Fabrication and characterization of medical grade polyurethane composite catheters for near-infrared imaging

André T. Stevenson, Laura M. Reese, Tanner K. Hill, Jeffrey McGuire, Aaron M. Mohs, Raj Shekhar, Lissett R. Bickford, Abby R. Whittington

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

Peripherally inserted central catheters (PICCs) are hollow polymeric tubes that transport nutrients, blood and medications to neonates. To determine proper PICC placement, frequent X-ray imaging of neonates is performed. Because X-rays pose severe health risks to neonates, safer alternatives are needed. We hypothesize that near infrared (NIR) polymer composites can be fabricated into catheters by incorporating a fluorescent dye (IRDye 800CW) and visualized using NIR imaging. To fabricate catheters, polymer and dye are dry mixed and pressed, sectioned, and extruded to produce hollow tubes. We analyzed surface roughness, stiffness, dye retention, NIR contrast intensity, and biocompatibility. The extrusion process did not significantly alter the mechanical properties of the polymer composites. Over a period of 23 days, only 6.35±5.08% dye leached out of catheters. The addition of 0.025wt% dye resulted in a 14-fold contrast enhancement producing clear PICC images at 1cm under a tissue equivalent. The addition of IRDye 800CW did not alter the biocompatibility of the polymer and did not increase adhesion of cells to the surface. We successfully demonstrated that catheters can be imaged without the use of harmful radiation and still maintain the same properties as the unaltered medical grade equivalent.

Original languageEnglish (US)
Pages (from-to)168-176
Number of pages9
JournalBiomaterials
Volume54
DOIs
StatePublished - Jun 1 2015

Fingerprint

Polyurethanes
Catheters
Infrared imaging
Fabrication
Dyes
Composite materials
Polymers
Coloring Agents
Biocompatibility
X-Rays
Infrared radiation
X rays
Health risks
Fluorescent Dyes
Cell Adhesion
Nutrients
Extrusion
Blood
Adhesion
Surface roughness

Keywords

  • Catheter
  • Cell adhesion
  • Fluorescence
  • Mechanical testing
  • Polyurethane

ASJC Scopus subject areas

  • Bioengineering
  • Ceramics and Composites
  • Biophysics
  • Biomaterials
  • Mechanics of Materials

Cite this

Fabrication and characterization of medical grade polyurethane composite catheters for near-infrared imaging. / Stevenson, André T.; Reese, Laura M.; Hill, Tanner K.; McGuire, Jeffrey; Mohs, Aaron M.; Shekhar, Raj; Bickford, Lissett R.; Whittington, Abby R.

In: Biomaterials, Vol. 54, 01.06.2015, p. 168-176.

Research output: Contribution to journalArticle

Stevenson, AT, Reese, LM, Hill, TK, McGuire, J, Mohs, AM, Shekhar, R, Bickford, LR & Whittington, AR 2015, 'Fabrication and characterization of medical grade polyurethane composite catheters for near-infrared imaging', Biomaterials, vol. 54, pp. 168-176. https://doi.org/10.1016/j.biomaterials.2015.03.020
Stevenson, André T. ; Reese, Laura M. ; Hill, Tanner K. ; McGuire, Jeffrey ; Mohs, Aaron M. ; Shekhar, Raj ; Bickford, Lissett R. ; Whittington, Abby R. / Fabrication and characterization of medical grade polyurethane composite catheters for near-infrared imaging. In: Biomaterials. 2015 ; Vol. 54. pp. 168-176.
@article{40e36660eeff4e62840e360add2020ed,
title = "Fabrication and characterization of medical grade polyurethane composite catheters for near-infrared imaging",
abstract = "Peripherally inserted central catheters (PICCs) are hollow polymeric tubes that transport nutrients, blood and medications to neonates. To determine proper PICC placement, frequent X-ray imaging of neonates is performed. Because X-rays pose severe health risks to neonates, safer alternatives are needed. We hypothesize that near infrared (NIR) polymer composites can be fabricated into catheters by incorporating a fluorescent dye (IRDye 800CW) and visualized using NIR imaging. To fabricate catheters, polymer and dye are dry mixed and pressed, sectioned, and extruded to produce hollow tubes. We analyzed surface roughness, stiffness, dye retention, NIR contrast intensity, and biocompatibility. The extrusion process did not significantly alter the mechanical properties of the polymer composites. Over a period of 23 days, only 6.35±5.08{\%} dye leached out of catheters. The addition of 0.025wt{\%} dye resulted in a 14-fold contrast enhancement producing clear PICC images at 1cm under a tissue equivalent. The addition of IRDye 800CW did not alter the biocompatibility of the polymer and did not increase adhesion of cells to the surface. We successfully demonstrated that catheters can be imaged without the use of harmful radiation and still maintain the same properties as the unaltered medical grade equivalent.",
keywords = "Catheter, Cell adhesion, Fluorescence, Mechanical testing, Polyurethane",
author = "Stevenson, {Andr{\'e} T.} and Reese, {Laura M.} and Hill, {Tanner K.} and Jeffrey McGuire and Mohs, {Aaron M.} and Raj Shekhar and Bickford, {Lissett R.} and Whittington, {Abby R.}",
year = "2015",
month = "6",
day = "1",
doi = "10.1016/j.biomaterials.2015.03.020",
language = "English (US)",
volume = "54",
pages = "168--176",
journal = "Biomaterials",
issn = "0142-9612",
publisher = "Elsevier BV",

