External beam planning module of Eclipse for external beam radiation therapy

Cheng B. Saw, Si Cong Li, Frank Battin, Janice McKeague, Christopher A. Peters

Research output: Contribution to journalReview article

1 Citation (Scopus)

Abstract

Eclipse is a 3-dimensional (3D) treatment planning system for radiation therapy offered by Varian Medical Systems, Inc. The system has the network connectivity for the electronic transfer of image datasets and digital data communication among different equipment. The scope of this project for this special issue of Medical Dosimetry on 3D treatment planning systems is the assessment of planning tools in the external beam planning module of Eclipse to generate optimized treatment plans for patients undergoing external beam radiation therapy. This treatment planning system is relatively mature to be able to generate (1) simple treatment plans, (2) conformal radiation therapy plans, (3) static intensity-modulated radiation therapy (IMRT) plans, (4) volumetric-modulated arc therapy (VMAT) plans, and (5) treatment plans for electron beam therapy. The treatment planning tools are relatively plentiful to assist in the radiation therapy treatment planning. Some new features have been incorporated in the latest version and are helpful for making high-quality treatment plans. However, the location of the tools is not intuitive, and hence, familiarity with the user interface is essential to the efficient use of the treatment planning system. In addition, there are a number of dose algorithms available for the computation of dose distributions. The understanding of each dose computation algorithm is essential for the optimal use of this treatment planning system.

Original languageEnglish (US)
Pages (from-to)195-204
Number of pages10
JournalMedical Dosimetry
Volume43
Issue number2
DOIs
StatePublished - Jun 1 2018

Fingerprint

Radiotherapy
Therapeutics
Intensity-Modulated Radiotherapy
Communication
Electrons
Equipment and Supplies

Keywords

  • Conformal radiation therapy
  • Electron beam therapy
  • Intensity-modulated radiation therapy
  • Radiation treatment planning
  • Treatment planning systems
  • Volumetric-modulated arc therapy

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Cite this

External beam planning module of Eclipse for external beam radiation therapy. / Saw, Cheng B.; Li, Si Cong; Battin, Frank; McKeague, Janice; Peters, Christopher A.

In: Medical Dosimetry, Vol. 43, No. 2, 01.06.2018, p. 195-204.

Research output: Contribution to journalReview article

Saw, Cheng B. ; Li, Si Cong ; Battin, Frank ; McKeague, Janice ; Peters, Christopher A. / External beam planning module of Eclipse for external beam radiation therapy. In: Medical Dosimetry. 2018 ; Vol. 43, No. 2. pp. 195-204.
@article{7e99e6e8136642f3920b35bb07bdb34f,
title = "External beam planning module of Eclipse for external beam radiation therapy",
abstract = "Eclipse is a 3-dimensional (3D) treatment planning system for radiation therapy offered by Varian Medical Systems, Inc. The system has the network connectivity for the electronic transfer of image datasets and digital data communication among different equipment. The scope of this project for this special issue of Medical Dosimetry on 3D treatment planning systems is the assessment of planning tools in the external beam planning module of Eclipse to generate optimized treatment plans for patients undergoing external beam radiation therapy. This treatment planning system is relatively mature to be able to generate (1) simple treatment plans, (2) conformal radiation therapy plans, (3) static intensity-modulated radiation therapy (IMRT) plans, (4) volumetric-modulated arc therapy (VMAT) plans, and (5) treatment plans for electron beam therapy. The treatment planning tools are relatively plentiful to assist in the radiation therapy treatment planning. Some new features have been incorporated in the latest version and are helpful for making high-quality treatment plans. However, the location of the tools is not intuitive, and hence, familiarity with the user interface is essential to the efficient use of the treatment planning system. In addition, there are a number of dose algorithms available for the computation of dose distributions. The understanding of each dose computation algorithm is essential for the optimal use of this treatment planning system.",
keywords = "Conformal radiation therapy, Electron beam therapy, Intensity-modulated radiation therapy, Radiation treatment planning, Treatment planning systems, Volumetric-modulated arc therapy",
author = "Saw, {Cheng B.} and Li, {Si Cong} and Frank Battin and Janice McKeague and Peters, {Christopher A.}",
year = "2018",
month = "6",
day = "1",
doi = "10.1016/j.meddos.2018.03.003",
language = "English (US)",
volume = "43",
pages = "195--204",
journal = "Medical Dosimetry",
issn = "0958-3947",
publisher = "Elsevier Inc.",
number = "2",

