface treatment of a curved surface that adjusts the surface integrity of a MgCa alloy by varying the peening overlap ratio and (2) determine the effect of LSP on the fatigue life. Surface integrity was characterized by topography, microstructure, and microhardness. Fatigue life of laser peened and unpeened samples were measured by rotating bending fatigue tests. It was found that LSP increased the fatigue life of the peened MgCa samples. Implementing LSP at high overlap ratios reduced the surface pile-up which resulted in a higher fatigue life. The fractured surfaces of the peened samples exhibited striation patterns which were more pronounced at higher peening overlap ratios.

AB - Permanent orthopedic implants made from titanium, stainless steel, or cobalt-chromium alloys cause stress shielding and lead to secondary surgery. Biodegradable magnesium-calcium (MgCa) alloys have the potential to minimize stress shielding as well as eliminate the need for secondary surgery. The critical technical challenge is that magnesium degrades rapidly in the human body. In order to slow the corrosion rate, surface treatments such as laser shock peening (LSP), shot peening, or burnishing have been reported in literature. Each of these surface treatments uniquely alters the surface integrity and consequent fatigue life. Even though surface treatments may be effective at slowing corrosion rates, it is important to ensure that they do not shorten fatigue life. The purpose of this study was to (1) develop a laser shock peening (LSP) surface treatment of a curved surface that adjusts the surface integrity of a MgCa alloy by varying the peening overlap ratio and (2) determine the effect of LSP on the fatigue life. Surface integrity was characterized by topography, microstructure, and microhardness. Fatigue life of laser peened and unpeened samples were measured by rotating bending fatigue tests. It was found that LSP increased the fatigue life of the peened MgCa samples. Implementing LSP at high overlap ratios reduced the surface pile-up which resulted in a higher fatigue life. The fractured surfaces of the peened samples exhibited striation patterns which were more pronounced at higher peening overlap ratios.

KW - Biodegradable implant

KW - Fatigue

KW - Laser shock peening

KW - Magnesium

KW - Surface treatment

UR - http://www.scopus.com/inward/record.url?scp=84946422841&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84946422841&partnerID=8YFLogxK

U2 - 10.1016/j.ijfatigue.2015.08.024

DO - 10.1016/j.ijfatigue.2015.08.024

M3 - Article

AN - SCOPUS:84946422841

VL - 82

SP - 428

EP - 436

JO - International Journal of Fatigue

JF - International Journal of Fatigue

SN - 0142-1123

ER -