}

TY - JOUR

T1 - Fabrication and characterization of medical grade polyurethane composite catheters for near-infrared imaging

AU - Stevenson, André T.

AU - Reese, Laura M.

AU - Hill, Tanner K.

AU - McGuire, Jeffrey

AU - Mohs, Aaron M.

AU - Shekhar, Raj

AU - Bickford, Lissett R.

AU - Whittington, Abby R.

PY - 2015/6/1

Y1 - 2015/6/1

N2 - Peripherally inserted central catheters (PICCs) are hollow polymeric tubes that transport nutrients, blood and medications to neonates. To determine proper PICC placement, frequent X-ray imaging of neonates is performed. Because X-rays pose severe health risks to neonates, safer alternatives are needed. We hypothesize that near infrared (NIR) polymer composites can be fabricated into catheters by incorporating a fluorescent dye (IRDye 800CW) and visualized using NIR imaging. To fabricate catheters, polymer and dye are dry mixed and pressed, sectioned, and extruded to produce hollow tubes. We analyzed surface roughness, stiffness, dye retention, NIR contrast intensity, and biocompatibility. The extrusion process did not significantly alter the mechanical properties of the polymer composites. Over a period of 23 days, only 6.35±5.08% dye leached out of catheters. The addition of 0.025wt% dye resulted in a 14-fold contrast enhancement producing clear PICC images at 1cm under a tissue equivalent. The addition of IRDye 800CW did not alter the biocompatibility of the polymer and did not increase adhesion of cells to the surface. We successfully demonstrated that catheters can be imaged without the use of harmful radiation and still maintain the same properties as the unaltered medical grade equivalent.

AB - Peripherally inserted central catheters (PICCs) are hollow polymeric tubes that transport nutrients, blood and medications to neonates. To determine proper PICC placement, frequent X-ray imaging of neonates is performed. Because X-rays pose severe health risks to neonates, safer alternatives are needed. We hypothesize that near infrared (NIR) polymer composites can be fabricated into catheters by incorporating a fluorescent dye (IRDye 800CW) and visualized using NIR imaging. To fabricate catheters, polymer and dye are dry mixed and pressed, sectioned, and extruded to produce hollow tubes. We analyzed surface roughness, stiffness, dye retention, NIR contrast intensity, and biocompatibility. The extrusion process did not significantly alter the mechanical properties of the polymer composites. Over a period of 23 days, only 6.35±5.08% dye leached out of catheters. The addition of 0.025wt% dye resulted in a 14-fold contrast enhancement producing clear PICC images at 1cm under a tissue equivalent. The addition of IRDye 800CW did not alter the biocompatibility of the polymer and did not increase adhesion of cells to the surface. We successfully demonstrated that catheters can be imaged without the use of harmful radiation and still maintain the same properties as the unaltered medical grade equivalent.

KW - Catheter

KW - Cell adhesion

KW - Fluorescence

KW - Mechanical testing

KW - Polyurethane

UR - http://www.scopus.com/inward/record.url?scp=84928028737&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84928028737&partnerID=8YFLogxK

U2 - 10.1016/j.biomaterials.2015.03.020

DO - 10.1016/j.biomaterials.2015.03.020

M3 - Article

C2 - 25907050

AN - SCOPUS:84928028737

VL - 54

SP - 168

EP - 176

JO - Biomaterials

JF - Biomaterials

SN - 0142-9612