}

TY - JOUR

T1 - External beam planning module of Eclipse for external beam radiation therapy

AU - Saw, Cheng B.

AU - Li, Si Cong

AU - Battin, Frank

AU - McKeague, Janice

AU - Peters, Christopher A.

PY - 2018/6/1

Y1 - 2018/6/1

N2 - Eclipse is a 3-dimensional (3D) treatment planning system for radiation therapy offered by Varian Medical Systems, Inc. The system has the network connectivity for the electronic transfer of image datasets and digital data communication among different equipment. The scope of this project for this special issue of Medical Dosimetry on 3D treatment planning systems is the assessment of planning tools in the external beam planning module of Eclipse to generate optimized treatment plans for patients undergoing external beam radiation therapy. This treatment planning system is relatively mature to be able to generate (1) simple treatment plans, (2) conformal radiation therapy plans, (3) static intensity-modulated radiation therapy (IMRT) plans, (4) volumetric-modulated arc therapy (VMAT) plans, and (5) treatment plans for electron beam therapy. The treatment planning tools are relatively plentiful to assist in the radiation therapy treatment planning. Some new features have been incorporated in the latest version and are helpful for making high-quality treatment plans. However, the location of the tools is not intuitive, and hence, familiarity with the user interface is essential to the efficient use of the treatment planning system. In addition, there are a number of dose algorithms available for the computation of dose distributions. The understanding of each dose computation algorithm is essential for the optimal use of this treatment planning system.

AB - Eclipse is a 3-dimensional (3D) treatment planning system for radiation therapy offered by Varian Medical Systems, Inc. The system has the network connectivity for the electronic transfer of image datasets and digital data communication among different equipment. The scope of this project for this special issue of Medical Dosimetry on 3D treatment planning systems is the assessment of planning tools in the external beam planning module of Eclipse to generate optimized treatment plans for patients undergoing external beam radiation therapy. This treatment planning system is relatively mature to be able to generate (1) simple treatment plans, (2) conformal radiation therapy plans, (3) static intensity-modulated radiation therapy (IMRT) plans, (4) volumetric-modulated arc therapy (VMAT) plans, and (5) treatment plans for electron beam therapy. The treatment planning tools are relatively plentiful to assist in the radiation therapy treatment planning. Some new features have been incorporated in the latest version and are helpful for making high-quality treatment plans. However, the location of the tools is not intuitive, and hence, familiarity with the user interface is essential to the efficient use of the treatment planning system. In addition, there are a number of dose algorithms available for the computation of dose distributions. The understanding of each dose computation algorithm is essential for the optimal use of this treatment planning system.

KW - Conformal radiation therapy

KW - Electron beam therapy

KW - Intensity-modulated radiation therapy

KW - Radiation treatment planning

KW - Treatment planning systems

KW - Volumetric-modulated arc therapy

UR - http://www.scopus.com/inward/record.url?scp=85046788627&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85046788627&partnerID=8YFLogxK

U2 - 10.1016/j.meddos.2018.03.003

DO - 10.1016/j.meddos.2018.03.003

M3 - Review article

C2 - 29753335

AN - SCOPUS:85046788627

VL - 43

SP - 195

EP - 204

JO - Medical Dosimetry

JF - Medical Dosimetry

SN - 0958-3947

IS - 2

ER -